• Title/Summary/Keyword: Industrial point source

Search Result 169, Processing Time 0.021 seconds

The Runoff Characteristics of Non-point Pollution Sources in Industrial Complex(I): Focusing on the analysis of runoff water according to the initial rainfall of the C Industrial Complex (산업단지 비점오염원의 유출특성(I): C산업단지의 초기강우에 따른 유출수 분석을 중심으로)

  • Woo, Jae-Suk;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.1
    • /
    • pp.23-32
    • /
    • 2022
  • In this study, rainfall water outlet water quality monitoring was performed on the C industrial complex to evaluate the characteristics of non-point pollutant runoff from the industrial complex during rainfall and to use it as basic data for calculating the load and unit of non-point pollutant. As a result of the IETD analysis, it was selected as a representative rainfall event for simulating non-point pollutants when the rainfall duration was about 21 hours and the rainfall was 26.44mm. Also as a result of monitoring the flow and water quality survey, the first rainfall was 12.2 mm, the rainfall duration was 12 hr, the number of preceding dry days was 3 days, the second rainfall was 22.1 mm, the rainfall duration was 12 hr, and the number of preceding dry days was 7 days.

Unambiguous Identification of Fugitive Pollutants and Determination of Annual Emission Flux as Diurnal Monitoring Mode

  • Chang, Shih-Yi;Tso, Tai-Ly;Lo, Jiunn-Gung;Huang, Jer-Luen;Lin, Cheng Ming
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.731-738
    • /
    • 1995
  • Toxic air pollutants are investigated in a petrochemical industrial park in Taiwan by using a movable open path FTIR. The results show the qualitative and quantitative analysis of emission gases from plants, and also provide the emission rate of different compounds. More than twenty compounds under usual operation are found from this industrial park. The concentration variation with time can be correlated exactly with wind direction. It means that by changing the measuring points, the source of emission can be unambiguously identified. An EPA proved PAL model is applied to estimate the emission rate of either a point or an area source. Local atmospheric stability is determined by releasing the $SF_6$ tracer. The origins of errors come mainly from the uncertainty of source's configuration and the variation of meteorological condition. Through the continuous measurement (half an hour base in this study) of OP-FTIR sensor, the maximum value of emission rate and the annual amount of emission can be derived. The emission rate of the measured toxic gases are derived by the model technique and the results show that the emission amount are in the order of ten to hundred tons per year.

  • PDF

Multi-point Dieless Forming Technology Using Local Heating Effect (국부가열효과를 활용한 다점성형공정기술)

  • Park, J.W.
    • Transactions of Materials Processing
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2022
  • The multi-point dieless forming technology is one of flexible forming technologies that can form 3D curved surfaces of various shapes utilizing a lot of punch arrangements. A new technology that can simultaneously apply high-temperature forming and flexible forming technology by fusing local heating effect to such multi-point dieless forming technology was proposed in the present study. A simple local heating multi-point dieless forming apparatus was fabricated to confirm the applicability of this new technology. This equipment was designed to be used as a heat source by inserting heating cartridges in the head of the multi-point punch. Cartridges were used for all individual punches. Using the manufactured equipment, the time to raise the temperature to the target temperature and the surface temperature of the punch head part in contact with the plate were measured. In addition, forming experiments were carried out according to sheet material temperature (100 ℃, 200 ℃, and 300 ℃) to obtain forming results for each condition. The applicability and feasibility of this technology were confirmed through experimental results.

