• 제목/요약/키워드: Infrared Laser

검색결과 329건 처리시간 0.025초

레이저빔을 이용한 펄스변조 적외선탐색기 기만 (Laser-based Jamming of a Pulse Modulated Infrared Seeker)

  • 김성재;정춘식;신용산
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.179-188
    • /
    • 2019
  • Laser beam is directional and small in divergence angle so that it is well qualified to deliver high intensity infrared energy into a coming MANPADS threat for aircraft survivability. The threat will be deceived and loose tracking of a target when it is exposed to the laser beam modulated relevant to the track mechanism of the threat. The laser beam goes through scattering inside the seeker of the threat and reach the detector in a stray light form, which is a critical phenomenon enabling jamming of the seeker. The mechanism of the laser beam based jamming against a pulse modulated infrared seeker is shown. Simulations are carried out to support the understanding of how the jam technique works.

근적외선 연속발진 레이저 조사에 의한 게르마늄 광학창 손상 연구 (Study of Damage in Germanium Optical Window Irradiated by a Near-infrared Continuous Wave Laser)

  • 이광현;신완순;강응철
    • 한국군사과학기술학회지
    • /
    • 제17권1호
    • /
    • pp.82-89
    • /
    • 2014
  • The damage in germanium (Ge) optical window irradiated by a near-infrared continuous wave (CW) laser was studied. Laser-induced heating and melting process were surveyed, and the specific laser power and the irradiance time to melt were estimated by numerical simulation. The experiments were also carried out to investigate the macro and micro structure change on Ge window. Results showed that the surface deformation was formed by melting and resolidification process, the damaged surface had a polycrystalline phase, and the transmittance as an optical performance factor in mid-infrared region was decreased. We confirmed that an abnormal polycrystalline phase and surface deformation effect such as hillock formation and roughness increase reduced the transmittance of Ge window and were the damage mechanism of CW laser induced damage on Ge window.

실험계획법을 이용한 레이저 산란의 최적 조건 결정에 대한 연구 (A Study on the Optimal Condition Determination of Laser Scattering Using the Design of Experiment)

  • 한재철;김경범
    • 한국정밀공학회지
    • /
    • 제26권7호
    • /
    • pp.58-64
    • /
    • 2009
  • In this paper, an inspection mechanism based on laser scattering has been developed for the surface evaluation of infrared cut-off filters, and optimum conditions of laser scattering are determined using the design of experiment. First of all, attributes and influence factors of laser scattering are investigated and then a laser scattering inspection mechanism is newly designed based on analyses of laser scattering parameters. Also, Taguchi method, one of experimental designs, is used for the optimum condition selection of laser scattering parameters and the optimum condition is determined in order to maximize the detection capability of surface defects. Experiments show that the proposed method is useful in a consistent and effective defect detection and can be applied to surface evaluation processes in manufacturing.

Near-infrared Laser Energy Transmission through Teeth with Crack Lines: An In-vitro Study

  • Sapra, Ashita;Darbar, Arun;George, Roy
    • Medical Lasers
    • /
    • 제10권4호
    • /
    • pp.214-219
    • /
    • 2021
  • Background and Objectives To evaluate the difference in near-infrared (810 nm) laser energy transmission through teeth with and without cracks. Materials and Methods Extracted teeth were sectioned and examined visually for the presence of cracks with the aid of photographs and a trans-illuminator. Fourteen sections, each with cracks (Group A) and no cracks (Group B) were identified and placed 15 mm from the tip of a 300 micron fiber, prior to activation with an 810 nm diode laser (0.1W, 50 ms interval,100 ms duration). A power meter positioned behind the tooth recorded the average energy that was transmitted through the samples. Unpaired t-test analysis was used to determine if the tooth sections with cracks allowed higher power passage compared to sound teeth. Results The mean power recording for the cracked teeth (Group A) was significantly greater (p = 0.0005) than that for the non-cracked teeth (Group B). Conclusion Within the limitations of this study, it is evident that significantly higher laser energy passes through teeth with cracks in comparison to teeth without cracks. A recent clinical study has also shown that lasers could be used to assess symptomatic cracked teeth. Hence, further research is required to determine the relative increase in energy required to identify symptomatic cracked teeth.

플륨 모니터링에 의한 SM45C 레이저 용접특성 평가 (Estimation of Laser Welding Behavior of SM45C Steels by Plume Monitoring)

  • 유영태;김재열;노경보;양동조;오용석;임기건;김지환
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.14-21
    • /
    • 2003
  • With the increased use of lasers in industrial welding applications, techniques for monitoring and controlling these processes become increasingly important. It is very important that we understand the dynamic behaviors of the laser induced Plume in welding, because the laser induced plume has considerable effects on welding efficiency and the quality of materials. As the plume fluctuation was associated with keyhole instability, unstable vapor plume indicated the process was unstable and would result in poor welds. An Infrared Thermal-vision Camera can be utilized compensate for incurracies encountered in real-time monitoring during laser welding. We have results that instabilities of plume are closely related with hot cracking and defect of laser welding.

