• Title/Summary/Keyword: Information Error

Search Result 11,131, Processing Time 0.04 seconds

The Determinants of New Supply in the Seoul Office Market and their Dynamic Relationship (서울 오피스 신규 공급 결정요인과 동태적 관계분석)

  • Yang, Hye-Seon;Kang, Chang-Deok
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.159-174
    • /
    • 2017
  • The long-term imbalances between supply and demand in office market can weaken urban growth since excessive supply of offices led to office market instability and excessive demand of offices weakens growth of urban industry. Recently, there have been a lot of new large-scale supplies, which increased volatility in Seoul office market. Nevertheless, new supply of Seoul office has not been fully examined. Given this, the focus of this article was on confirming the influences of profitability, replacement cost, and demand on new office supplies in Seoul. In examining those influences, another focus was on their relative influences over time. For these purposes, we analyzed quarterly data of Seoul office market between 2003 and 2015 using a vector error correction model (VECM). As a result, in terms of the influences on the current new supply, the impact of supply before the first quarter was negative, while that of office employment before the first quarter was positive. Also, that of interest rate before the second quarter was positive, while those of cap rate before the first quarter and cap rate before the second quarter were negative. Based on the findings, it is suggested that prediction models on Seoul offices need to be developed considering the influences of profitability, replacement cost, and demand on new office supplies in Seoul.

Design and Implementation of Wireless Device Management Agent based on OMA DM (OMA DM을 기반으로 한 무선이동통신 단말기 관리 에이전트 설계 및 구현)

  • Pak, Ju-Geon;Park, Kee-Hyun;Jang, Dae-Jin;Jang, Myung-Sook
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.4
    • /
    • pp.363-368
    • /
    • 2008
  • Mobile devices become more complex and harder to manage due to the advance of technologies. In this paper, we designed and implemented the DM Agent based on OMA(Open Mobile Alliance) DM(Device Management) which is a standard for mobile device management. The proposed DM Agent basically can manage parameter configuration through the commands ADD, DELETE, REPLACE and GET currently. Each module of the agent was designed and implemented separately for additional functions such as error reporting and software management. So the additional functions can be added by modifying Adaptor part which processes the management commands instead of modifying other modules which analyze or generate management commands. The DM Agent proposed in this paper is implemented based on WIPI(Wireless Internet Platform for Interoperability), therefore portability of the agent can be improved. In addition, this research can give a development example for dissenminating OMA DM as well as verify functional compatibility of WIPI platform. SK WIPI SDK and a Funambol DM test server are used to test operations of the implemented DM Agent.

Development of a Smartphone Application for Clinical Decision Making of Medication Administration (투약적용의 임상적 의사결정을 위한 스마트폰 어플리케이션의 개발)

  • Kim, Myoung-Soo;Park, Jung-Ha;Kim, Sungmin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1650-1662
    • /
    • 2014
  • This study aimed to develop smartphone application contents for the medication reconciliation of high-alert medications and to evaluate the satisfaction for this application. The xcode 4.5 and ios 6.1 SDK(software development kit) were used for constructing screen of the system. After implementation during 4 weeks, thirty five ICU(Intensive Care Unit) nurses were asked function related, contents related, and usage related satisfaction using 12 items. And differences of satisfaction according to the number of daily use and the frequency of use were evaluated. Data were analyzed using descriptive analysis, ANOVA with the SPSS 18.0. We developed the formula for drug dosage calculation, the alarming procedure, and the information of the high alert medication. In the satisfaction items, the mean score of 'This application is helpful to perform drug dosage calculation' was 3.14. However, 'I satisfy this application' was relatively low as 2.94. There were no differences in satisfaction according to the daily use and frequency of use. Based on the results of this study, more advanced smartphone application for medication reconciliation of high-alert medications will provide an important platform for patient safety.

An Electric Load Forecasting Scheme with High Time Resolution Based on Artificial Neural Network (인공 신경망 기반의 고시간 해상도를 갖는 전력수요 예측기법)

  • Park, Jinwoong;Moon, Jihoon;Hwang, Eenjun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.11
    • /
    • pp.527-536
    • /
    • 2017
  • With the recent development of smart grid industry, the necessity for efficient EMS(Energy Management System) has been increased. In particular, in order to reduce electric load and energy cost, sophisticated electric load forecasting and efficient smart grid operation strategy are required. In this paper, for more accurate electric load forecasting, we extend the data collected at demand time into high time resolution and construct an artificial neural network-based forecasting model appropriate for the high time resolution data. Furthermore, to improve the accuracy of electric load forecasting, time series data of sequence form are transformed into continuous data of two-dimensional space to solve that problem that machine learning methods cannot reflect the periodicity of time series data. In addition, to consider external factors such as temperature and humidity in accordance with the time resolution, we estimate their value at the time resolution using linear interpolation method. Finally, we apply the PCA(Principal Component Analysis) algorithm to the feature vector composed of external factors to remove data which have little correlation with the power data. Finally, we perform the evaluation of our model through 5-fold cross-validation. The results show that forecasting based on higher time resolution improve the accuracy and the best error rate of 3.71% was achieved at the 3-min resolution.

