• Title/Summary/Keyword: Inductive Noise

Search Result 50, Processing Time 0.036 seconds

A Study on the Start-up Control for HDD Spindle Motors (HDD 스핀들 모터의 초기 구동 제어에 관한 연구)

  • Jeong, Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.869-873
    • /
    • 2008
  • Optimization method for the open loop commutation time intervals in HDD spindle start-up control is presented in this paper. A hard disk drive(HDD) uses a sensorless brushless DC motor(BLDC) for the platter rotation. Because there is no direct sensor for the rotor position, open loop commutations after sensing the rotor position at a standstill using inductive sensing method are performed to speed up the rotor up to a certain speed where the zero crossings of the back electromotive force(EMF) are measurable. Therefore successful open loop commutations are necessary for the stable start-up control of the spindle motors. Random neighborhood search(RNS) algorithm is introduced as a optimization technic in this paper. Rotor speed and its standard deviation are used as a cost function and commutation intervals obtained from the spindle motion equation are used as initial parameter values for the RNS. With the help of the proposed method optimized open loop commutation time intervals for the very low start-up current are acquired and tested. The experimental results shows that the proposed method can decrease the start-up failure rate of a HDD spindle motor.

  • PDF

Construction and Operation of High-$T_c$ Scanning SQUID Microscope

  • Baeka, B.;Kim, Ho-chul;Khim, Z.G.;Lee, S.M.;Moon, S.H.;Oh, B.
    • Progress in Superconductivity
    • /
    • v.1 no.1
    • /
    • pp.20-25
    • /
    • 1999
  • We constructed a high-$T_c$ scanning SQUID microscope (SSM) operating in the liquid nitrogen. We used a washer-type YBCO SQUID with inner and outer dimensions of $12{\mu}m$ and $36{\mu}m$, respectively, which was grown on the $SrTiO^3$ bicrystal substrate. The sample, rather than SQUID, was scanned using two stepping motors. We also developed readout electronics, stepping motor controller, and the software for system control and data display. We took images of various samples using our SSM and found that the spatial resolution is about $40{\mu}m$ and noise level is lower than $10^{-7}T/{\surd}Hz$ at 100 Hz and higher at lower frequencies. The noise level was much higher than that of a typical SQUID due to the other coupling from the electric parts. We present a simple argument on the inductive coupling between the sample and the SQUID which should be under-stood for the proper interpretation of the obtained images. By comparing the measured data with the simulation results the gap between the SQUID and the sample is estimated to be $40{\mu}m$.

  • PDF

An Experimental Study on PWR Nuclear Fuel Assembly Vibration (경수로 핵연료집합체 진동의 실험적 고찰)

  • 장영기;김규태;조규종
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.82-87
    • /
    • 2003
  • Nuclear fuel with a big slenderness ratio is susceptible to flow-induced vibration under very severe conditions of high temperature, high flow and exposure to irradiation in nuclear reactor. The fuel assembly should, therefore, be designed to escape any resonance due to the vibration during the reactor operation, in particular, in case of the design changes. In addition, the amplitudes due to the grid vibration, the fuel rod vibration and the fuel assembly vibration should be minimized to reduce the grid-to-rod fretting wear. Fuel assembly vibration tests in air at room temperature and in water at high temperature have been performed to investigate fuel vibration behaviors. The frequency and damping during the test in air have been compared to those in water. Through the hydraulic test, the advanced assembly has been evaluated not to be susceptible to any resonance. In addition, the test data from the tests can be used to make fuel model and to evaluate grid-to-rod fretting wear.

  • PDF

6.2~9.7 GHz Wideband Low-Noise Amplifier Using Series RLC Input Matching and Resistive Feedback (직렬 RLC 입력 정합 및 저항 궤환 회로를 이용한 6.2~9.7 GHz 광대역 저잡음 증폭기 설계)

  • Park, Ji An;Cho, Choon Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1098-1103
    • /
    • 2013
  • A low-noise amplifier(LNA) using series RLC matching network and resistive feedback at 8 GHz is presented. Inductive degeneration is used for the input matching with which the proposed LNA shows quite a wide bandwidth in terms of $S_{21}$. An equivalent circuit model is deduced for input matching by conversion from parallel circuit to series resonant circuit. By exploiting the resistive feedback and series RLC input matching, fully integrated LNA achieves maximum $S_{21}$ of 8.5 dB(peak to -3 dB bandwidth is about 3.5 GHz) noise figure of 5.9 dB, and IIP3 of 1.6 dBm while consuming 7 mA from 1.2 V supply.

A High Linear And Low Noise COMOS RF Front-End For 2.4GHz ZigBee Applications (지그비(ZigBee) 응용을 위한 고선형, 저잡음 2.4GHz CMOS RF 프론트-엔드(Front-End))

  • Lee, Seung-Min;Jung, Chun-Sik;Kim, Young-Jin;Baek, Dong-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.604-610
    • /
    • 2008
  • A 2.4 GHz CMOS RF front-end using for ZigBee application is described The front-end consists of a low noise amplifier and a down-mixer and uses a 2 MHz IF frequency. A common source with resistive feedback and an inductive degeneration are adopted for a low noise amplifier, and a 20 dB gain control step is digitally controlled. A passive mixer for low current consumption is employed. The RF front-end is implemented in 0.18 ${\mu}m$IP6M CMOS process. The measured performance is 4.44 dB NF and -6.5 dBm IIP3 while consuming 3.28 mA current from a 1.8 V supply.