Washoff Characteristics of Non-point Source pollutants and Estimation of Unit Loads in Suburban Industrial Complex Areas Runoff (교외 산업단지지역 강우유출수내 비점오염물질의 유출특성 및 원단위 산정)

  • Kim, Sung-Joon;Shin, Seon-Mi;Jeon, Yong-Tae;Won, Chan-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.2
    • /
    • pp.315-325
    • /
    • 2012
  • The characteristics of stormwater runoff and estimation of unit loads were examined in suburban industrial complex areas. During rainfall event, the peak concentrations occurred within the first 100 minutes after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in suburban industrial complex. The cumulative load curves for NPS pollutants showed above the straight line, indicating that first flush effect occurred in suburban industrial complex. While the mean TSS, BOD, COD, TN and TP EMCs values were shown the highest values as 120.6 mg/L, 20.8 mg/L, 44.0 mg/L, 5.58 mg/L and 1.46 mg/L respectively. Unit loads estimated from the EMCs were TSS $43.86kg/km^2/day$, COD $52.45kg/km^2/day$, BOD $24.79kg/km^2/day$, T-N $6.65kg/km^2/day$, T-P $1.75kg/km^2/day$, and Pb $0.10kg/km^2/day$. Results of unit loads were compared with the unit pollutant loads from land-use in Korea and USA. The unit load of TSS was lower than that of USA. Estimated BOD and T-N and T-P unit loads were lower than that of Korea.

Development of Multiple Regression Equation for Estimation of Suspended Solids in Unmeasurable Watershed (미계측 유역의 부유물질 산정을 위한 다중회귀식 개발)

  • Choi, Han-Kyu;Park, Jae-Yong;Park, Soo-Jin
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.119-127
    • /
    • 2006
  • The purpose of this study is to present quantitatively the influence of variables that had the largest effect on the changes in suspended solids(SS), which would cause turbid water phenomenon, among water quality factors of the non-point pollution source, and then to develop a multiple regression equation of SS and predict the water quality of ungaged watersheds so as to provide basic data to establish efficient management plans for SS which flow in rivers and lakes. To identify the correlation of SS with the amount of rainfall and the state of land use, a simple correlation analysis and a simple regression analysis were conducted respectively. Finally, a multiple regression analysis was conducted to provide that SS were set as dependent variables while the amount of rainfall, paddy fields and dry fields were set as independent variables. As a result, the amount of rainfall had the most significant influence on changes in SS, followed by dry fields and paddy fields. In addition, the multiple regression equation was developed to predict SS in unmeasurable watersheds.

  • PDF

The runoff characteristics of non-point source to urban stream during rainfall (강우 시 도시 하천으로의 비점오염원 유출특성)

  • Park, Woon-Ji;Kim, Dong-Oog;Ahn, Johng-Hwa;Lee, Chan-Ki
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.83-89
    • /
    • 2007
  • We studied runoff characteristics of combined sewer overflows in a city while it was raining. The event mean concentration (EMC) of biochemical oxygen demand (BOD), chemical oxygen demand ($COD_{Cr}$), suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) in one of the combined sewer sites in Chuncheon was 63.5-211.6 mg/L, 114.9-523.8 mg/L, 70.3-436.4 mg/L, 6.4-33.0 mg/L, and 1.09-6.81 mg/L, respectively. In another combined sewer, the EMC of BOD, COD, SS, TN, and TP was 42.1-131.4 mg/L, 107.7-256.5 mg/L, 33.7-221.1 mg/L, 7.9-26.4 mg/L, and 1.16-3.91 mg/L, respectively. The ratio of the cumulative pollutant mass and the cumulative discharged volume determined using all parameters (BOD, $COD_{Cr}$, SS, TN, and TP) was over 1.0, which shows the first flush effect. Relationships between flow and loadings of BOD, $COD_{Cr}$, SS, TN, and TP were 0.90, 0.89, 0.88, 0.89, 0.92, respectively. Although the size of two areas was almost same, pollutant concentration and loading were different because of the amount of rainfall, rainfall intensity and basin area.

