• Title/Summary/Keyword: Information Signal Process

Search Result 1,422, Processing Time 0.029 seconds

Improved Power Estimation Methodology Based on Signal Transition Density Propagation Behavior (신호 전이 밀도 전파 동작에 기초한 향상된 전력 평가 방법의 연구)

  • Kim, Dong-Ho;Woo, Jong-Jung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.8
    • /
    • pp.2520-2527
    • /
    • 2000
  • An improved transition density propagation method for power estimation is proposed. The power estimation for the zero delay model is a proper criteria for the.lower boutldlIry for power consumption. A transition propagation method, including the zero delay model as a lower boundary for power stimation was studied. However, there were some redundancy factors in the process of transition density propagation. Hence this paper will explore the transition density propagation behavior to eliminate the redundancy factors and present theirriprQved estimation methodology for the signal transition density. The experiments show that the proposed method has comparably better estimation accuracy than the conventional methods.

  • PDF

A Study on Transform Coding of Image Signal using Microcomputer (마이크로컴퓨터를 이용한 영상신호의 변환부호화에 관한 연구)

  • 황재정;김종교;이문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.3
    • /
    • pp.197-203
    • /
    • 1986
  • The images which are scanned by CCTV are converted to digital signal and 6502 Microcomputer processes data by Transform coding. Thus data is reduced to $64{ imes}64$pixels and input by outer memory using same address with inner one for the fast process. Hadmard Transform, Weighted Hadamard Transform which is weighted in the center of matrix and Haar Transform are programmed by assembly language and every Transform is dome within one second.

  • PDF

On the Ultra-Wideband Ambiguity Function (초광대역 Ambiguity Function에 관한 연구)

  • 이준용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3C
    • /
    • pp.368-373
    • /
    • 2004
  • Extremely fine tine resolution of ultra-wideband (UWB) signal poses a new problems to the system designer. A reasonable accuracy of the system clock is necessary to process signals with such a high space resolution. A useful way of illustrating the time resolution of a signal is to evaluate the ambiguity function. The ambiguity function for carrierless UWB defined using the time mismatch and time scaling factor as its two parameters. The UWB ambiguity function is evaluated for various signaling schemes of impulse radio.

Research on an Equivalent Wiener-Hopf Equation (등가의 Wiener-Hopf 방정식에 관한 연구)

  • Ahn, Bong-Man;Cho, Ju-Phil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9C
    • /
    • pp.743-748
    • /
    • 2008
  • This paper makes a research on the equivalent Wiener-Hopf equation which can obtain the coefficient of TDL filter on orthogonal input signal in terms of mean square error. Using this result, we can present the coefficient and error of TDL filter directly without inverse orthogonalization process on orthogonal input signal. We make a theoretical analysis on MMSE and show an Wiener-Hopf solution and the proposed equivalent one in mathematical example simultaneously.

Development of Wireless Instrument for Measuring Cattle's Somatic Information for Stockbreeding Automatization(II) - Development of Single-Channel Wireless Instrument for Measuring Sphygmus - (축산자동화를 위한 가축의 생체정보 무선 계측장치 개발(II) - 단일채널 무선 맥박 계측장치 개발 -)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 1992
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of sphygmus in living animals. In meauring sphygmus counting with the single-channel telemety system, a LED-photo transistor sensor showed more sensitivity to the change of blood pressure than a piezo-electric sensor based pressure sensor. The LED-photo transistor sensor resulted ${\pm}1.29%$ of measurement error of sphygmus counting. In the process of transmitting and receiving the blood pressure signal for counting sphygmus, noises were mixed with, and the noises made the counting almost impossible. Auto-correlation analysis technique was applied to the signal data to extract the sphygmus information, and the technique was proved to be very effective.