  • PDF

Design of MMIC Low Noise Amplifier for B-WLL using GaAs PHEMT (GaAs PHEMT를 이용한 B-WLL용 MMIC 저잡음 증폭기의 설계)

  • 김성찬;이응호;조희철;조승기;김용호;이진구
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.102-109
    • /
    • 2000
  • In this paper, a Low Noise Amplifier for B-WLL was designed using the MMIC technology with GaAs PHEMTs fabricated at our lab. The PHEMT for LNA has a $0.35\mu\textrm{m}$ gate and a total gate width of $120\mu\textrm{m}$. The designed MMIC LNA consists of three stages. The first stage of the LNA has a series inductive feedback for obtaining minimum noise and high stability as well. And the designed MMIC LNA has not an interstage matching circuit between the second and the third stage for minimization of the chip size. From simulation results, noise figure and S21 gain of the designed MMIC LNA are 0.85~1.25 dB and 22.08~23.65 dB in the frequency range of 25.5~27.5 GHz respectively. And the chip size is $3.7\times1.6 mm^2$.

  • PDF

Development of Sensor for Magnetically Levitated High Speed Spindle System (자기 부상 고속 주축계의 센서 개발)

  • Shin, Woo-Cheol;Lee, Dong-Ju;Hong, Jun-Hee;Noh, Myoung-Gyu
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.987-992
    • /
    • 2000
  • In a high speed spindle system, it is very important to monitor the operation of the spindle to prevent catastrophic damage to the system. Widely used sensors for monitoring are eddy-current and capacitive types. These sensors provide high accuracy of monitoring, but their steep prices lead to expensive high speed spindle systems. The main goal of our research is to develop technology for producing high speed spindle system utilizing magnetic bearings. As active magnetic bearings require position sensors for feedback control, a noncontact position sensor is being developed as a part of this main goal. Once developed, it will contribute to affordable high speed spindle system. This paper describes the selection process of the sensor types and the design of the driving circuit. We also report the experimental results that characterize the static and dynamic performances of the inductive sensor.

  • PDF

RF Plasma Processes Monitoring for Fluorocarbon Polluted Plasma Chamber Cleaning by Optical Emission Spectroscopy and Multivariate Analysis (Optical Emission Spectra 신호와 다변량분석기법을 통한 Fluorocarbon에 의해 오염된 반응기의 RF 플라즈마 세정공정 진단)

  • Jang, Hae-Gyu;Lee, Hak-Seung;Chae, Hui-Yeop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.242-243
    • /
    • 2015
  • Fault detection using optical emission spectra with modified K-means cluster analysis and principal component anal ysis are demonstrated for inductive coupl ed pl asma cl eaning processes. The optical emission spectra from optical emission spectroscopy (OES) are used for measurement. Furthermore, Principal component analysis and K-means cluster analysis algorithm is modified and applied to real-time detection and sensitivity enhancement for fluorocarbon cleaning processes. The proposed techniques show clear improvement of sensitivity and significant noise reduction when they are compared with single wavelength signals measured by OES. These techniques are expected to be applied to various plasma monitoring applications including fault detections as well as chamber cleaning endpoint detection.

  • PDF

Zero-Phase Angle Frequency Tracking Control of Wireless Power Transfer System for Electric Vehicles using Characteristics of LCCL-S Topology (LCCL-S 토폴로지 특성을 이용한 전기자동차용 무선충전시스템의 ZPA 주파수 추종 제어)

  • Byun, Jongeun;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.404-411
    • /
    • 2020
  • Inductive power transfer (IPT) systems for electric vehicles generally require zero phase angle (ZPA) frequency tracking control to achieve high efficiency. Current sensors are used for ZPA frequency tracking control. However, the use of current sensors causes several problems, such as switching noise, degrading control performance, and control complexity. To solve these problems, this study proposes ZPA frequency tracking control without current sensors. Such control enables ZPA frequency tracking without real-time control and achieves stable zero voltage switching operation closed to ZPA frequency within all coupling coefficient and load ranges. The validity of the proposed control algorithm is verified on LCCL-S topology with a 3.3 kW rating IPT experimental test bed. Simulation verification is also performed.

Plasma Impedance Monitoring with Real-time Cluster Analysis for RF Plasma Etching Endpoint Detection of Dielectric Layers

  • Jang, Hae-Gyu;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.123.2-123.2
    • /
    • 2013
  • Etching endpoint detection with plasma impedance monitoring (PIM) is demonstrated for small area dielectric layers inductive coupled plasma etching. The endpoint is determined by the impedance harmonic signals variation from the I-V monitoring system. Measuring plasma impedance has been examined as a relatively simple method of detecting variations in plasma and surface conditions without contamination at low cost. Cluster analysis algorithm is modified and applied to real-time endpoint detection for sensitivity enhancement in this work. For verification, the detected endpoint by PIM and real-time cluster analysis is compared with widely used optical emission spectroscopy (OES) signals. The proposed technique shows clear improvement of sensitivity with significant noise reduction when it is compared with OES signals. This technique is expected to be applied to various plasma monitoring applications including fault detections as well as end point detection.

  • PDF