Surficial Sediment Classification using Backscattered Amplitude Imagery of Multibeam Echo Sounder(300 kHz) (다중빔 음향 탐사시스템(300 kHz)의 후방산란 자료를 이용한 해저면 퇴적상 분류에 관한 연구)

  • Park, Yo-Sup;Lee, Sin-Je;Seo, Won-Jin;Gong, Gee-Soo;Han, Hyuk-Soo;Park, Soo-Chul
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.747-761
    • /
    • 2008
  • In order to experiment the acoustic remote classification of seabed sediment, we achieved ground-truth data(i.e. video and grab samples, etc.) and developed post-processing for automatic classification procedure on the basis of 300 kHz MultiBeam Echo Sounder(MBES) backscattering data, which was acquired using KONGBERG Simrad EM3000 at Sock-Cho Port, East Sea of South Korea. Sonar signal and its classification performance were identified with geo-referenced video imagery with the aid of GIS (Geographic Information System). The depth range of research site was from 5 m to 22.7 m, and the backscattering amplitude showed from -36dB to -15dB. The mean grain sizes of sediment from equi-distanced sampling site(50 m interval) varied from 2.86$(\phi)$ to 0.88(\phi). To acquire the main feature for the seabed classification from backscattering amplitude of MBES, we evaluated the correlation factors between the backscattering amplitude and properties of sediment samples. The performance of seabed remote classification proposed was evaluated with comparing the correlation of human expert segmentation to automatic algorithm results. The cross-model perception error ratio on automatic classification algorithm shows 8.95% at rocky bottoms, and 2.06% at the area representing low mean grain size.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

Efficiently Development Plan from the User's Need Analysis of the Army Tactical C4I(ATCIS) System (지상전술 C4I(ATCIS)체계 운용자 요구분석을 통한 효율적 발전 방안)

  • Park, Chang-Woon;Yang, Hae-Sool
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.5
    • /
    • pp.246-259
    • /
    • 2008
  • This study was to minimize the trial and error in the primary step of the C4I system(ATCIS) of the each army corps on the front line, and test the economy and efficiency was tested by reviewing related papers and the system characteristics of other countries. The relationship was researched by analyzing the collected survey data and survey data related to the user's requirement level such as the army standards, that is, commonality, timeliness, simplification, automaticity, field availability and viability, multi-stage security and interoperability, unification. The result showed that the C4I system was efficiently operated through the system reliability for the specification of the system and operation manual, maneuverability and security, adaptability of the war field and system support and management, and good education and training about system operation, and less system maintenance and supplementary element. As a result, the development plan confirmed that the continuous operator education and the construction of the maintenance, and the upgrade digitalization(C4ISR+D) with the korean characteristics based on IT of network systems, and system development of the measurement model of the operator performance must be continuously supplemented in the near future.

Evaluation of Analyzer and Measurement Conditions of Blood Ammonia (혈중 암모니아의 측정조건과 분석기기의 평가)

  • Kim, Sang-Su;Kim, Myong Soo;Lee, Seung Mo;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.48 no.2
    • /
    • pp.68-73
    • /
    • 2016
  • Ammonia is very toxic, and causes neuronal damage via excitotoxicity, oxidative stress, and inflammation. Because the liver is the primary organ for ammonia metabolism, compromised liver function can result from inborn errors of metabolism. Measurement of blood ammonia has some limitations. Recently, several laboratories examined possible concurrent increases in plasma ammonia. However, the collection, handling, storage, and analysis of blood samples are all potential sources of error. For evaluation of rapidity and reliability of measurement of blood ammonia, the DRI-CHEM 100 (Fuji Film Co., Japan) and COBAS 8000 (Roche Diagnostic Ltd., Switzerland) analyzer were used for analysis of ammonia level values. The results of this study detected a high correlation between analyzer. Therefore, one-step measurement was suitable for ammonia analysis. After sampling of the ammonia in the time slot for measurement an increase to 46.5, 57.4, and 79.0 (${\mu}g/dL$) was observed at 30, 90, and 180 minutes. In addition, specific capacity of the ammonia, 7, 10, and 13 (${\mu}L$), was measured as 39, 46, and 43 (${\mu}g/dL$), respectively, and the FDC-100 analyzer was more effective in $10{\mu}L$ (p<0.001). In conclusion, the evaluated analysis may offer useful information for clinical application.

Experiment on Camera Platform Calibration of a Multi-Looking Camera System using single Non-Metric Camera (비측정용 카메라를 이용한 Multi-Looking 카메라의 플랫폼 캘리브레이션 실험 연구)

  • Lee, Chang-No;Lee, Byoung-Kil;Eo, Yang-Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.4
    • /
    • pp.351-357
    • /
    • 2008
  • An aerial multi-looking camera system equips itself with five separate cameras which enables acquiring one vertical image and four oblique images at the same time. This provides diverse information about the site compared to aerial photographs vertically. The geometric relationship of oblique cameras and a vertical camera can be modelled by 6 exterior orientation parameters. Once the relationship between the vertical camera and each oblique camera is determined, the exterior orientation parameters of the oblique images can be calculated by the exterior orientation parameters of the vertical image. In order to examine the exterior orientation of both a vertical camera and each oblique cameras in the multi-looking camera relatively, calibration targets were installed in a lab and 14 images were taken from three image stations by tilting and rotating a non-metric digital camera. The interior orientation parameters of the camera and the exterior orientation parameters of the images were estimated. The exterior orientation parameters of the oblique image with respect to the vertical image were calculated relatively by the exterior orientation parameters of the images and error propagation of the orientation angles and the position of the projection center was examined.

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.