• Title/Summary/Keyword: Industrial wastewater treatment

Search Result 492, Processing Time 0.024 seconds

Automation Development in Water and Wastewater Systems

  • Olsson, Gustaf
    • Environmental Engineering Research
    • /
    • v.12 no.5
    • /
    • pp.197-200
    • /
    • 2007
  • Advanced control is getting increasingly demanded in water and wastewater treatment systems. Various case studies have shown significant savings in operating costs, including energy costs, and remarkably short payback times. It has been demonstrated that instrumentation, control and automation (ICA) may increase the capacity of biological nutrient removing wastewater treatment plants by 10-30% today. With further understanding and exploitation of the mechanisms involved in biological nutrient removal the improvements due to ICA may reach another 20-50% of the total system investments within the next 10-20 years. Disturbances are the reason for control of any system. In a wastewater treatment system they are mostly related to the load variations, but many disturbances are created also within the plant. In water supply systems some of the major disturbances are related the customer demand as well as to leakages or bursts in the pipelines or the distribution networks. Hardly any system operates in steady state but is more or less in a transient state all the time. Water and energy are closely related. The role of energy in water and wastewater operations is discussed. With increasing energy costs and the threatening climate changes this issue will grow in importance.

Developments and future potentials of anaerobic membrane bioreactors (AnMBRs)

  • Visvanathan, Chettiyappan;Abeynayaka, Amila
    • Membrane and Water Treatment
    • /
    • v.3 no.1
    • /
    • pp.1-23
    • /
    • 2012
  • The coupling of anaerobic biological process and membrane separation could provide excellent suspended solids removal and better biomass retention for wastewater treatment. This coupling improves the biological treatment process while allowing for the recovery of energy through biogas. This review gives a basic description of the anaerobic wastewater treatment process, summarizes the state of the art of anaerobic membrane bioreactors (AnMBRs), and describes the current research trends and needs for the development of AnMBRs. The research interest on AnMBR has grown over the conventional anaerobic processes such as upflow anaerobic sludge blanket (UASB). Studies on AnMBRs have developed different reactor configurations to enhance performances. The AnMBR performances have achieved comparable status to other high rate anaerobic reactors. AnMBR is highly suitable for application with thermophilic anaerobic process to enhance performances. Studies indicate that the applications of AnMBR are not only limited to the high strength industrial wastewater treatment, but also for the municipal wastewater treatment. In recent years, there is a significant progress in the membrane fouling studies, which is a major concern in AnMBR application.

A Study on the Water Pollutant Discharge Inventories for the Improvement of Industrial Wastewater Management System: Primary Steel Manufacturing Facility and Petroleum Refining Products Manufacturing Facility (산업폐수 관리체계 개선을 위한 수질오염물질 배출목록 구축에 대한 연구: 1차 철강 제조업과 석유정제품 제조업)

  • Ahn, Taeung;Kim, Dongmin;Son, Daehee;Kim, Jaehoon
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.453-467
    • /
    • 2020
  • This study aimed to inventory the water pollutant discharge of wastewater from two facilities, one primary steel manufacturing facility and one petroleum refinery, both of which are located in Korea, and to identify ways to improve the wastewater treatment process through field investigation. Probability evaluation was used to inventory the substances in polluted water. The samples collected in this study included original wastewater, on processing wastewater, and treated water. The general description of wastewater occurrence, major sources, and treatment facilities were also investigated to obtain an integrated database of the pollutants created by different industrial categories. Based on our analysis of raw wastewater and final effluent, the detected pollutants were confirmed by analyzing their presence in the raw or supplemental materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The compounds detected for each category were screened via investigation of their possible sources and confirmed as the final water pollutant inventories. Thirty kinds of water pollutants were emitted by the primary steel manufacturing facility (reference in case A), including 14 specified hazardous water pollutants. The petroleum refinery (reference in case B) emitted 36 water pollutants, including 16 specified hazardous water pollutants.

Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater (산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정)

  • Park, Se-Jin;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.570-575
    • /
    • 2018
  • The various of raw wastewater inflows to the industrial wastewater treatment plants everyday. This makes it difficult to operate the coagulation and flocculation efficiently as a pretreatment process for the industrial wastewater treatment. Additionally, it causes loads on evaporation and membrane facilities which are the posttreatment and alternative processes. For this reason, this study sampled raw wastewater before and after the NaOH injection. An experiment was conducted to compare the coagulation characteristics according to the methods of coagulant injection (single injection, simultaneous injection, consecutive injection, and inverse injection) aiming at efficient treatment of industrial wastewater. The coagulation experiment was conducted using a jar tester. The TDS removal efficiency by the coagulant injection methods increased in the order of consecutive injection (2.8 %) < single injection (3.9 %) < simultaneous injection(8.1 %) < inverse injection(9.6 %); the TOC removal efficiency grew in the order of single injection (84.3 %) < inverse injection (86.2 %) < consecutive injection (88.6 %) < simultaneous injection (89.1 %); the turbidity removal efficiency grew from single injection (99.7 %) < consecutive injection (99.8 %) ${\fallingdotseq}$ inverse injection (99.8 %) < simultaneous injection (99.9 %). These results show that the simultaneous inorganic coagulant-polymer coagulant injection method was more efficient than the consecutive injection method (inorganic coagulant ${\rightarrow}$ polymer coagulant).

Effect of Coagulation, Ozone and UV Post-Process on COD and Color Removal of Textile Wastewater (응집, 오존 및 UV후처리가 염색폐수의 COD와 색도 제거에 미치는 영향)

  • 박영식;안갑환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.93-98
    • /
    • 2001
  • Wastewaters produced in textile industrial processes contain dyes which are not easily amenable to biological treatment. The object of this study is to determine the post-treatment system of biological process for the textile wastewater by comparing three different types of chemical process, which were 1) post-treatment by ozone or UV, 2) post-treatment by coagulation,3) post-treatment by ozone or UV followed by coagulation. In an application ozone or UV as a post-treatment, color was generally decreased with time, however, SCOD removal effect was not that good. When coagulation was used as point-treatment process, the effluent quality was satisfying. Therefore, the application of coagulation process as a post-treatment of biological process would be more desirable than that as a ozone or UV.

  • PDF

Isolation of Microorganisms and Development of Microbial Augmentation for Treatment of Industrial Wastewater containing Ammonium Nitrogen (암모니아성 질소함유 산업폐수처리를 위한 미생물의 분리 및 복합미생물제제의 개발)

  • Lee, Myoung-Eun;Mun, Seo-Jin;Kwon, Do-Hyuck;Suh, Hyun-Hyo
    • Journal of Life Science
    • /
    • v.30 no.2
    • /
    • pp.129-136
    • /
    • 2020
  • For effective treatment of wastewater containing ammonium nitrogen (NH4-N), AT2, AT9, and AT12 strains, having high total organic carbon (TOC) removal capability, and FN47, possessing excellent ammonia nitrogen removal capability present in the activated sludge in the aeration tank of food wastewater treatment plants, were isolated and identified. The cells of these isolated strains were used for microbial augmentation with FIW-1 in the defatted rice bran as a medium to treat industrial wastewater. The investigation of the cultural characteristics of these isolated strains in the aeration tank showed that the affinities for substrate of the isolated strains were extremely high, of which AT12 (Alcaligenes sp. AT12) was the highest among the isolated strains. Ammonium nitrogen removal efficiency in the food wastewater was 71% in the isolated strain FN47 (Microbacterium sp. FN47) treatment group. When only activated sludge was added in the lab scale pilot using food wastewater during continuous culture experiment, the TOC removal efficiency was 63%. Meanwhile, the removal efficiency of 92% was obtained when the microbial augmentation FIW-1 for wastewater treatment was applied. In addition, the chemical oxygen demand (COD) level from the effluent wherein microbial augmentation FIW-1 was input for the initial three days in the wastewater treatment site experiment showed a treatment rate of about 43%, which was increased to 62% after an elapse of 5 days.