  • PDF

Switching properties of bivariate Shewhart control charts for monitoring the covariance matrix

  • Gwon, Hyeon Jin;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.6
    • /
    • pp.1593-1600
    • /
    • 2015
  • A control chart is very useful in monitoring various production process. There are many situations in which the simultaneous control of two or more related quality variables is necessary. We construct bivariate Shewhart control charts based on the trace of the product of the estimated variance-covariance matrix and the inverse of the in-control matrix and investigate the properties of bivariate Shewart control charts with VSI procedure for monitoring covariance matrix in term of ATS (Average time to signal) and ANSW (Average number of switch) and probability of switch, ASI (Average sampling interval). Numerical results show that ATS is smaller than ARL. From examining the properties of switching in changing covariances and variances in ${\Sigma}$, ANSW values show that it does not switch frequently and does not matter to use VSI procedure.

The Design for AAF and SMF Integrated Circuits of SCF System (SCF 시스템의 AAF와 SMF 집적화 설계)

  • 조성익;신홍규;김동용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.5
    • /
    • pp.781-786
    • /
    • 1994
  • In this paper, we have proposed the AAF and the SMF design method that consist of continuous time active RC filter to prevent aliasing distortion by the limitation of SCF input signal, and to smooth the output signal wave of it. The designed AAF and SMF using continuous active RC filter are fabricated by ORBIT 2 m CMOS n-well process. And then the experiment characteristics of the integrated AAF and SMF are compared with SPICE simulation results.

  • PDF

On Neural Network Adaptive Equalizers for Digital Communication

  • Hongrui Jiang;Kwak, Kyung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.10A
    • /
    • pp.1639-1644
    • /
    • 2001
  • Two decision feedback equalizer structures employing recurrent neural network (RNN) used for non-linear channels with severe intersymbol interference (ISI) and non-linear distortion are proposed in this paper, which skillfully put the traditional decision feedback structure for linear channels equalization into RNN, replace decision feedback signal with training signal in the learning process and adaptively adjust the learning step. Simulative results of the first type of two new equalizer structures have shown that it has better equalization performances than traditional recurrent neural network equalizer (RNNE) under the same condition.

  • PDF

The Study of Signal Processing Performance using DiffServ in Mobile IPv6 Network Based on IEEE 802.11e (IEEE 802.11e기반 Mobile IPv6망에서 DiffServ를 이용한 신호처리 성능에 관한 연구)

  • Son, Sung-Chan;Cho, Kyung-Cheol;Cho, Byung-Hak
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.338-341
    • /
    • 2005
  • Recently there are increasing needs for Internet and various kinds of contents. These traffics for various contents need more amount of data to provide high-quality information and require various QoS depending on the characteristics of contents. However, current Internet service supports BE (Best Effort) service only, therefore IntServ (Integrated Service) scheme and DiffSserv (Differentiated Service) scheme are represented to support QoS in IP layer. This paper describes new scheme that provides QoS taking into account the traffic characteristics over Mobile IPv6 network based on IEEE 802.11e by decreasing signal process time using traffic class of DiffServ and evaluates the performance through computer simulation.

  • PDF

Testing and Self Calibration of RF Circuit using MEMS Switches

  • Kannan, Sukeshwar;Kim, Bruce;Noh, Seok-Ho;Park, Se-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.882-885
    • /
    • 2011
  • This paper presents testing and self-calibration of RF circuits using MEMS switches to identify process-related defects and out of specification circuits. We have developed a novel multi-tone dither test technique where the test stimulus is generated by modulating the RF carrier signal with a multi-tone signal generated using an Arbitrary Waveform Generator (AWG) with additive white Gaussian noise. This test stimulus is provided as input to the RF circuit and peak-to-average ratio (PAR) is measured at the output. For a faulty circuit, a significant difference is observed in the value of PAR as compared to a fault-free circuit. Simulation is performed for various circuit conditions such as fault-free as well as fault-induced and their corresponding PARs are stored in the look-up table. This testing and self-calibration technique is exhaustive and efficient for present-day communication systems.

  • PDF