• Title/Summary/Keyword: Induction pump

Search Result 103, Processing Time 0.033 seconds

ANALYSES OF ANNULAR LINEAR INDUCTION PUMP CHARACTERISTICS USING A TIME-HARMONIC FINITE DIFFERENCE ANALYSIS

  • Seong, Seung-Hwan;Kim, Seong-O
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.213-224
    • /
    • 2008
  • The pumping of coolant in a liquid metal fast reactor may be performed with an annular linear induction electro-magnetic (EM) pump. Linear induction pumps use a traveling magnetic field wave created by poly-phase currents, and the induced currents and their associated magnetic field generate a Lorentz force, whose effect can be the pumping of the liquid metal. The flow behaviors in the pump are very complex, including a time-varying Lorentz force and pressure pulsation, because an induction EM pump has time-varying magnetic fields and the induced convective currents that originate from the flow of the liquid metal. These phenomena lead to an instability problem in the pump arising from the changes of the generated Lorentz forces along the pump's geometry. Therefore, a magneto-hydro-dynamics (MHD) analysis is required for the design and operation of a linear induction EM pump. We have developed a time-harmonic 2-dimensional axisymmetry MHD analysis method based on the Maxwell equations. This paper describes the analysis and numerical method for obtaining solutions for some MHD parameters in an induction EM pump. Experimental test results obtained from an induction EM pump of CLIP-150 at the STC "Sintez," D.V. Efremov Institute of Electro-physical Apparatus in St. Petersburg were used to validate the method. In addition, we investigated some characteristics of a linear induction EM pump, such as the effect of the convective current and the double supply frequency (DSF) pressure pulsation. This simple model overestimated the convective eddy current generated from the sodium flow in the pump channel; however, it had a similar tendency for the measured data of the pump performance through a comparison with the experimental data. Considering its simplicity, it could be a base model for designing an EM pump and for evaluating the MHD flow in an EM pump.

A Study on the Development of 34kW class Cryogenic Induction Motor using LNG Pump (34kW급 LNG펌프용 극저온 유도전동기 개발에 관한 연구)

  • Lee, Ki-Wook;Jeong, Dong-Wook;Park, Gwan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.999-1004
    • /
    • 2015
  • In this paper, the study presents the development of 34kW class cryogenic induction motor using LNG Pump. Operating temperature of an induction motor using LNG Main Cargo Pump is at −163℃. Due to variation of the resistivity, these motor have different torque characteristics. So, it should design to considering the resistivity change. The most important consideration of induction machine operating is cryogenic temperature. If the temperature rise, LNG is vaporized. it is a major cause of pump failure. There are several causes of heat source like coreloss, hysterisysloss, copperloss. This paper analyzed the thermal distribution of the induction motor at rated speed operation.

Three Dimensional Simulation Model of Fuel Delivery Jet Pump (연료 송출용 제트펌프 3차원 전산해석 모델)

  • PARK, DAIN;YUN, JIN WON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

A design of the annular induction electromagnetic pump by equivalent circuit modelling (등가회로 해석법에 의한 환단면형 유도전자펌프의 설계)

  • Kim, H.R.;Hong, S.H.;Hwang, J.S.;Min, B.T.;Nam, H.Y.;Cho, M.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1431-1434
    • /
    • 1994
  • The annular induction electromagnetic pump with maximum flowrate of $60{\ell}/min$ for the sodium coolant system of liquid metal fast breeder reacters has been designed using the equivalent circuit method. The final optimum values of geometrical and electromagnetic parameters were obtained for an annular induction pump from the relation of the electrical variables giving the developing force to the fluid and the pressure drops between both sides of the pump. The physical properties of the core, coil condoctor materials in the high temperature and pump cooling systems under operation have been taken into account in the design of the pump. The structural material were also selected considering the reaction with sodium and the magnetic field distortion.

  • PDF

Development of the Automation System for a fish Pump(I) -Adjustable Speed Control of a Fish Pump Using a Simplified PWM Inverter- (피쉬펌프의 자동화 시스템 개발(I) -간이화 PWM 인버터를 이용한 피쉬펌프의 가변속 제어-)

