• 제목/요약/키워드: Industrial Wastewater

검색결과 802건 처리시간 0.03초

생물막 반응조에서 돈사폐수의 유기물 특성 및 동력학계수 산정 (Organic Characteristic of Piggery Wastewater and Kinetic Estimation in Biofilm Reactor)

  • 임재명;한동준;권재혁
    • 산업기술연구
    • /
    • 제16권
    • /
    • pp.51-60
    • /
    • 1996
  • This research was performed for the fundamental data using a advanced treatment process of piggery wastewater. Characteristics of influent wastewater was divided with various methods in fixed biofilm batch reasctor. Fractons of organic were divided into readily biodegradable soluble COD(Ss), slowly biodegradable COD(Xs), nonbiodegradable soluble COD($S_I$), and nonbiodegradable suspended COD($X_I$). Experimental results were summerized as following : i) biodegradable organics fraction in piggery wastewater was about 88.1 percent, and fraction of readily biodegradable soluble COD was about 66.1 percent. ii) Fractions of nonbiodegradable soluble COD was 11~12 percent, and soluble inert COD by metabolism was producted about 6~8 percent. iii) Active biomass fraction of attached biofilm was about 54.7 percent, and substrate utilization rate and maximum specific growth rate of heterotrophs were $8.315d^{-1}$ and $3.823d^{-1}$, respectively.

  • PDF

유동상 Media를 이용한 기존하수처리장의 Retrofitting 가능성 평가 (Evaluation on the Possibility of a Retrofitting Treatment Using Moving Media of Existing Wastewater Treatment)

  • 고태호;박운지;이찬기
    • 산업기술연구
    • /
    • 제25권A호
    • /
    • pp.133-139
    • /
    • 2005
  • In this study, as MBBR(Moving Bed Biofilm Reactor) process using waste tire media is suggested for retrofitting with advanced wastewater treatment and the removal property of organic matter and nutrient and the capacity of media are evaluated through long-term operation with pilot plant following seasons, the application capacity of retrofitting with MBBR process to a existing wastewater treatment is studied. As a result of the long-term operation of the process, it is proved that there is no loss and abrasion of media, and also that it is possible to secure the sufficient attached bio-mass. The values of organic matter and nutrient in effluent are suitable for the strict discharged water quality standards in every season including winter.

  • PDF

고양정 및 저유량을 만족하는 폐수처리용 펌프 설계 최적화 (Design Optimization on Wastewater Treatment Pump of Satisfaction for High Head and Low Flow Rate)

  • 김성;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제33권5호
    • /
    • pp.583-590
    • /
    • 2022
  • In this paper, the performance characteristics of the 2 vane pump for wastewater treatment were investigated using response surface method(RSM) with commercial computation fluid dynamics(CFD) software. Design variables of wastewater treatment pump were defined with the meridional plane of the 2 vane pump impeller. The objective functions were defined as the total head and the efficiency at the design flow rate. The hydraulic performance of optimum model was verified by numerical analysis and the reliability of the model was retained by comparison of numerical analysis and comparative analysis with the reference model.

Comparison of sericin produced through laboratory- and plant-scale extraction

  • Ye Eun Kim;Chun Woo Kim;In Chul Um
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제47권1호
    • /
    • pp.63-71
    • /
    • 2023
  • In this study, the structural characteristics of sericin recovered from wastewater released from the silk textile industry (Plant sericin) were comparatively analyzed with those of sericin extracted from a silkworm cocoon produced in a laboratory (Lab sericin). To prepare Plant sericin, ethanol was added to wastewater (i.e., a sericin aqueous solution) after the degumming process to remove nonprotein materials, affording a sericin precipitate. To prepare Lab sericin, nonprotein materials were removed from a silkworm cocoon and sericin was subsequently extracted from the cocoon. Lab sericin and Plant sericin exhibited similar solution viscosities, gel strengths, and crystallinity indices, indicative of the similar molecular weights (MWs) of the two sericin samples. In the case of sericin powder, Plant sericin was more crystalline than Lab sericin due to its treatment with ethanol. The findings of this study revealed that sericin recovered from industrial wastewater can be used equally as its MW is similar to that of sericin obtained through laboratory-scale extraction.

염색폐수의 전해처리 특성 (Characteristics of Eleclrolytic Treatment of Dye Wastewater)

  • 전법주;윤용수
    • 환경위생공학
    • /
    • 제11권3호
    • /
    • pp.37-46
    • /
    • 1996
  • In this study, the effect of pH, Temp, dye concentration, distance of electrode, and the potential on the removal efficiency of dye-wastewater using electrochemical reaction were investigated. Optimum conditions for the electrochemical treatment of dye-wastewater were obtained that pH;7, 8V, electrode distance; 1cm and the reaction time for obtaining above 99% removal efficiency were 10 - 40min at each conditions, From this result, we can determine the instantaneous current efficiency and specific energy consumption, and we can provide the effective data for economical treatment of industrial dye-wastewater.

