• Title/Summary/Keyword: Influent and effluent

Search Result 364, Processing Time 0.03 seconds

Occurrence of EDC/PPCPs in Influent and Effluent of a Wastewater Treatment Plant (하수처리장 유입.유출수 내 EDC/PPCPs의 발생 특성)

  • Lee, Min-Ju;Ryu, Jae-Na;Oh, Je-Ill;Kim, Hyun-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.783-792
    • /
    • 2009
  • This study investigated 31 selected EDCs(Endocrine Disrupting Compounds) and PPCPs(Pharmaceutical and Personal Care Products) in the influent and effluent of a wastewater treatment plant(WWTP) nearby Seoul metropolitan area. The chemical compounds of EDC/PPCPs detected from the plant influent sample include stimulant, X-ray contrast media and fire retardant. The total amount of each compound class were 59.67%, 20.20% and 9.00% respectively. However, in the effluent sample, the major micropolutants detected were oral beta-blocker(30.54%), fire retardant(20.49%), X-ray contrast media(18.17%). The EDC/PPCPs occurrence levels of this study were somewhat lower than previous domestic studies'. When compared to those of overseas, the values were even lower. Some pharmaceutical compound levels particularly measured in European studies were even several thousand times high. This study then compared PECs(Predicted Environmental Concentration) and MECs(Measured Environmental Concentration) of 9 selected pharmaceuticals compounds. The calculated PECs were substantially different with the MECs, while the occurrence order between the PECs and MECs in terms of concentrations of the compounds were similar.

Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준)

  • Yang, Hong-Mo;Rhee, Chong-Ouk
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • A model of pond system is developed for treatment and recycling of excreta from twenty-five adult dairy cattle. It is composed of wastewater treatment ponds and small fish ponds. Those are three facultative ponds in series; primary-secondary-tertiary pond and these are designed to rear carps without feeding. A pit is constructed at the bottom of primary pond for efficient sludge sedimentation and effective methane fermentation. It is contrived to block into it the penetration of oxygen dissolved in the upper layer of pond water. The excreta from the cattle housed in stalls are diluted by water used for clearing them. The washed excreta flow into the pit. The average yearly $BOD_5$ concentration of influent is 398.7mg/l. That of the effluent from primary, secondary and tertiary pond of the system is 49.18, 27.9, and 19.8.mg/l respectively. Approximate 88, 93, and 95 % of BOD5 are removed in each pond. The mean yearly SS concentration of influent is 360.5 mg/l That of the effluent from each pond is 53.4, 45.7, and32.7mg/l respectively. Approximate 86, 88, and 91% of SS are removed in each pond. The $BOD_5$ concentration of secondary and tertiary pond can satisfy 30mg/l secondary treatment standard. The SS concentration of effluent from tertiary pond, however, is slightly greater than the standard, which results from activities of carps growing in the pond. The average yearly total nitrogen concentration of influent is 206.8mg/l and that of the effluent from each pond is 48.6, 30.8, and 21.0mg/l respectively. Approximate 74, 88, and 90% of total nitrogen are removed in each pond. The mean yearly total phosphorous concentration of influent is 20.7mg/l and that of the effluent from each pond is 5.3, 3.2, and 2.1mg/l respectively. Approximate 97, 98, and 99% of total phosphorous are removed in each pond. The high removal of nitrogen and phosphorous results from active growth of algae in the upper layer of pond water. Important pond design parameters for southern part of Korea -- areal loading of BOD5, liquid depth, hydraulic detention time, free board, and pond arrangement -- are taken up.

  • PDF

Phenolic Wastewater Treatment by a Mixed Culture GE2 Immobilized on Activated Carbon

  • Oh, Hee-Mock;Ku, Young-Hwan;Ahn, Keuk-Hyon;Kwon, Gi-Seok;Kho, Yung-Hee;Mheen, Tae-Ick;Yoon, Byung-Dae
    • Journal of Microbiology and Biotechnology
    • /
    • v.6 no.2
    • /
    • pp.116-119
    • /
    • 1996
  • The biological treatment by a mixed culture GE2 immobilized on activated carbon was investigated with a phenolic resin industrial wastewater containing 41,000 mg/l of phenol and 2,800 mg/l of formaldehyde. At a dilution of 20 times with aerated tap water, influent and effluent $COD_{Mn}$ were 4,587 mg/l and 46 mg/l, that is, $COD_{Mn}$ removal efficiency was 99.0%. At this time, phenol and formaldehyde con-centration of the effluent were 1.24 and 6.80 mg/l, indicating removal efficiencies of 99.9 and 94.1%, respectively.

  • PDF

Influence of Pipe Materials and VBNC Cells on Culturable Bacteria in a Chlorinated Drinking Water Model System

  • Lee, Dong-Geun;Park, Seong-Joo;Kim, Sang-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1558-1562
    • /
    • 2007
  • To elucidate the influence of pipe materials on the VBNC (viable but nonculturable) state and bacterial numbers in drinking water, biofilm and effluent from stainless steel, galvanized iron, and polyvinyl chloride pipe wafers were analyzed. Although no HPC (heterotrophic plate count) was detected in the chlorinated influent of the model system, a DVC (direct viable count) still existed in the range between 3- and 4-log cells/ml. Significantly high numbers of HPC and DVC were found both in biofilm and in the effluent of the model system. The pipe material, exposure time, and the season were all relevant to the concentrations of VBNC and HPC bacteria detected. These findings indicate the importance of determining the number of VBNC cells and the type of pipe materials to estimate the HPC concentration in water distribution systems and thus the need of determining a DVC in evaluating disinfection efficiency.

Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System (DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구)

  • Lee, Byoung Ho;Kim, Sang Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

Treatment of Animal Wastewater with Absorbent Oxidation (축산폐수의 흡착산화 처리)

  • 오인환;박정현;이명규;전병태;김형화
    • Journal of Bio-Environment Control
    • /
    • v.3 no.2
    • /
    • pp.136-144
    • /
    • 1994
  • A long- time aeration method was developed for purification of animal wastewater. Under repeated aereations of 4 hours on and 4 hours off, the higher removal rates were obtained which were in average of 99%, 96%, 92% and 50% for BOD, SS, total nitrogen and phosporous, respectively. In detail, the measured BOD concentrations of the influent and effluent were 2,700ppm and 40ppm while the SS concentrations in the primary chamber and of the effluent were about 3,000 and 110 ppm, respectively. Zeolite and activated carbon, applied for removing the nitrogen and phosphorous, showed a good absorption, especially zeolite for NH$_4$-N and activated carbon for NO$_3$-N and PO$_4$-P. The treatment cost per head by this method amounts to 1,923 won and it comes to 1.6% in the whole production cost. Therefore, this method is economically available with the half cost of the conventional activated sludge process.

  • PDF

Artificial Neural Network Modeling and Prediction Based on Hydraulic Characteristics in a Full-scale Wastewater Treatment Plant (실규모 하수처리공정에서 동력학적 동특성에 기반한 인공지능 모델링 및 예측기법)

  • Kim, Min-Han;Yoo, Chang-Kyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.5
    • /
    • pp.555-561
    • /
    • 2009
  • The established mathematical modeling methods have limitation to know the hydraulic characteristics at the wastewater treatment plant which are complex and nonlinear systems. So, an artificial neural network (ANN) model based on hydraulic characteristics is applied for modeling wastewater quality of a full-scale wastewater treatment plant using DNR (Daewoo nutrient removal) process. ANN was trained using data which are influents (TSS, BOD, COD, TN, TP) and effluents (COD, TN, TP) components in a year, and predicted the effluent results based on the training. To raise the efficiency of prediction, inputs of ANN are added the influent and effluent information that are in yesterday and the day before yesterday. The results of training data tend to have high accuracy between real value and predicted value, but test data tend to have lower accuracy. However, the more hydraulic characteristics are considered, the results become more accuracy.

Evaluation on Environmental Bio-toxicity of Industrial Wastewater (산업폐수의 생물독성 발현에 관한 연구)

  • Kim, S.H.;Cheon, S.U.;Shin, K.S.;Jung, D.I.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.274-276
    • /
    • 2005
  • To investigate bioassay for toxic level evaluation of wastewater, toxic levels were checked influents and effluents of 6 wastewater discharge facilities with Daphnia magna and Vibrio fischeri. In view of test duration, D. magna is preferred at 48 hours. And it was judged to efficient that one of the two was choosen for toxicity test method (Daphnia test and Vibrio test). Analysis data for wastewater is average toxic level for influent more higher than effluent. And effluent toxic level is sharp decrease than effluents.

Verification of biological nitrogen removal model in anoxic-oxic process (무산소-산소 공정에서 생물학적 질소 제거 모델의 검증)

  • Lee Byung-Dae;Cheong Kung-Hoon
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1155-1161
    • /
    • 2005
  • Anoxic-oxic process were analyzed numerically for the each unit and final TN effluent by Water Quality Management(WQM) model and the results were compared data from these sewage or wastewater treatment plants. No bugs and logic error were occurred during simulation work. All of the simulation results tried to two times were obtained and both results were almost same thus this model has good reappearance. A few of simulation results were deviated with measured data because lack of influent water qualities are reported however simulation results have wholly good relationship with measured data. Also each unit of simulation result was kept good relationship with that of measured data therefore this WQM model has good reliance. Finally, WQM model predicts final TN effluent within ${\pm}4.1\;mg/{\ell}$

Nitrogen Removal from ADEPT Effluent of Piggery Wastewater using Nitritation/Denitiritation System (ADEPT공정을 거친 돈사폐수의 아질산화-아탈질 공정을 이용한 질소제거)

  • Lee, Hwa-Sun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.134-139
    • /
    • 2006
  • Partial nitirification and denitrification process has been reported to be technically feasible and economically favorable, especially for wastewater treatment with high ammonium concentration or low Carbon/Nitrogen ratio. This research was performed to survey nitrite accumulation by nitritation in treating ADEPT effluent of piggery wastewater, which contains highly concentrated ammonia. To estimate the possibility of nitrite accumulation, DO concentration and SRT were investigated as key operational parameters. This result proved that nitritation to nitrite was steadily obtained under short sludge retention time. Oxygen limitation was proved to be just a subsidiary parameter. Energy efficiency of nitritation-denitritation process was higher than complete nitrification-denitrification because external carbon requirement for denitritation could be saved. Though the influent contained significant nonbiodegradable organic substrate, total nitrogen removal efficiency was more than 51% in nitritation-denitritation system.