• Title/Summary/Keyword: Industrial Motor

Search Result 1,336, Processing Time 0.028 seconds

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.1
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

Exposure Assessment of Black Carbon among Tollbooth Worker at a University (서울시 소재 대학교 차량 요금정산소 수납원의 블랙카본 노출 평가)

  • Kim, Dongwon;Jo, Hyeri;Woo, Cheolwoon;Ryu, Seung-Hun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.464-476
    • /
    • 2019
  • Objectives: This study aimed to assess the exposure levels of tollbooth workers to diesel particulate matter using black carbon (BC) and to find the correlations among variables associated with BC using the motor vehicle management act regulated by the Ministry of Land, Infrastructure and Transport. Methods: This study was performed over 14 days at a university in Seoul. BC levels were monitored using an aethalometer and were conducted around the breathing zones of the workers. There were three sampling locations: inside the tollbooth (front gate and rear gate) and an office as a control group. T-test, correlation, and multiple linear regression analysis were performed using SPSS. Results: The geometric mean (GM) of BC30min concentrations in the exposure group was 2.44 ㎍/㎥, approximately 1.4 times higher than the control group (1.75 ㎍/㎥). The GM of BC30min concentrations was 2.75 ㎍/㎥ during the heavy traffic time (9-10 am) and 2.30 ㎍/㎥ during non-heavy traffic times (p<0.001). The multiple linear regression analysis shows that the number of all types of vehicles and PM2.5 concentrations in the atmosphere were factors increasing the GM of BC(ln(BC30min)) concentrations (adjusted R2=0.42, p<0.001). The workers were constantly exposed to low concentrations (GM of BC30min=2.44 ㎍/㎥), but they were exposed to peak concentrations instantly (BC10sec=3545.04 ㎍/㎥). When the GM of BC30min concentrations was momentarily represented as high, it was identified that a vehicle mainly using diesel fuel or an aging vehicle had passed. Conclusions: A ventilation system should be installed in the closed tollbooth or aging vehicles should be controlled so as not to pass tollbooths.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.

Removal of Volatile Organic Compounds (VOCs) of Deodorant by Adding a Metal Oxide to the Essential Oils (식물정유물질에 금속산화물을 첨가한 탈취제의 휘발성유기화합물질의 제거에 관한 연구)

  • Lim, You-Young;Lee, Min-Ho;Jeon, Soo-Bin;Yang, Kyeong-Soon;Jeong, Hae-Eun;Oh, Kwang-Joong
    • Clean Technology
    • /
    • v.22 no.2
    • /
    • pp.96-105
    • /
    • 2016
  • VOCs emissions from industries cause the air pollution and odor. In the industrial facilities, the existing odor treatment techniques have limits and problems. In this study, the optimum essential oil and metal oxide selected by screening test. lavender oil, cypress oil and TiO2 were determined by deodorant materials and those were blended by 5%, 45%, 10%, respectively. In addition, the result of batch type experiments depending on the dilution rate, injection, rate, temperature showed that the optimum condition of deodorant is 6 mL of injection rate, and 200 times of dilution rate and the removal efficiency increased in proportion with temperature. In addition, the activation energy was calculated from the rate equation, which appeared in the 3-4 times lower than conventional deodorants.

A Study on the Analysis of Polycyclic Aromatic Hydrocarbons in Air (대기중 다환 방향족 탄화수소류의 분석에 관한 연구)

  • Pyo, Hee-Soo;Hong, Jee-Eon;Lee, Kang-Jin;Park, Song-Ja;Lee, Won
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.453-465
    • /
    • 2000
  • Polycyclic aromatic hydrocarbons (PAHs) were produced by thermoreaction (incompletely combustion) of organic compounds such as fuel, gasoline, diesel etc, and were known the strong carcinogenic compounds. In our country, a study for health risk assessment of PAHs in air were needed according to rapidly increasing of motor vehicle and progressing to industrial country. In this study, concentrations of PAHs in 263 air samples of fourteen sites-Seoul, Pusan, etc-according to four times sampling for one year are measured by GC/MSD for basic research for health risk assessment. As the result, 14 PAHs are detected in all samples and annual average concentration of total PAHs was $28.72ng/m^3$ and highest average concentration of total PARs was $47.76ng/m^3$ in winter season. The concentrations of total PAHs are proportioned to amount of extracted organic material (EOM). The average concentration of total PAHs in EOM was 0.28%.