  • PDF

Reuse of treated wastewater from steel industry by reverse osmosis membrane: flux decline study

  • Kwon, Tea-Ouk;Lee, Jae-Wook;Moon, Il-Shik
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2004년도 Proceedings of the second conference of aseanian membrane society
    • /
    • pp.199-202
    • /
    • 2004
  • Membrane technology is widely employed as a means of producing various qualities of water from surface water, well water, brackish water and seawater. This is also used in industrial wastewater treatment and its recycling process. A large volume of wastewater is generated by the steel industry. Presently, the treated wastewater from the steel industry cannot be recycled, because some of its components cause either direct or indirect problems.(omitted)

  • PDF

오염부하량 및 유하거리가 인공습지에 의한 폐수처리 효율에 미치는 영향 (Effect of Pollutant Loading and Flow Distance to Wastewater Treatment Efficiency in the Constructed Wetland System)

  • 김형중;김선주;윤춘경
    • 한국농공학회지
    • /
    • 제39권5호
    • /
    • pp.97-108
    • /
    • 1997
  • Natural wastewater treatment systems using the constructed wetland system were evaluated for the wastewater from the industrial complex in rural areas. For the treatment of wastewater from the industrial complex in rural area, a pilot plant of the constructed wetland system was installed at Baeksuk agri-industrial complex in ChunahnCity, Chunchungnam-Do. The experiment with this pilot plants was performed for 1996 and 1997. Results of the study were summarized as follows. For the BOD and COD, when the pollutant loading of them was about 1 3.8g/$m^2$. day (the concentration was l24.0mg/${\ell}$) arid 24.4g/$m^2$.day(the concentration was 220.Omg/${\ell}$), the removal rate of them was high, 90.2% and 93.4%, respectively. For the SS, the effluent concentration was consistently lower than the water quality standard even though the influent concentration varied significantly, which showed that SS was removed by the system effectively which consist of soil and plants. For the T-N and T-P, when the influent pollutant loading of them were moderately high, 2.8g/$m^2$.day to 7.4g/$m^2$. day(concentration 25.0mg/${\ell}$ to 49.7mg/${\ell}$) for T-N and 1.0g/$m^2$.day to 2.6g /$m^2$.day(concentration 8.6mg/${\ell}$ to 14.7mg/${\ell}$) for T-P, the removal rate of them were 86.5% and 94.0%, respectively. The removal rate by the flow distance increased rapidly in the first 4m from the inlet zone, and gradually there after. The width of system was 2m. Overall, the result showed that constructed wetland system is a feasible alternative for the treatment of wastewater from industrial complex in rural areas. Compared to existing systems, this system is quite competitive because it requires low capital cost, almost no energy and maintenance, and therefore, very cost effective.

  • PDF

고농도 니켈을 함유한 산업하수의 질산화율 분석 및 개선 방안 (Analysis and improvement measures of nitrification using industrial wastewater with high Nikel concentration)

  • 임지열;길경익
    • 한국습지학회지
    • /
    • 제19권4호
    • /
    • pp.501-507
    • /
    • 2017
  • 산업하수 내 함유된 고농도 중금속(니켈)은 하수처리장 질산화율 감소의 원인으로 지목되고 있다. 본 연구에서는 고농도 니켈을 함유한 산업하수의 질산화율 분석 및 개선 방안을 도출하고자 실험실 규모 반응조 운전을 실시하였다. 운전 결과를 고농도 니켈을 함유한 경우 질산화율은 20% 내외로 낮은 범위를 보였지만, 저농도 니켈이 유입되었을 경우 질산화율이 향상(70% 이상)되었다. 질산화율의 차이를 보인 주요 원인은 니켈이 반응조 내 미생물의 활성을 감소시킨 것으로 AUR과 SNR 분석을 통해 나타났다. 또한 고농도 니켈이 유입될 경우, 체류시간 증가와 더불어 질산화율이 증가하였다. 즉, 고농도 중금속(니켈)을 함유한 하수의 경우 미생물 관리 및 체류시간 증가를 통해 안정적인 질산화율을 확보할 수 있을 것으로 판단된다.

미생물막 유동층 반응기를 이용한 산업폐수 처리에 관하여 (The Treatment of Industrial Wastewater by the Fluidized-Bed Biofilm Reactor)

  • 서명교;서정호;강준수
    • 한국식품과학회지
    • /
    • 제25권1호
    • /
    • pp.69-77
    • /
    • 1993
  • 미생물막 유동층 반응기로 염료공장 폐수의 유기물 처리효율을 고찰하였다. 공장폐수를 2배, 3배 및 6배 희석하여 처리하였던 바, 각 희석배율 모두 F/M비가 0.2에서 0.3으로 증가할 때 처리효율이 급격히 낮아졌다. 한편, 같은 F/M비에서는 희석율이 높을수록 처리효율이 높았으며 수리학적 체류시간이 증가함에 따라서 처리효율도 증가하였다. 6배 희석시 F/M비가 0.2 이하에서 BOD 처리효율이 $90{\sim}97%$로 가장 좋았다. 또 반응기 설계를 위한 통역학적 계수 Y, $k_b$값 및 상관계수 r은 2배 희석시 $Y=0.3365\;k_d=0.03782\;day^{-1}\;r=0.997$, 3배 희석시 $Y=0.3341\;k_d=0.0275\;day^{-1}\;r=0.996$ 및 6배 희석시는 $Y=0.5460\;k_d=0.03434\;day^{-1}\;r=0.998$로 나타났다.

  • PDF

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • 공업화학
    • /
    • 제33권5호
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.