• Title/Summary/Keyword: Influent and effluent

Search Result 364, Processing Time 0.023 seconds

Study on Concentrations and Mass Flows of Perfluorinated Compounds (PFCs) in a Wastewater Treatment Plant (폐수처리장의 과불화화합물 검출수준 및 처리공정 중 물질흐름 해석에 관한 연구)

  • Park, Jong-Eun;Kim, Seong-Kyu;Oh, Jung-Keun;Ahn, Sung-Yun;Lee, Mi-Na;Cho, Chon-Rae;Kim, Kyoung-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.326-334
    • /
    • 2012
  • To determine the concentrations and the mass flow of selected 10 perfluorinated compounds (PFCs), a field study was conducted in a wastewater treatment plant. Raw influent, primary influent, primary effluent, aeration tank effluent, secondary effluent, final effluent, dehydration liquor, primary sludge, thickened sludge, final sludge were collected over 3 days in the summer and the winter respectively. Collected samples were equally mixed and then served as an analytical sample. Total 10 compounds were analyzed. In terms of treated water, the concentration of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) were in range of N.D.~26.29 ng/L and N.D.~38.15 ng/L respectively. Perfluorononanoate (PFNA) and perfluorohexanesulfonate (PFHxS) were ranged from N.D. to 36.79 ng/L and from N.D. to 24.36 ng/L. In terms of sludges, a concentration of PFOS, PFOA, and perfluorodecanesulfonate (PFDS) were detected from 6.82 to 59.37 ng/g, from 0.13 to 0.37 ng/g, from N.D. to 0.83 ng/g respectively. Mass loading for PFCs increased during wastewater treatment except for PFNA. The observed increase in mass flow of PFCs may have resulted from biodegradation of precursor compounds.

Analysis of Optical Properties of Organic Carbon for Real-time Monitoring (유기탄소 실시간 모니터링을 위한 분광학적 특성인자 분석)

  • You, Youngmin;Park, Jongkwan;Lee, Byungjoon;Lee, Sungyun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.344-354
    • /
    • 2021
  • Optical methods such as UV and fluorescence spectrophotometers can be applied not only in the qualitative analysis of dissolved organic matter (DOM), but also in real-time quantitative DOM monitoring for wastewater and natural water. In this study, we measure the UV254 and fluorescence excitation emission spectra for a sewage treatment plant influent and effluent, and river water before and after sewage effluent flows into the river to examine the composition and origin of DOM. In addition, a correlation analysis between quantified DOM characteristics and dissolved organic carbon (DOC) was conducted. Based on the fluorescence excitation emission spectra analysis, it was confirmed that the protein-type tryptophan-like DOM was the dominant substance in the influent, and that the organic matter exhibited relatively more humic properties after biological treatment. However, DOM in river water showed the fluorescence characteristics of terrestrial humic-like and algal tyrosine-like (protein-like) organic matter. In addition, a correlation analysis was conducted between the DOC and optical indices such as UV254, the fluorescence intensity of protein-like and humic-like organic matter, then DOC prediction models were suggested for wastewater and river monitoring during non-rainfall and rainfall events. This study provides basic information that can improve the understanding of the contribution of DOC concentration by DOM components, and can be used for organic carbon concentration management in wastewater and natural water.

Application of Dynamic $\bar{x}$-R Control Chart for Advanced Phase Isolation Ditch (APID) Process (APID공정 내 공정진단을 위한 dynamic $\bar{x}$-R 관리도의 적용)

  • An, Sang-Woo;Kwak, Sung-Keun;Jung, Young-Wook;Chung, Mu-Keun;Park, Jae-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.704-712
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate and monitor the effluent water quality ($BOD_5$, SS, T-N, and T-P) and operating conditions (Influent, SVI, SRT, and HRT) as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 7.7, 5.6, 10.8, and 1.6 mg/L. Trend analysis of influent $BOD_5$, SS, T-N, and T-P in APID process were illustrated that APID process need for more strong APID process management on the winter session, such as developing new intermediated aeration mode, operating methods, and managements strategy. At the application of control chart, the signal of uncommon effects at APID process was determined much higher existing control chart tntr conventional control chart in this study. These results indicate that conventional control chart has been collected and determined cleary signal at only stable situation. Therefore, newly developed APID process of dynamic control chart can be one of the useful tool for monitoring and management process.

Quantitative Determination of PFOA and PFOS in the Effluent of Sewage Treatment Plants and in Han River (서울시 하수처리장 방류수 및 한강 내 PFOA와 PFOS의 과불화화합물 모니터링 연구)

  • Shin, Mi-Yeon;Im, Jong-Kwon;Kho, Young-Lim;Choi, Kyoung-Sik;Zoh, Kyung-Duk
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.4
    • /
    • pp.334-342
    • /
    • 2009
  • Perfluorinated compounds (PFCs) have a wide range of domestic and industrial applications, but they are persistent in the environment. Perfluorooctanoic acid (PFOA) and perfluorooctanesulfonate (PFOS) are among the metabolites of PFCs and occur at high concentration in the environment. Korea is the largest importer of PFC compounds in the world, therefore, the accumulation of these compounds is possible. In this study, the concentrations of PFOS and PFOA were determined in water samples taken from sewage treatment plants (STPs) and the Han River in Seoul, Korea. After extraction with a HLB cartridge, PFCs in the samples were analyzed by HPLC with an ion trap mass spectrometry in electrospray negative mode. Limits of detection was between 1 and 1.6 ng/l. The result showed that the concentrations of PFOS and PFOA in effluent and influent of the four STPs in Seoul were 60~570 ng/l, and not detected (nd)~254 ng/l, respectively. The levels of PFOS and PFOA were higher in the effluents which passed through the treatment process than in influent water samples which was against expectation. The concentration of PFOA and PFOS in the Han River was 60~570 ng/l and nd~254 ng/l, respectively. PFOA was detected in every sample, but PFOS was only detected in the downstreams of the Han River. This result indicates that there is comprehensive contamination of PFCs in the aquatic environment in Korea.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

