• Title/Summary/Keyword: Inductive link

Search Result 30, Processing Time 0.021 seconds

Improved Active Power Filter Performance Based on an Indirect Current Control Technique

  • Adel, Mohamed;Zaid, Sherif;Mahgoub, Osama
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.931-937
    • /
    • 2011
  • This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.

Graphical Analysis and Design for Asymmetric Energy Link in Series- Series Configuration of Inductive Power Transfer (비대칭 직렬 보상형 자계결합 무선전력전송의 도식적인 에너지링크 분석 및 설계 방법)

  • Jeong, Chae-Ho;Choi, Hee-Su;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.200-201
    • /
    • 2017
  • 무선전력전송 시스템의 전력 수신부는 많은 경우 송신부에 비해 크기가 작으므로 자계결합 에너지링크 코일의 권선을 비대칭으로 설계할 필요가 있다. 본 논문은 직렬 공진 보상 구조의 자계결합 무선전력전송에서 에너지링크 전압이득과 전력전송효율을 동시에 고려해 전력변환회로 관점에서의 비대칭 코일의 도식적인 분석 및 설계 방법을 제안한다. 제안하는 설계평면을 통해 에너지링크 코일의 정렬이 어긋날 때 혹은 부하요구가 변할 때 에너지링크의 전압이득과 전력전송효율 변화를 직관적으로 예측할 수 있으며 주어진 설계조건에 따라 에너지 링크를 간단히 설계할 수 있다. 본 제안방법은 회로 시뮬레이션을 통해 검증 되었다.

  • PDF

Fuzzy Pre-Compensated PI Control of Active Filters

  • Singh, Bhim;Singhal, Varun
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This paper deals with a new and improved control technique for shunt active filters (AF) used for compensating unwanted harmonic currents injected in the mains due to nonlinear varying loads. This work is motivated by the need to find a permanent solution to the rigorous hit and trial method for evaluating system parameters in an indirect control of AF. A fuzzy pre-compensated PI (Proportional-Integral) controller is used to fuzzify the reference DC voltage of AF to the controller input so that the overshoots and undershoots in its DC link voltage are minimized and the settling time is improved. A three-phase diode rectifier with R-L (Resistive-Inductive) load is used as a non-linear load to study the effectiveness of the proposed controller of the AF. Robustness to filter parameter variations, insensitivity to controller parameter variations, and transient response has been taken as performance evaluation parameters. The results are shown through simulations in Matlab using power system block sets to demonstrate the capability of the proposed controller of the AF.

Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter (Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계)

  • Baek, Seung-Hyuk;Kim, Sungmin;Lee, Jaehong;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

Development of a wireless telemetry system based on MICS standard (MICS 표준에 기반한 무선 텔레메트리 시스템 개발)

  • Lee, Seung-Ha;Park, Il-Yong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • It is said that the desirable bio-signal measurement and stimulation system should be an implantable type if the several problems such as biocompatibility, electrical safety, and so on are overcome. In addition to the biocompatibility issue, a robust RF communication and a stable electrical power source for the implantable bio-signal measurement and stimulation system are very important matters. In this paper, a wireless telemetry system which adopts the FCC's approved MICS (medical implant communication service) protocol and a wireless power transmission has been proposed. The proposed system composed of a base station (BS) and an implantable medical device (IMD) has the advantages that the interference with other RF devices can be reduced by the use of the specially assigned MICS frequency band of 402.MHz to 405 MHz. Also, the proposed system includes various functions of a multi-channel bio-signal acquisition and an electric stimulation. Since the electrical power for the IMD can be provided by the inductive link between PCB patterned coils, the IMD needs no battery so that the IMD can be smaller size and much less dangerous than the active type IMD which includes the internal battery. Finally, the validity as a wireless telemetry system has been demonstrated through the experiments by using the implemented BS and IMD.

Design of MAGLEV Information Transmission System by Radio Inductive Loop (유도무선루프에 의한 자기부상열차 정보전송 시스템의 설계)

  • An, Sang-Gwon;Park, Seok-Ha;Park, Jeong-Su;Kim, Jong-Beom;Kim, Yang-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.1
    • /
    • pp.42-47
    • /
    • 1999
  • This paper presents the information transmission between on-board and ground-site in MAGLEV. considering safety and high speed operation and density operation, information transmission between them is necessary. Therefore it is necessary for transmission system to ensure high speed transmission, low error rate, massive information, and reliability of information. To provide above conditions, 1.1km signal line assembly was constructed and Frequency Shift Keying(FSK) modulation and Open System Interconnection(OSI) based high-level data link control(HDLC) protocol are applied. To modulate digital signal for transmission from ground-site to on-board, carrier frequency of 70kHz is used and 90khz is used for transmission from on-board to ground-site. Transmission speed is 2400bps for consideration of train speed, quantity of information, and data error rate. And this paper introduces information monitoring considering user interface and presents the method for an effective data transmission in MAGLEV which is now being tested and intends to provide for an intelligent train operation system in future.

