• Title/Summary/Keyword: Industrial site

Search Result 1,789, Processing Time 0.031 seconds

Site-Plan Types of Common Design's Goon Office Buildings and their Addition & Remodeling in Japanese Colonial Period (일제강점기 '공통형' 군청사의 배치 유형과 유형별 증·개축 경향)

  • Kim, Myungsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7629-7634
    • /
    • 2015
  • The purpose of this study is is to organize the site-plan types of common design's Goon office buildings in Japanese colonial period based on the main building's shape and main & attached building connection way and to investigate all the types' addition & remodeling ways. The study used literature research method, analysing the digital images, the annotation of the images, official documents between the Japanese government-general of Korea and To, and articles of newspapers or journals. The site-plans are sorted 5 types and subdivided 13 as their addition & remodelling ways. The initial shapes of site-plan were changed to apply every Goon's site circumstances, The main buildings were always in the center ahead and attached buildings behind or next to them in any cases of new construction, addition or remodeling. The buildings of the common design's were constructed until early 1930s and it means that their architectural level was lower than Pu office buildings, although both had same administrational level.

Development of Source Profiles and Estimation of Source Contribution for VOCs by the Chemical Mass Balance Model in the Yeosu Petrochemical Industrial Complex (여수석유화학산단 내 VOCs에 대한 오염원 분류표의 개발 및 CMB 모델에 의한 기여도 산정)

  • Jeon Jun-Min;Hur Dong;Kim Dong-Sul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.83-96
    • /
    • 2005
  • The purposes of this study were to characterize the local levels of VOCs (volatile organic compounds), to develop source profiles of VOCs, and to quantify the source contribution of VOCs using the CMB (chemical mass balance) model. The concentration of VOCs had been measured every 6-day duration in the SRO monitoring site in the Yeosu Petrochemical Industrial Complex from September 2000 to August 2002. The total of 35 target VOCs, which were included in the TO-14 designated from the U.S. EPA, was selected to be monitored in the study area. During a 24-h period, the ambient VOCs were sampled by using canisters placing about 10 ~ 15 m above the ground level. The collected canisters were then analyzed by a GC-MS in the laboratory. Aside from ambient sampling at the SRO site, the VOCs had been intensively and massively measured from 8 direct sources and 4 general sources in the study area. The results obtained in the study were as follows; first, the annual mean concentrations of the target VOCs were widely distributed regardless of monitoring sites in the Yeosu Petrochemical Industrial Complex. In particular, the concentrations of BTX (Benzene, Toluene, Xylene), vinyl chloride were higher than other target compounds. Second, based on these source sample data, source profiles for VOCs were developed to apply a receptor model, the CMB model. Third, the results of source apportionment study for the VOCs in the SRO Site were as follows; The source of petrochemical plant was apportioned by 31.3% in terms of VOCs mass. The site was also affected by 16.7% from wastewater treatment plant, 14.0% from iron mills, 8.4% from refineries, 4.4% from oil storage, 3.8% from automobiles, 2.3% from fertilizer, 2.3% from painting, 2.2% from waste incinerator, 0.6% from graphic art, and 0.4% from gasoline vapor sources.

A Study on Improvement of Process Safety Management System in Threshold Quantity Site (규정수량사업장의 공정안전관리제도 개선)

  • Jung, Jong-Soo;Kim, Yeon-Hee;Kim, Dong-Jin;Yi, Yun-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1289-1299
    • /
    • 2007
  • As higher on the industrialization of chemical factories in Korea, it shows a tendency that safety accident happens more times and is bigger on its size. For preventing from and decreasing such accident, PSM(Process Safety Management) system has used in chemical factories. Though it is recognized that PSM is sutable and effective for only a intensive system technically, it could be difficult to apply to all of factories, actually. This study was proceeded for investigating the effect and problems on the application and performanance of PSM into the threshold quantity site and suggesting how fur improvement. The results are as followed; PSM system was not used effectively in the threshold quantity site of medium and small-sized enterprises because of the shortage of experts and the decrease of interest as a deregulation. As the effective performanace of PSM for preventing from industrial accident in threshold quantity site and for sattling as self-system easily, it was concluded to get an active support from the concerned government. First of all, new progrems to improve PSM should be developed continually and the progrems should be educated extensively.

  • PDF

Development of Site Selection Planning Factors for Urban High-tech Industrial Complex: Focused on Old Industrial Complex Regeneration (도시첨단산업단지 입지선정을 위한 계획요소 도출: 노후산업단지 재생을 중심으로)

  • Park, Kwag-Jin;Lee, Myeong-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.5
    • /
    • pp.595-608
    • /
    • 2020
  • In order to derive site selection planning factors in reforming aging industrial complex into urban high-tech industrial complex, this study selected key planning factors based on the problems of creating the urban high-tech industrial complex, innovation system theory, and external effect theory. And combined with Delphi research, the final planning factors were selected. As a result of the study, total 19 final factors were derived from 4 areas which includes efficiency planning factor utilizing the advantages of old industrial complex regeneration to maximize the efficiency of the project, corporate demand factor via increasing pre-sale rate and strengthening competitiveness, human resource planning factor by maintaining work force of the tenant to utilize and promote accumulated knowledge, and cooperative relationship building factor by enhancing connectivity with neighboring areas. These planning factors will help revitalizing the local economy through the resolution of regional conflicts caused by low distribution rates and development imbalances, which have emerged as problems in the creation of urban high-tech industrial complexes.