Near-Infrared Laser Stimulation of the Auditory Nerve in Guinea Pigs

  • Guan, Tian;Wang, Jian;Yang, Muqun;Zhu, Kai;Wang, Yong;Nie, Guohui
    • Journal of the Optical Society of Korea
    • /
    • 제20권2호
    • /
    • pp.269-275
    • /
    • 2016
  • This study has investigated the feasibility of 980-nm low-energy pulsed near-infrared laser stimulation to evoke auditory responses, as well as the effects of radiant exposure and pulse duration on auditory responses. In the experiments, a hole was drilled in the basal turn of the cochlea in guinea pigs. An optical fiber with a 980-nm pulsed infrared laser was inserted into the hole, orientating the spiral ganglion cells in the cochlea. To model deafness, the tympanic membrane was mechanically damaged. Acoustically evoked compound action potentials (ACAPs) were recorded before and after deafness, and optically evoked compound action potentials (OCAPs) were recorded after deafness. Similar spatial selectivity between optical and acoustical stimulation was found. In addition, OCAP amplitudes increased with radiant exposure, indicating a photothermal mechanism induced by optical stimulation. Furthermore, at a fixed radiant exposure, OCAP amplitudes decreased as pulse duration increased, suggesting that optical stimulation might be governed by the time duration over which the energy is delivered. Thus, the current experiments have demonstrated that a 980-nm pulsed near-infrared laser with low energy can evoke auditory neural responses similar to those evoked by acoustical stimulation. This approach could be used to develop optical cochlear implants.

적외선 카메라-레이저 공통광학계의 레이저빔 열 영향성 분석 (Analysis of Laser-beam Thermal Effects In an Infrared Camera and Laser Common-path Optical System)

  • 김성재
    • 한국광학회지
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2017
  • 지향성적외선방해장비의 정렬 정밀도를 높히고 중량을 감소시키기 위해 적용된 적외선 카메라-레이저 공통광학계 구조에서 영상 성능 저하를 야기시키는 레이저빔 열 영향성을 분석하였다. 높은 에너지 밀도를 가지는 레이저빔이 광부품에 흡수되면 열이 발생하고 온도가 상승한다. 공통광학계 광부품 표면에서 발생한 열은 시스템 투과율을 감소시켜 적외선 카메라의 영상 품질을 저하시킬 수 있다. 지향성적외선방해장비의 운용개념을 고려하여 파장 $4{\mu}m$, 출력 3 W의 레이저빔이 10초간 미러(알루미늄, 실리카 글래스, 실리콘) 및 렌즈(사파이어, 셀레늄화아연, 실리콘, 게르마늄) 재료에 조사되는 상황을 가정하여 온도 분포를 계산하였다. 계산 결과, 미러 재료로는 실리카 글래스, 렌즈 재료로는 사파이어의 온도 상승이 상대적으로 컸고, 재료 온도 분포에 가장 큰 영향을 미치는 요소는 재료의 레이저빔 흡수율과 열전도도임을 확인하였다. 결론적으로 적외선 카메라-레이저 공통광학계에 사용하는 광부품은 흡수율이 낮고 열전도도가 높은 특성을 갖도록 선정되어야 광부품 온도 상승에 의한 적외선 카메라의 영상 품질 저하를 방지할 수 있다.

연속발진 레이저에 의한 CCD 영상센서의 손상 분석 (Damage Analysis of CCD Image Sensor Irradiated by Continuous Wave Laser)

  • 윤성희;장경영;신완순
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.690-697
    • /
    • 2016
  • EOIS(electro-optical imaging system) is the main target of the laser weapon. Specially, the image sensor will be vulnerable because EOIS focuses the incident laser beam onto the image sensor. Accordingly, the laser-induced damage of the image sensor needs to be identified for the counter-measure against the laser attack. In this study, the laser-induced damage of the CCD image sensor irradiated by the CW(continuous wave) NIR(near infrared) laser was experimentally investigated and mechanisms of those damage occurrences were analyzed. In the experiment, the near infrared CW fiber laser was used as a laser source. As the fluence, which is the product of the irradiance and the irradiation time, increased, the permanent damages such as discoloration and breakdown appeared sequentially. The discoloration occurred when the color filter was damaged and then the breakdown occurred when the photodiode and substrate were damaged. From the experimental results, LIDTs(laser-induced damage thresholds) of damages were roughly determined.