  • PDF

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

A Novel Induction Heating Type Super Heated Vapor Steamer using Dual Mode Phase Shifted PWM Soft Switching High Frequency Inverter

  • Sugimura, Hisayuki;Eid, Ahmad;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.774-777
    • /
    • 2005
  • In this paper, a constant frequency phase shifting PWM controlled voltage source full bridge-type series load resonant high-frequency inverter using the IGBT power modules is presented for innovative consumer electromagnetic induction heating applications such as a hot water producer, steamer and super heated steamer. The full bridge arm side link passive quasi-resonant capacitor snubbers in parallel with the each power semiconductor device and high frequency AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is discussed and evaluated on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency soft switching PWM inverter topology, what is called class DE type. including the variable-power variable-frequency(VPVF) regulation function can expand zero voltage soft switching commutation range even under low output power setting ranges, which is more suitable and acceptable for induction heated dual packs fluid heater developed newly for consumer power utilizations. Furthermore, even in the lower output power regulation mode of this high-frequency load resonant tank high frequency inverter circuit it is verified that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.

  • PDF

A Flyback Transformer linked Soft Switching PWM DC-DC Power Converter using Trapped Energy Recovery Passive Quasi-Resonant Snubbers with an Auxiliary Three-Winding Transformer

  • Ahmed Tarek;Chandhaket Srawouth;Nakaoka Mutsuo;Jung Song Hwa;Lee Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.237-245
    • /
    • 2004
  • In this paper, a two-switch high frequency flyback transformer linked zero voltage soft switching PWM DC-DC power converter implemented for distributed DC- feeding power conditioning supplies is proposed and discussed. This switch mode power converter circuit is mainly based on two main active power semiconductor switches and a main flyback high frequency transformer linked DC-DC converter in which, two passive lossless quasi-resonant snubbers with pulse current regeneration loops for energy recovery to the DC supply voltages composed of a three winding auxiliary high frequency pulse transformer, auxiliary capacitors and auxiliary diodes for inductive energy recovery discharge blocking due to snubber capacitors are introduced to achieve zero voltage soft switching from light to full load conditions. It is clarified that the passive resonant snubber-assisted soft switching PWM DC-DC power converter has some advantages such as simple circuit configuration, low cost, simple control scheme, high efficiency and lowered noises due to the soft switching commutation. Its operating principle is also described using each mode equivalent circuit. To determine the optimum resonant snubber circuit parameters, some practical design considerations are discussed and evaluated in this paper. Moreover, through experimentation the practical effectiveness of the proposed soft switching PWM DC-DC power converter using IGBTs is evaluated and compared with a hard switching PWM DC-DC power converter.

The Perceived Causal Structure Model on Stress Experienced by Nursing Students during Clinical Practice (간호학생의 임상실습스트레스에 관한 인지적 인과구조모형)

  • Park, Mi-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.10 no.1
    • /
    • pp.54-63
    • /
    • 2004
  • The purpose of this study is to identify the factors that influence stress experienced by nursing students and to provide a perceived causal structure model among these variables. The ultimate goal of this study is to develop efficient guidance to clinical nursing education in this population. This study intends to apply perceived causal structure: network analysis method which was developed by Kelly(1983), and has been applied in nursing research. This method is selected to show dynamic relationship of stressor using network method. Data was collected from convenient sample of 186 junior college nursing students who had the clinical practice experience during 10 weeks. Data collection and analysis was conducted in 2 steps from December, 9, 2002 to February, 8, 2003. Step 1.: Data was collected using literature review(10 articles) to identify the causes of stress. Nine causes of stress were extracted. Step 2.: As perceived casual structure network study, data was collected using questionnaires which included 9 extracted cause and stress. The questionnaire contained a 10 X 10 grid table with 10 causes and effects printed. In network analysis, 'Yes' was scored as 1, 'No' was scored as 0, and the mean(maximum 1, minimum 0) was calculated. Construction of the network under inductive eliminative analysis which stopped the construction of the network when the consensual agreement level dropped near 50% was proceeded by adding causes in order of the mean rating level. In this study, construction of the final network was stopped by consensual agreement level of 52% of the total subjects. The results are summarized as follows : Step 1: Investigation of the causes of stress ; The extracted causes of stress from quality data was identified 9 categories ; negative nurse, lack of clinical practice opportunity, ambiguous role, negative patient, lack of nursing knowledge and skill, difficult of personal relations, inefficient clinical practice guidance, gap of theory and practice, lack of support. Step 2 : Construction of the perceived causal structure model ; 1) The most central cause of stress is ambiguous role in the systems of causation. 2) The distal cause of stress is inefficient clinical practice guidance 3) The causes that have a number of outgoing link are negative nurse, ambiguous role. 4) The causes that have a number of incoming link are ambiguous role, gap of theory- practice, lack of clinical practice opportunity, lack of nursing knowledge- skill. 5) There is a mutual relationship between stress and difficult of personal relations, stress and ambiguous role, ambiguous role and negative nurse, ambiguous role and lack of clinical practice opportunity, ambiguous role and lack of nursing knowledge-skill, lack of nursing knowledge-skill and gap of theory- practice. In conclusion, the network suggests that the first centre cause is related on ambiguous role and the second on negative nurse, inefficient clinical practice guidance in the systems of causation

  • PDF