• 제목/요약/키워드: Infrared analysis system

검색결과 432건 처리시간 0.029초

Thermo-tracer를 이용한 온실의 열환경 분석 (Thermal environment analysis of greenhouse using Thermo-tracer)

  • 이석건;이종원;이현우;김란숙
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.230-236
    • /
    • 1998
  • Thermal environment of greenhouse was investigated by thermo-tracer in this study. The Thermo-tracer is a high-sensitivity infrared thermometer of non-contact type. The infrared energy emitted from the measured object is converted into an electrical signal by the detector(HgCdTe) and display as a color or black & white thermal image by way of optical scanning, The experiment was conducted for Venlo-type greenhouse with pad & fan system. The temperature difference between measured by Thermo-trace and measured by HOBO sensor is maximum 0.8$^{\circ}C$. Thermo-trace is possible to use for the thermal environment analysis and diagnosis of a cooling and heating system of greenhouse.

  • PDF

레이저 브레이징에서의 열유동 해석에 관한 연구 (A Study on Analysis of Heat Flow in Laser Brazing)

  • 전민규;김원배;한국찬;나석주
    • Journal of Welding and Joining
    • /
    • 제13권3호
    • /
    • pp.96-105
    • /
    • 1995
  • An advantage offered by brazing over fusion welding is that strong joints may be produced at relatively low heat input. To minimize the thermal effects and maintain the desired dimension of assemblies. the CO$_{2}$ laser beam can be applied to the brazed joint of pin and plate as a micro heat source. This paper presents a analysis model of the laser brazing process considering the laser beam mode and heat flow in brazed parts by using the finite element method. The simulation results were compared with the experimental results obtained from the infrared temperature sensing system. Based on these results, the proper process parameters were investigated to get a good joining quality. The influence of the beam mode change was examined with respect to the temperature distribution and joint quality.

  • PDF

Athermal Design and Performance Verification of an LWIR Zoom Lens for Drones

  • Kwang-Woo Park;Sung-Chan Park
    • Current Optics and Photonics
    • /
    • 제8권4호
    • /
    • pp.366-374
    • /
    • 2024
  • This paper presents an optimum method for determining the parameters to athermalize a long-wavelength infrared (LWIR) zoom camera by introducing the defocus sensitivity analysis. To effectively find parameters that significantly affect thermal defocus, we simulated athermal analysis with temperature changes for all variables. Consequently, we found that the optimum parameter to correct thermal defocus is the compensation lens, and its movements with temperature at each zoom position are obtained from the simulated athermal analysis. To verify the efficiency of our athermal approach, we performed actual athermal tests in a broad temperature range at each zoom position. The simulated athermal analysis provides the initial position of the compensation lens at the corresponding temperature and zoom position. Then the compensation lens is elaboratively moved to serve the highest live contrast ratio (LCR) for the target. This experiment shows that the compensation lens locations in the actual test are closely matched to those in the simulated athermal analysis. In addition, two outdoor tests conducted in two different environments confirm that the autofocus system suggested in this study performs well at all zoom positions. Using the proposed athermal analysis approach in this paper, we efficiently realize an athermal system over the specified temperature and zoom ranges.

복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극 (An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber)

  • 김영민;박성제;강병하
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

근적외분광분석법을 이용한 과산화수소의 농도 측정 (Determination of Hydrogen Peroxide Concentration by Portable Near-Infrared (NIR) System)

  • 임현량;우영아;장수현;김경미;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.324-330
    • /
    • 2002
  • This experiment was carried out to determine non-destructively the hydrogen peroxide concentration of 3% antiseptic hydrogen peroxide solutions by portable near-infrared (NIR) system. Hydrogen peroxide standards were prepared ranging from 0 to 25.6 w/w% and the NIR spectra of hydrogen peroxide standard solutions were collected by using a quartz cell in 1 mm pathlength. We found the variation of absorbance band due to OH vibration of hydrogen peroxide depending on the concentration around 1400 nm in the second derivatives spectra. Partial least square regression (PLSR) and multilinear regression (MLR) were explored to develop a calibration model over the spectral range 1100-1720 nm. The model using PLSR was better than that using MLR. The calibration showed good results with a standard error of prediction (SEP) of 0.16%. In order to validate the developed calibration model, routine analyses were performed using commercial antiseptic hydrogen peroxide solutions. The hydrogen peroxide values from the NIR calibration model were compared with the values from a redox titration method. The NIR routine analyses results showed good correlation with those of the redox titration method. This study showed that the rapid and non-destructive determination of hydrogen peroxide in the antiseptic solution was successfully performed by portable NIR system without very harmful solvents.