  • PDF

Compensation of Unbalanced PCC Voltage in an Off-shore Wind Farm of PMSG Type Turbines (해상풍력단지에서의 PMSG 풍력발전기를 활용한 계통연계점 불평형 전원 보상)

  • Kang, Ja-Yoon;Han, Dae-Su;Suh, Yong-Sug;Jung, Byoung-Chang;Kim, Jeong-Joong;Park, Jong-Hyung;Choi, Young-Joon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2015
  • This paper proposes a control algorithm for permanent magnet synchronous generators with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage off-shore wind power system under unbalanced grid conditions. Specifically, the proposed control algorithm compensates for unbalanced grid voltage at the PCC (Point of Common Coupling) in a collector bus of an off-shore wind power system. This control algorithm has been formulated based on symmetrical components in positive and negative synchronous rotating reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power is described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of AC input current is injected into the PCC in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm enables the provision of balanced voltage at the PCC resulting in the high quality generated power from off-shore wind power systems under unbalanced network conditions.

A Study on the Method of Air Quality Management Using TCM Model in Industrial Area (군산공업지역의 TCM모형을 적용한 대기오염물질 관리방안에 관한 연구)

  • 김영식;김석재;김동술
    • Journal of Environmental Health Sciences
    • /
    • v.16 no.2
    • /
    • pp.1-10
    • /
    • 1990
  • This study was performed to evaluate a applicability of TCM(Texas Climatological Model) model to a industrial area sush as CUNSAN and a possibility to provide necessary informaitons for air quality management. The air pollutants were measured at 6 sampling sites of GUNSAN industrial area from june to july in 1989. The model was checked by comparing the observed data with estimated data. The meteorological data for wind direction and wind speed were obtained from the observatory station in GUNSAN. The results are summarized as follows. 1. Average concentrations of air pollutants at all sampling sites were SO$_{2}$ 0.011-0.019 ppm. NO$_{2}$ 0.012-0.017 ppm. CO 0.6-1.0 ppm. TSP 45.8-64.2 $\mu$g/m$^{3}$. 2. The emission amounts show that point source are in general higher than area source. 3. As a results of correlation analysis, relationship between SO$_{2}$ concentration in the observed value and estimated value showed positive significance.(r = 0.766) 4. The sulfer content of the 1.6% at present to 0.8%, which means a 53.3% reduction. By controlling stack height could be lowered 14.5%, but the effective way of emission control is use of the lower sulfer fuels than controlling stack height. 5. The ratio between SO$_{2}$ contration in the observed value and estimated value showed 1.05. There-fore, the TCM model was quite effective in predicting air quality in GUNSAN industrial area.

  • PDF

The Design Procedure of Automobile Headlamp Considering User Experience (User Experience를 고려한 자동차 전조등 설계 방안)

  • Kim, Jung-Yong;Yoon, Sang-Young;Min, Seung-Nam;Lee, Ho-Sang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.575-584
    • /
    • 2010
  • The aim of study is to suggest the design procedure of automobile headlamp by considering driver's experience in regard of the visibility and glare during nighttime driving. The characteristics of driver were investigated in terms of the drivers' cognitive ability and reaction time, headlamp specification and visibility, light source and glare. And, the degree of visual discomfort was categorized and recognized as a tool to represent the subjective user experience. The UX point of view was stated when the existing results were seemingly lacking of it. The visual comfort and safety of elderly drivers were also discussed by reviewing the studies of ageing regarding the visibility and driving responses. Finally, this study suggested how to reduce the negative effect of nighttime driving due to the height of headlamp, angle of lighting, color spectrum, discomfort glare, source of light by using the UX perspective and methodology.

Prediction of Water Quality of Youngwol Multipurpose Dam Using FEMWASP (FEMWASP 모형을 이용한 영월 다목적댐의 장래 수질 예측)

  • Kim, Joon Hyun;Han, Young Han
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.443-452
    • /
    • 1998
  • The future water quality of Youngwol Dam was predicted using FEMWASP. In the this study, point and non-point source in the basin was investigated in detail, and future pollutant loading was computed by various prediction technique. The water quality of 29 sites was analyzed over four seasons. FEMWASP was used to predict future water quality of Youngwol lake and downstream of proposed dam. Future water quality of Youngwol lake was predicted to configure eutrophication status, management criteria was suggested to minimize the pollution problems coming from future eutrophication. Discharge rate of dam was decided as 30CMS to conserve the water quality, and overall design of dam was changed.

  • PDF