• Title/Summary/Keyword: Industrial radiography

Search Result 61, Processing Time 0.025 seconds

Medical Preparedness in Radiation Accidents (방사선 사고시의 의료대책)

  • Kim, Eun-Sil;Kim, Jong-Soon
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.201-215
    • /
    • 1996
  • Radiation and radioactive materials serve man in many beneficial ways. Diagnostic X-ray, radiation therapy, and other nuclear medicine uses of radioactivity save thousands of lives each year. Industrial application of radiation, such as radiography, make many manufactured products more reliable and less expensive. Nuclear power plants are producing more electrical power each year and reducing our dependence on imported oil. However, radiation can and dose produce harmful effects particularly as the reault of a radiation accident in which a victim receives as the result of a radiation accident in which a victim receives a large dose. Fortunately such accidents are very rare and recently we need more electric power produced by nuclear power plants. Considering increase of use of radiation or radioactive materials, we have to establish the radiological emergency response system prepared for radiation accidents.

  • PDF

방사선투과사진에 의한 결함깊이 및 높이의 평가

  • 심언덕;이진우;이수경;강계명
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.249-256
    • /
    • 2002
  • 구조물의 안전성 평가와 수명예측은 구조물 내 결함에 관한 정확한 정보 즉, 결함의 종류, 크기, 위치, 형상으로 평가하고 있다 이들 결함의 분석과 해석 방법으로 실시간 평가가 가능하고, 구조물에 손상을 주지 않는 비파괴 결함 평가 방법이 널리 활용되고 있다. 특히 방사선투과시험에 의한 결함 해석과 평가는 투과사진 상에 나타나는 결함의 상으로부터 결함 형상과 결함 길이는 직접 확인할 수 있으며, 결함 깊이와 결함 높이의 해석에는 입체방사선투과검사법(Stereo-radiography)과 parallax법 등으로 현재 결함 깊이와 높이를 해석하고 있으나, 이러한 방법은 결함 검출을 위하여 조사방향을 여러방향으로 하여 방사선 투과사진을 다수 촬영하여야 하고, 촬영된 결함의 분석과 해석에도 숙련된 평가 기법이 요구되는 등 많은 문제점을 내포하고 있다.(중략)

  • PDF

Real Time Imaging of Solidification Behavior by Synchrotron X-ray Radiography (싱크로트론 X-선 투과영상법을 활용한 응고거동 실시간 관찰)

  • Lee, Sang-Mok;Yasuda, Hideyuki
    • Journal of Korea Foundry Society
    • /
    • v.30 no.1
    • /
    • pp.5-13
    • /
    • 2010
  • This article aims to introduce the synchrotron radiation for its utilization in the casting and solidification fields as an unique tool for observation of real time phenomena of molten metal during solidification. General features of the synchrotron radiation were briefly introduced for readers in the casting and solidification fields, with no background regarding to synchrotron radiation. And basic principles of imaging technologies using synchrotron light for in-situ observation of molten metal were explained together with exemplary research works, which were reported on the casting and solidification fields in recent years. As a practical guide, real time observation of Al-Si casting alloy was introduced with experimental facilities, image acquisition, and processing together with representative results.

Education and Training Program using HANARO

  • Seo, Kyung-Won;Han, Eun-Young
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.231-233
    • /
    • 1999
  • This report will introduce the epitome about the subject, HANARO (Hi-flux Advanced Neutron Application Reactor designed by KAERI in early 1995) Utilization Education Training Program Development and Operation, which is one of the nuclear research basic expansion businesses executed from 1999. 12. to strengthen the usage of HANARO. This program consists of the basic reactor experiments program for university students who have specialty of nuclear and other engineering, and the special research education program for faculties from universities and researchers from industrial fields. Principle lessons are reactor operation, radioisotope production, neutron activation analysis, neutron radiography, radiation shield (health physics), nuclear fuel combustion measurement by gamma scanning arrangement, and CNS (Compact Nuclear Simulator) and so on.

  • PDF

A case of pulmonic stenosis in a Shihtzu dog

  • Park, Chul;Yoo, Jong-Hyun;Jung, Dong-In;Kim, Ju-Won;Kang, Byeong-Teck;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.1
    • /
    • pp.99-102
    • /
    • 2007
  • A 3-year-old, intact female, Shih-tzu dog was presented with a 15-day history of vomiting,depression, and anorexia. On physical examination, systolic ejection murmurs with precordial thril atthe left heart base were detected. A diagnosis of congenital pulmonic stenosis (PS) was made mainlyfrom the thoracic radiography, electrocardiography, and echocardiography. On complete blood counts andconfirmed that main pulmonary artery was tremendously buldged and electrocardiography was suggestiveof severe right ventricular hypertrophy. Echocardiographic findings revealed the pulmonic valve stenosiscontaining valvular dysplasia and poststenotic dilation. On Doppler echocardiography, ejection velocityof the lesion accounted for 3.38 m/sec, meaning mild velocity through the stenotic area. The dog'sproblem and resulted in death. However, there has been no reliable relation between PS and CRF. Primarymalformation of pulmonic valve was confirmed at necropsy after death.