  • 정석권
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.328-334
    • /
    • 1999
  • A fish pump makes very important roles in an automation system of an aquaculture farm, thus it has been used widely in order to transfer fishes from one place to the other place automatically. In spite of its significant roles, the efforts for developing performance and promoting efficiency of the fish pump are not sufficient yet. In this paper, a method which makes the fish pump automation system is suggested. Automation of the fish pump can be accomplished by using variable voltage and variable frequency inverter system including induction motors. Especially, very simple logic to generate Pulse width Modulation(PWM) wave to control induction motor efficiently and three steps speed control method to regulate liquid quantity of the fish pump simply are suggested. Owing to the simplifies speed control and PWM wave generation technique, a cheaper microprocessor, 80C196KC, than a digital signal Processor(DSP) can be used to operate control algorithm in induction motor systems for real time control Also, a new idea of remote control for the simplifies novel inverter system by Programmable logic Controller(PLC) without special output unit, digital to analog converter(D/A), is suggested in this paper. Consequently the function of reliability, availability and serviceability of the fish pump system are developed. It will be expected to contribute expanding of application of the fish pump in aquaculture farms because the system can reduce energy consumption and some difficulties according to manual operation prominently.

  • PDF

A Study on the Design of 34kW Cryogenic Induction Motor for LNG Spray Pump (34kW급 LNG Spray펌프용 극저온 유도전동기 설계에 관한 연구)

  • Jeong, Dong-Wook;Lee, Ki-Wook;Ryu, Jae-Ho;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.918-919
    • /
    • 2015
  • Because of environmental regulations in emissions control area, the demand for ships to use LNG as fuel is increasing. Orders for domestic shipbuilders to produce LNG carriers are steadily increasing. However, major appliances such as spray pump, main cargo pump and others have been relied on imports. Therefore, development of pump motor using at cryogenic temperature is necessary. Operating temperature of an induction motor is at $-163^{\circ}C$. At this low temperature, the resistivity of a motor coil is quite different from normal ones, and so does the torque characteristics of motor. This paper presents a designing method of a cryogenic induction motor for LNG pump. The variation of resistivity of motor coil is considered in the design process. The heat source such as core-loss, hysteresis-loss and copper-loss are analyzed to prevent the LNG evaporation which may cause the motor failure.

  • PDF

Design and Analysis of Electromagnetic Pump Using Linear Induction Motor (선형유도전동기를 이용한 전자기펌프의 설계 및 해석)

  • Kim, Chang-Eob;Jeon, Mun-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.68-73
    • /
    • 2005
  • This paper presents the characteristics analysis of an electromagnetic pump using the linear induction motor(LIM). The electromagnetic pump can be used to transfer the molten metals by the electromagnetic force of LIM. The characteristics of the pump are analyzed solving a hydrodynamic equation with an electromagnetic one.

Electromagnetic Characteristics of MHD Machine (MHD 기기의 전자기적 특성 고찰)

  • Jang, S.M.;Kim, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.266-268
    • /
    • 1998
  • The linear MHD(magnetohydro-dynamic) machine obtains the linear motion by replacing the solid conducting secondary of LIM with the ionized gas, plasma or the liquid metal. The electromagnetic pump which is a kind of MHD machine is divided into induction pump and conduction pump. This paper shows the classification and development trends of MHD machines and the characteristics of double sided flat linear induction pump (DFLIP).

  • PDF

Study on the Generating Operations of the Induction Motor for Driving the Pump During Instantaneous Power Interruption (순간 정전시 펌프 구동용 유도전동기의 발전 동작에 관한 연구)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.65-70
    • /
    • 2016
  • Power interruption is a phenomenon that no voltage is displayed over a short time or long time. Most devices will not operate normally when the supply voltage is low or does not exist. However, the device can also be operated with a different power which is ensured by a separate power generation. Recently, power interruption has been reduced gradually by the improvement of electricity quality, its duration also has been very short. Induction motors are widely used for the pumping in the water and sewage facilities and power plant applications. The pump is used as a machine for moving the fluid in the high place from a low location. So pump equipment always have a potential energy. If a momentary interruption occurs, the potential energy of the pump is reversed as that of water turbine and motor is operated as generator. This study is an analysis for the voltage variation, current, torque and power flow by the generating operation of the induction motor before and after the change of momentary interruption.

Development of Computer Program for Design of the Small Annular Linear Induction EM Pump (소형 환단면 선형유도전자펌프 설계를 위한 전산 프로그램 개발)

  • Kim, H.R.;Nam, H.Y.;Hwang, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.137-140
    • /
    • 2002
  • EM(ElectroMagnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study, computer program for the pilot annular linear EM pump has been developed for the maximum flowrate with 200 l/min and maximum developing pressure with 3 bar. Firstly, Balance equation is induced by the equivalent circuit method which is commonly employed to analyze linear induction machines and the calculation of the hydraulic pressure drop. Then, design equation is converted to the computer program and optimum pump variables are determined by this code. The code is verified by the comparative analysis with the characteristic of the commercialized pump.

  • PDF