  • PDF

Studies on Photoprotection of Walnut Veneer Exposed to UV Light (자외선 노출에 의한 Walnut 베니어의 광 변색 방지 연구)

  • Park, Se-Yeong;Hong, Chang-Young;Kim, Seon-Hong;Choi, June-Ho;Lee, Hyo-Jin;Choi, In-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.221-230
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of several chemical treatments to prevent photodegradation of wood veneer by external UV (Ultraviolet) light. Of woods, walnut veneer is selected as a raw material for this study since it is known as a luxurious wood with dark color giving an esthetic effect. Alcohol-benzene, hydrogen peroxide ($H_2O_2$) and sodium hypochlorite (NaClO) solution were used for investigate the effect on color stabilization. Despite the removal of the extractive compounds, which is known as a discoloration component, a significant color change of walnut wood veneer was observed. Meanwhile, the veneers treated by 20 and 30% $H_2O_2$ solution at $75^{\circ}C$ for 1 h also showed the no positive effect of color stability exposed to UV light although they have a bleaching effect on wood veneer. Besides, it was difficult to maintain the original color of walnut veneer due to the elution of the extractive compounds. On the other hands, the veneer treated by NaClO solution indicated the good performance on color stability despite of the intensive UV light test. However, when the concentration exceeds 3%, surface roughness and fiber damage occurred simultaneously. Therefore, the walnut species should be treated with proper concentration when sodium hypochlorite is applied to the veneer.

Remote Sensing of Atmospheric Trace Species using Multi Axis Differential Optical Absorption Spectroscopy (Multi Axis DOAS를 이용한 대기미량 물질 원격 측정)

  • Lee Chul-Kyu;Kim Young-Joon
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.141-151
    • /
    • 2006
  • UV-visible absorption measurement techniques using several horizone viewing directions in addition to the traditional zenith-sky pointing have been recently developed in ground-based remote sensing of atmospheric constituents. The spatial distribution of various trace gases close to the instrument can be derived by combing several viewing directions. Multi-axis differential optical absorption spectroscopy (MAX-DOAS) technique, one of the remote sensing techniques for air quality measurements, uses the scattered sunlight as a light source and measures it at various elevation angles (corresponding to the viewing directions) by sequential scanning with a stepper motor. A MAX-DOAS system developed by GIST/ADEMRC has been applied to measuring trace gases in urban air and plumes of the volcano and fossil fuel power plant in January, May, and October 2004, respectively. MAX-DOAS spectra were analyzed to identify and quantify $SO_2,\;NO_2,\;BrO,\;and\;O_4$ (based on Slant Column Densities, SCD) in the urban air, volcanic plume, and fossil fuel power plant utilizing theirs specific structured absorption features in the UV-visible region. Vertical scan through the multiple elevation angles was performed at different directions perpendicular to the plume dispersion to retrieve cross-sectional distribution of $SO_2\;or\;NO_2$ in the plumes of the volcano and fossil fuel power plant. Based on the estimated cross sections of the plumes the mixing ratios were estimated to 580 $SO_2$ ppbv in the volcanic Plume, and 337 $NO_2\;and\;227\;SO_2$ ppbv in the plume of the fossil fuel power plant, respectively.

The Perception Analysis of Autonomous Vehicles using Network Graph (네트워크 그래프를 활용한 자율주행차에 대한 인식 분석)