- A Study on Safety of the Radiation Exposure Dose Optimization at Chest B-ray Examinations - (사업장 단체검진 시 흉부촬영의 방사선피폭 최적화 및 안전에 대한 고찰)

  • Rhim Jae Dong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.3
    • /
    • pp.87-97
    • /
    • 2004
  • The National Health Insurance Act, the Industrial Health Act and the School Health Act require chest radiography at least once a year. In chest radiographic examination, most group examinations use indirect X-ray primarily aiming at diagnosing diseases and enhancing people's health. This study purposed to minimize radiation exposure dose by comparing it between direct and indirect chest X-ray studies. According to the result of comparing and analyzing radiation exposure dose, the average incident dose and penetrating dose were 0.929μGy and 0.179μGy respectively in direct chest X-ray and 6.807μGy and 1.337μGy in indirect chest X-ray In order to minimize radiation exposure dose at direct and indirect chest X-ray, indirect X-ray should be excluded from group examination if possible. Moreover, it is necessary to control the quality of equipment (Q/A & Q/C) systematically and to avoid using unqualified equipment in order to reduce radiation exposure dose.

Malignant Anal Sac Melanoma in a Dog

  • Ahn, Soo-Min;Cho, Kyoung-Oh;Kim, Sang-Ki;Jung, Dong-In;Yu, DoHyeon
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.349-352
    • /
    • 2019
  • A five-year-old female Yorkshire Terrier dog presented with a perianal mass. Fine needle aspiration revealed that the mass comprised two different types of cells: hepatoid epithelial cells and melanin-containing melanocytes. Histopathological examination confirmed perianal gland adenoma with malignant melanoma. Evidence of metastasis was found on thoracic radiography with soft-tissue densities observed within the pulmonary parenchyma. The dog survived for three months after diagnosis of malignant melanoma. This report describes the clinical findings, diagnostics used, cytological and histopathological findings, and the potential prognosis for a dog diagnosed with malignant anal sac melanoma.

A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography (Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구)

  • Lee, Sung-Sik;Lee, Jeong-Ki;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.356-362
    • /
    • 1999
  • Based on the assumption that film density increases exponentially with exposure in the industrial radiographic film. an equation representing the characteristic curves of industrial radiographic films and a new density-thickness relation are suggested. The accuracy and reliability of the suggested relation has been tested using radiographs of a carbon steel step wedge with known thickness variation by polychromatic X-ray and ${\gamma}$-ray ($Ir^{192}$). The experimental results were well agreed to the proposed relation in the range of film densities from 1.0 to 3.5 and it was more accurate than the conventional relation. It is also found that ${\gamma}$-ray is more effective in this purpose than polychromatic X-ray, which results in variation of effective linear absorption coefficient due to beam hardening effect as thickness increases. Therefore using the equation and experimentally determined parameters the quantitative evaluation of thickness variation is possible and it can be used to evaluate the depth of local corrosion of pressure vessels in plants.

  • PDF

Factors affecting radiation safety management of dental hygienist and anxiety of radiation exposure (치과위생사의 방사선 안전관리 실태 및 피폭 불안감에 영향을 미치는 요인)

  • Lee, Hye-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.432-439
    • /
    • 2018
  • The purpose of this study was to analyze the knowledge, attitudes, safety management behavior, and radiation anxiety of dental hygienists and to analyze affecting factors in order to improve the level of radiation safety management and reduce anxiety. The study period consisted of 280 dental hygienists working in Jeollabuk-do from September 10 to October 31, 2017 using the SPSS 12.0 program, frequency, descriptive statistics, and multiple regression analysis. The average knowledge level of radiation quality control was 8.07, and the correct answer rate was 75.3%. The attitude level was 96.1%, and the radiation safety management behavior was 4.11 for the photographer and 4.58 for the 'always wear a TLD (personal dosimeter) during radiography'. Patient radiation safety management behavior was 3.86, and the highest was '4.69' to confirm pregnancy of the woman before radiography. Radiation-covered lining was 3.86, and was the highest at 4.13 for 'I am concerned about fetal health when I am pregnant'. Factors affecting radiation exposure anxiety were lower radiation safety management behaviors, lower age, lower radiographic experience, higher educational background, higher monthly income, and higher job title (p<0.05). Based on the above results, dental hygienists had strong knowledge, attitudes, and safety management practices for radiation quality control. However, since anxiety related to radiation exposure was high, it is possible to improve radiation safety management level and reduce radiation exposure anxiety.

The Effects of a Thyroid Shield Made of a Tissue-Equivalent Material on the Reduction of the Thyroid Exposure Dose in Panoramic Radiography (파노라마촬영 시 조직등가물질을 이용한 갑상선보호대의 갑상선피폭선량 감소효과)

  • Lee, Hye-Lim;Kim, Hyun-Yung;Choi, Hyung-Wook;Lee, Hye-Mi;Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2278-2284
    • /
    • 2012
  • Exposure-dose reducing effect was measured by using bolus, a tissue-equivalent material as a shield to obtain useful diagnostic images while minimizing the radiation exposure of thyroid which is highly sensitive to radiation during panoramic radiography. The experiment was performed within the period of 1 June 2001 through 30 June 2011 by measuring entrance surface dose and deep dose at the thyroid-corresponding site of a head and neck phantom. As a result, the entrance surface dose in the thyroid for using no shield was 43.84 ${\mu}Gy$ on the average, and the thyroid shield of bolus 10 mm in thickness reduced the dose by 15.45 ${\mu}Gy$(35.24%) to 28.39 ${\mu}Gy$ on the average. The use of a 20 mm thyroid shield resulted in the dose of 25.38 ${\mu}Gy$ on the average, a 18.46 ${\mu}Gy$(42.10%) drop from 43.84 ${\mu}Gy$ for using no shield. On the site 20 mm below the surface, a thyroid shield 10 mm in thickness had no dose-reducing effect, while a 20 mm thyroid shield reduced the dose by 0.06 mSv(20%).