Efects of Chitosan on Cell Flocculation in Soybean Curd Wastewater Treated by Photosynthetic Bacteria (Chitosan에 의한 광합성세균 처리 두부공업폐수의 균체 응집효과)

  • 오준현;조홍연;양한철
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.6
    • /
    • pp.763-769
    • /
    • 1995
  • As a mean to recover photosynthetic bacterial(PSB) cells and its practical uses in food industrial wastewater treatment, various biodegradable polyelectrolytes were first investigated for flocculation of suspended colloids in the PSB treatment process of soybean curd wastewater. Anionic polyelectrolytes such as sodium alginate and carrageenan were not effective but a cationic polyelectrolyte chitosan isolated from Portunus trituberclatus showed very effective flocculation activity. The concentration of chitosan, pH and temperature of wastewater for maximal flocculation were 40 mg/l, pH 7 and room temperature, respectively. Test using deacetylated chitosan to various degree showed higher flocculating activities in samples deacetylated over 75% and time for maximum flocculation was 40 min by stirring slowly under the above optimal conditions. Chitosan was not only effective to flocculate cells but also removed COD and MLSS of the wastewater. COD of 42% and MLSS of 87% were removed by addition of chitosan to the soybean curd wastewater treated with PSB.

  • PDF

Biological Treatability of Toxic Industrial Wastewater (독성산업폐수의 생물학적 처리)

  • 원성연;박승국;정근욱
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.172-179
    • /
    • 1999
  • In this research, biological treatability test was conduced using seawater flocculated tannery wastewater by fixed biofilm reactor. During one cycle, the removal efficiency of organic corbon obtained with fixed biofilm process for treating tannery wastewater was considerably greater than that with activated sludge process. As the hydraulic retention time increased form 0.5day to 4day, removal efficiency of organic carbon was increased from 72% to 87.3%. Attached biomass in media increased with influent organic loading up to 29g MLSS/L, that could reduce the specific organic loading rate. The continual measurement of attached biomass was possible for the operation of the biofilm reactor. Equal and low nitrication rates were observed in both suspended growth activated sludge process and fixed biofilm process, despite commercial nitrifier was seeded. Through the process of treating the tannery wastewater, EC50 values which is measured by the use of Ceriopdaphnia dubia, were decreased to the extent of 50% after treatment of seawater flocculation and of 83% after biological treatment, respectively, compared to those of the untreated wastewater.

  • PDF

Study on bio-gas production efficiency from industrial organic waste (산업계 유기성폐기물 바이오가스 생산 효율에 관한 연구)

  • Lee, Horyeong;Jin, Hyoeon;Shin, Daeyewn
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.629-636
    • /
    • 2012
  • This study focuses on the feasibility of bio-gas production using anaerobic digestion by measuring methane generation and biodegradability through the BMP test of industrial organic wastes. Organic wastes consist of entrails of pigs and organic residues of rumen generated from slaughter houses, wastewater sludge from slaughter waste water, fish offal and residues of vegetables from public wholesale markets, and wastewater sludge from the process of wastewater treatment in paper mill. The cumulative methane production by BMP test ranges from 149.3 ml/g-VS to 406.6 ml/g-VS and this is similar to methane generation of the normal wastewater sludge and food waste. As a result of measurement of biodegradability, wastewater sludge (S1 ~ S4) is low, ranging from 27.1% to 58.9 % and organic residues of rumen (G1) is low at 49.6 %. In conclusion, it turned out that raising the hydrolysis by various pre-treatments is necessary in order to produce bio-gas by using industrial organic wastes.