  • Hyo-gyeong Park;Yeon-hwi You;Sung-jung Yong;Seo-young Lee;Il-young Moon
    • Journal of Practical Engineering Education
    • /
    • v.15 no.1
    • /
    • pp.97-105
    • /
    • 2023
  • Recently, with the development of artificial intelligence technology, many technologies for user convenience are being developed. Among them, interest in autonomous vehicles is increasing day by day. Currently, many automobile companies are aiming to commercialize autonomous vehicles. In order to lay the foundation for the government's new and reasonable policy establishment to support commercialization, we tried to analyze changes and perceptions of public opinion through news article data. Therefore, in this paper, 35,891 news article data mentioning terms similar to 'autonomous vehicles' over the past three years were collected and network analyzed. As a result of the analysis, major keywords such as 'autonomous driving', 'AI', 'future', 'Hyundai Motor', 'autonomous driving vehicle', 'automobile', 'industrial', and 'electric vehicle' were derived. In addition, the autonomous vehicle industry is developing into a faster and more diverse platform and service industry by converging with various industries such as semiconductor companies and big tech companies as well as automobile companies and is paying attention to the convergence of industries. To continuously confirm changes and perceptions in public opinion, it is necessary to analyze perceptions through continuous analysis of SNS data or technology trends.

A Strategy of a Gap Block Design in the CFRP Double Roller to Minimize Defects during the Product Conveyance (제품 이송 시 결함 최소화를 위한 CFRP 이중 롤러의 Gap block 설계 전략)

  • Seung-Ji Yang;Young-june Park;Sung-Eun Kim;Jun-Geol Ahn;Hyun-Ik Yang
    • Composites Research
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2024
  • Due to the structural characteristic of a double roller, the double roller can have various deformation behaviors depending on a gap block design, even if dimensions and loading conditions for the double roller are the same. Based on this feature, we propose a strategy for designing the gap block of the carbon-fiber reinforced plastic (CFRP) double roller to minimize defects (e.g., sagging and wrinkling), which can be raised during the product conveying process, with the pursue of the lightweight design. In the suggested strategy, analysis cases are first selected by considering main design parameters and engineering tolerances of the gap block, and then deformation behaviors of these selected cases are extracted using the finite element method (FEM). Here, to obtain the optimal gap block parameters that satisfy the purpose of this study, deformation deviations in the contact area are calculated and compared using the extracted deformation behaviors. Note that the contact area in this work is located between the product and the roller. As a result, through the design method of the gap block proposed in this work, it is possible to construct the CFRP double roller that can significantly decrease the defects without changing the overall sizes of the roller. A detailed method is suggested herein, and the results are evaluated in a numerical way.

Analysis of the Association between Air Pollutant Distribution and Mobile Sources in Busan Using Spatial Analysis (공간 분석을 통한 부산광역시 대기오염물질의 분포와 이동오염원 간의 관련성 연구)

  • Jae-Hee Min;Byoung-Gwon Kim;Hyunji Ju;Na-Young Kim;Yong-Sik Hwang;Seungho Lee;Young-Seoub Hong
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.191-200
    • /
    • 2024
  • Background: Busan is a rapidly industrializing city with many mixed residential and industrial areas. Fine dust emissions from mobile pollution sources such as ships and vehicles are particularly high in Busan. Objectives: This study analyzed the spatial distribution of air pollutants over the past three years and identified the impact of air pollutants through mobile source data in Busan. Methods: We obtained air pollutant data on fine particulate matter (PM10), ultrafine particulate matter (PM2.5), nitrogen dioxide (NO2), sulfurous acid gas (SO2), and ozone (O3) for the last three years (source: airkorea.or.kr) and analyzed the spatial distribution using SAS 9.4 and Surfer 23. For the mobile pollutant data, we used CCTV data from major intersections in Busan to identify truck and car traffic, and visualized traffic density with QGIS. Results: The analysis of the concentration of air pollutants over three years (2020~2022) showed that all were lower than the annual environmental standards with the exception of PM2.5. PM10 and PM2.5 were found to be highly concentrated in the western part of the area, while NO2 was high in the port area of Busan and SO2 was high in the western part of the area and near the new port of Busan. In the case of O3, it was high in the eastern part of the city. The traffic volume of freight vehicles by intersection was concentrated in the West Busan area, and the traffic volume for all cars was also confirmed to be concentrated at "Mandeok Intersection" located in the West Busan area. Conclusions: This study was conducted to determine the relationship between air pollutants emitted from motor vehicles and the distribution of air pollutants in Busan. The spatial distribution of PM10 and PM2.5 correlates with traffic volume, while high concentrations of SO2 and NO2 near the port are associated with ship emissions.