회절광학을 이용한 적외선 광학계 설계 및 BSP를 이용한 성능 평가, 분석 (Design and Analysis of Infrared Diffractive Optical Systems Using Beam Synthesis Propagation)

  • 공현배;조두진
    • 한국광학회지
    • /
    • 제24권4호
    • /
    • pp.189-195
    • /
    • 2013
  • 본 논문에서는 두 매의 BD-2 렌즈와 비구면 회절 광학을 포함하는 F/1.2, 시야각 $15.2^{\circ}$$8-14{\mu}m$의 원적외선 파장대역을 가지는 광학계를 설계하였다. 이 광학계는 uncooled camera에 사용될 수 있으며, 광학계의 분석은 BSP로 진행되었다. 회절광학은 주어진 두께를 가지는 물리적인 면으로 취급하였으며, 분석결과를 출사동공법과 같은 기존 방법들에 의한 것과 회절차수 합성법에 의한 것과 비교하였다.

지향성 적외선 방해장치 성능분석을 위한 위협체모사기 구축에 관한 연구 (Research on the Implementation of Infrared Threat Surrogate for DIRCM Performance Analysis)

  • 천승우;김희정;조수형;김재협;유현근
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권3호
    • /
    • pp.97-106
    • /
    • 2015
  • 본 논문에서는 DIRCM의 개발단계에서 수행하는 기만 성능검증을 위한 시뮬레이터인 위협체모사기 구축에 관한 내용에 대해 기술한다. 기존의 PC기반의 성능분석 시뮬레이터와 달리 본 연구에서 개발된 위협체모사기는 DIRCM의 레이저를 실제 운용하는 거리에서 직접 조사하는 방식으로 실제 환경에서 기만효과를 정확히 분석 할 수 있다. 또한, 실험실에서 시준기를 통해 레이저를 조사하는 방식의 기만효과 시험도 가능하도록 개발하여 기만코드 개발에 필요한 시간과 비용을 절약할 수 있도록 하였다. 본 연구에서 개발한 위협체모사기는 실제 1,2세대 탐색기와 같은 F넘버와 같은 구조의 반사광학계로 개발하였다. 그리고 코드재밍 기법에 대한 성능분석 기능과 4세대 이상의 탐색기에 적용되는 면형검출기의 포화기만 분석도 가능한 구조로 개발하였다. 실험결과, 1,2세대 모의위협체는 정확한 추적성능과 기만효과를 나타내었다.

위상잠금 열영상 현미경의 온도분해능 분석 (Thermal Resolution Analysis of Lock-in Infrared Microscope)

  • 김기석;이계승;김건희;허환;김동익;장기수
    • 비파괴검사학회지
    • /
    • 제35권1호
    • /
    • pp.12-17
    • /
    • 2015
  • 본 연구에서는 기존의 열영상 측정 장치에 비해 위상잠금기법을 채용한 열영상 측정 장치의 온도분해능이 얼마나 향상될 수 있는지를 평가하기 위해 흑체시스템과 마이크로 레지스터 시편을 이용한 실험을 수행하여 개선된 온도분해능을 확인하였다. 일반적으로 적외선 열영상 측정 장치의 노이즈 수준 또는 온도분해능은 연속적으로 측정된 열영상의 픽셀별 온도의 평균과 각각의 측정값의 편차에 대한 제곱의 평균으로 정의되는 잡음등가온도차(noise equivalent temperature difference, NETD)라는 척도를 이용하여 평가되고 있다. 하지만 위상잠금 열영상 기법을 적용하면 더욱 편리한 방법을 이용할 수 있는데 이는 측정된 열영상 신호의 위상과는 무관한 온도의 진폭에 관한 정보를 이용하는 것이다. 연구결과를 통해 알 수 있듯이, 위상잠금 기법을 적용하게 되면 측정된 신호의 온도분해능 성능을 보여주는 잡음등가온도차가 크게 향상되었으며 이는 위상잠금기법이 내부적으로 수행하는 평균화 작업과 필터링 기능 때문인 것으로 판단되고 있다.

적외선 우주망원경 냉각시스템 시험모델 열설계 (THERMAL DESIGN OF A PROTOMODEL SPACE INFRARED CRYOGENIC SYSTEM)

  • 양형석;김동락;이병섭;김건희;이대희;박수종;남욱원
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권2호
    • /
    • pp.153-160
    • /
    • 2006
  • 이 논문에서는 적외선 우주관측을 위한 냉각시스템 시험모델(PSICS, Protomodel Space Infrared Cryogenic System)의 설계를 위해 수행된 열해석 및 열설계 내용을 논의한다. 이 냉각시스템은 장래 진행될 위성 탑제용 적외선 우주 망원경의 냉각시스템 계발을 위한 예비연구를 위한 시스템이며, 테스트는 지상에서의 관측을 통해 수행된다. 냉각목표 온도는 80K이고, 80K에서 500mW의 냉각능력을 갖는 스터링 냉동기 1대가 냉각에 사용된다. 저열침입과 열부하의 바른 예측을 위해 냉각시스템의 전도, 복사 등의 각 열전달 모드에 대해 열부하를 산출하였고, 총 열부하는 복사열 차단 정도에 따라 $42{\sim}149mW$임을 알았다. 또한 냉각박스 표면의 온도분포는 0.12K 이하의 균일한 온도분포로 유지될 수 있음을 알았다. 이를 통해 80K에서 500mW의 냉동기를 이용하여 충분히 냉각시킬 수 있음을 확인하였다.