Correlation analysis between TOC and organic matter indices in influent and effluent of public sewage treatment facilities (공공하수처리시설 유입수 및 방류수에서 TOC와 유기물질 관리지표간의 상관성 분석)

  • Son, Dong-Jin;Jeong, Dong-Hwan;Park, Kyoo-Hong
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • As the total organic carbon (TOC) becomes a new water quality standard as an organic matter (OM) index for public sewage treatment facilities (PSTFs) in Korea from 2021, a comparison study needs to be conducted by examining the correlation between TOC and the existing OM indices (DOC, BOD5, CODMn, CODCr). 500 PSTFs were categorized by process configuration and capacity, and correlation between OM indices in influent and effluent was analyzed. The CODMn/TOC showed higher correlation than other OM indices. This results can be used to basic data for various research associated with TOC.

Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank (총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구)

  • Kim, Jong-Oh;Jung, Dong-Gi;Kwon, Hye-Jeong;Hwang, Joon-Seok
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

Removal of Dissolved Heavy Metals in Abandoned Mine Drainage by Ozone Oxidation System (오존산화를 이용한 폐광산배수 내 용존 중금속 제거에 관한 연구)

  • Seo, Suk Ho;Ahn, Kwang Ho;Lee, Jung Kyu;Kim, Gun Jooung;Chu, Kyoung Hoon;Ra, Young Hyun;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.725-731
    • /
    • 2010
  • This study was to evaluate the ozone oxidation of dissolved Fe, Mn, $SO{_4}^{2-}$ ions and color in abandoned mining drainage by conducting a bench-scale operation at various reaction times in an ozone reactor. The influent was collected from an abandoned mine drainage (AMD) near the J Mine in Jungsungun, Kangwon Province. The ozone reactor was operated at ozone reaction times of 10, 20 and 30 min with ozone doses of 0.0 and $2.4g\;O_3/hr$. Samples from each effluent from subsequent sand filtration were regularly collected and analyzed for pH, Fe, Mn, Al, Cr, Hg, $SO{_4}^{2-}$, alkalinity, color, ORP, TDS and EC. The effluent concentrations of Fe and Mn from the sand filter were less than 0.1 mg/L, which were below the concentrations on Korean drinking water quality standards (Fe, Mn < 0.30 mg/L). The influent $SO{_4}^{2-}$, concentrations were not noticeably changed during this ozone oxidation. Cr and Hg in the raw wastewater from the abandoned mining drainage were not detected in this study. The experimental result shows that the ozone oxidation of dissolved heavy metals and subsequent sand filtration of metal precipitates are desirable alternative for removing heavy metals in AMD.

Methane production by high temperature anaerobic digestion of food wastes

  • Song, Hyo-Jeong;Seo, Jin-Ho;Kim, Seong-Jun
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.266-269
    • /
    • 2005
  • This study targeted methane production and decrease of organic materials concentration by high temperature anaerobic digestion of food waste. A anaerobic reactor with circulation was employed and the operation condition as follows: high temperature of $45{\pm}2,$ 0.6 $kg-VS/m^3/d,$ HRT of 70 days, pH of $6.8{\sim}7.2$. The CODcr removal rate of $75%{\sim}85%$ with effluent of $14,000{\sim}19,000$ mg/L in case of influent of $75,000{\sim}95,000$ mg/L showed. In influent TS(Total Solid) and VS(Volatile Solid) concentration of $2.94%{\sim}5.09%,$ and $2.98{\sim}5.01%,$ the effluent concentration was $0.65{\sim}1.1%$ and $0.6%{\sim}0.8%,$ respectively. 0.28 $m^3-CH_4$ / kg-VS was averagely obtained in the system.

  • PDF

Optimization of membrane fouling process for mustard tuber wastewater treatment in an anoxic-oxic biofilm-membrane bioreactor

  • Chai, Hongxiang;Li, Liang;Wei, Yinghua;Zhou, Jian;Kang, Wei;Shao, Zhiyu;He, Qiang
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.196-202
    • /
    • 2016
  • Membrane bioreactor (MBR) technology has previously been used by water industry to treat high salinity wastewater. In this study, an anoxic-oxic biofilm-membrane bioreactor (AOB-MBR) system has been developed to treat mustard tuber wastewater of 10% salinity (calculated as NaCl). To figure out the effects of operating conditions of the AOB-MBR on membrane fouling rate ($K_V$), response surface methodology was used to evaluate the interaction effect of the three key operational parameters, namely time interval for pump (t), aeration intensity ($U_{Gr}$) and transmembrane pressure (TMP). The optimal condition for lowest membrane fouling rate ($K_V$) was obtained: time interval was 4.0 min, aeration intensity was $14.6 m^3/(m^2{\cdot}h)$ and transmembrane pressure was 19.0 kPa. And under this condition, the treatment efficiency with different influent loads, i.e. 1.0, 1.9 and $3.3kgCODm^{-3}d^{-1}$ was researched. When the reactor influent load was less than $1.9kgCODm^{-3}d^{-1}$, the effluent could meet the third discharge standard of "Integrated Wastewater Discharge Standard". This study suggests that the model fitted by response surface methodology can predict accurately membrane fouling rate within the specified design space. And it is feasible to apply the AOB-MBR in the pickled mustard tuber factory, achieving satisfying effluent quality.