Analysis of Organic Molecular Markers in Atmospheric Fine Particulate Matter: Understanding the Impact of "Unknown" Point Sources on Chemical Mass Balance Models

  • Bae, Min-Suk;Schauer, James J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.3
    • /
    • pp.219-236
    • /
    • 2009
  • Particle-phase organic tracers (molecular markers) have been shown to be an effective method to assess and quantify the impact of sources of carbonaceous aerosols. These molecular markers have been used in chemical mass balance (CMB) models to apportion primary sources of organic aerosols in regions where the major organic aerosol source categories have been identified. As in the case of all CMB models, all important sources of the tracer compounds must be included in a Molecular Marker CMB (MM-CMB) model or the MMCMB model can be subject to biases. To this end, the application of the MM-CMB models to locations where reasonably accurate emissions inventory of organic aerosols are not available, should be performed with extreme caution. Of great concern is the potential presence of industrial point sources that emit carbonaceous aerosols and have not been well characterized or inventoried. The current study demonstrates that emissions from industrial point sources in the St. Louis, Missouri area can greatly bias molecular marker CMB models if their emissions are not correctly addressed. At a sampling site in the greater St. Louis Area, carbonaceous aerosols from industrial point sources were found to be important source of carbonaceous aerosols during specific time periods in addition to common urban sources (i.e. mobile sources, wood burning, and road dust). Since source profiles for these industrial sources have not been properly characterized, method to identify time periods when point sources are impacting a sampling site, needs to avoid obtaining biases source apportionment results. The use of real time air pollution measurements, along with molecular marker measurements, as a screening tool to identify when point sources are impacting a receptor site is presented.

Determination of N,N-Dimethylformamide in Ambient Air Using Adsorption Sampling and Thermal Desorption with GC/MS Analysis (흡착-열탈착-GC/MS를 이용한 환경대기 중 N,N-Dimethylformamide 농도 측정)

  • Seo, Young-Kyo;Hwang, Yoon-Jung;Lee, Soon-Jin;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.4
    • /
    • pp.357-366
    • /
    • 2010
  • The purpose of this study is to evaluate a method for the measurement of N,N-Dimethylformamide (DMF) and to apply the method to the ambient air samples. For the determination of DMF together with other general VOCs (e.g., benzene, toluene, and xylenes), adsorption sampling and thermal desorption with GC/MS was used in this study. The sampling and analytical approaches tested in this study showed a good repeatability and linearity with lower detection limits of less than 0.35 ppb. Field measurements were carried out at three industrial sites (Daegu-Seongseo, Siwha and Banwall industrial complexes) and one residential site in Daegu city during a period from October 2006 to November 2008. DMF was detected in 71.8% of the total samples from the Seongseo industrial complex, well known for textile industry. In contrast, DMF was detected in only 20.4% and 12.9% of all the samples from the other two sites in Banwall and Siwha industrial complexes, respectively. This implies that sources of DMF should be strongly associated with textile industry. The mean concentration of DMF also appeared to be the highest in Seongseo site (5.95 ppb), followed by a residential site in Daegu (3.28 ppb), Banwall (0.88 ppb) and Siwha (0.55 ppb). In this study, we demonstrated the environmental significance of DMF in urban ambient air. To our knowledge, the DMF measurement introduced in this paper is the first case of an official report in Korea.

Residential Exposure and Risk Levels to Ambient Formaldehyde and Acetaldehyde According to Distance from Industrial Area in Metropolitan City

  • Jo, Wan-Kuen;Lee, Jin-Woo
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.671-680
    • /
    • 2010
  • The present study evaluated residential exposure to atmospheric formaldehyde and acetaldehyde according to distance from the a dyeing industry complex (DIC). This purpose was achieved by measuring concurrently the outdoor air concentrations in residences near the DIC and a certain distance away, plus the outdoor air concentrations at two industrial areas within the DIC boundary. Formaldehyde concentrations (median values of 24.3 and $22.5{mu}g/m^3$ in IS1 and IS2, respectively) were higher than acetaldehyde concentrations (median values of 7.4 and $7.3{mu}g/m^3$ in IS1 and IS2, respectively) at both sites. However, there was no significant difference in the industrial outdoor air concentrations of both formaldehyde and acetaldehyde between the two sites. In addition, the median formaldehyde concentration from the residential site near the DIC (RS1) was about 1.5 times higher than that from the residential site far away from the DIC(RS2), and the median acetaldehyde concentration from RS1 was about 1.3 times higher than that from RS2. It is noteworthy that the mean or median risk as well as these maximum risks are well above the USEPA's permissible risk level of $10^{-6}$ from environmental exposure. This suggests that appropriate management for formaldehyde and acetaldehyde is necessary in order to decrease risk of the residents of study areas, regardless of the distance from the DIC.

Measurement of Complex Odor from Industries and Regulated Odorous Substance in Public Complaint Areas of Changwon Industrial Complex, and Its Reduction Countermeasure (창원공단 주요 악취 민원 발생지역 주변 악취발생 현황조사 및 저감방안에 관한 연구)

  • Oh, Il-Hwan;Seo, Jeoung-Yoon;Kim, Tae-Hyung
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.525-535
    • /
    • 2008
  • 5 public complaint areas against odor in Changwon Industrial Complex were selected and investigated to clear up the cause of the complaint. 16 companies operated in public complaint areas were visited and had a grip of their situation about odor generation and treatment. Two samples at it's site boundary of each company were taken to measure complex odor unit. Complex odor unit at the site boundary of investigated companies in the public complaint areas, for the most part, exceeded standard(odor unit 20) in industrial area. It was due to that this area was not designated as odor control region and that there are also many problems in current laws of Odor Protection Act, Air Quality Act and regional legislation. Accordingly, It will be necessary to revise the related legislation, to organize governance, to financially support the improvement of environmental facilities and to enforce guidance and the regulation rigidly for the odor emission reduction in Changwon Industrial Complex.