• Title/Summary/Keyword: Induced variation

Search Result 1,066, Processing Time 0.034 seconds

Modeling and Verification for Stability Analysis of Axially Oscillating Cantilever Beams (축 방향 왕복운동을 하는 외팔보의 안정성 해석을 위한 모델링 및 검증)

  • Kim, Sung-Do;Yoo, Hong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.708-713
    • /
    • 2005
  • Modeling and verification for stability analysis of axially oscillating cantilever beams are investigated in this paper. Equations of motion for the axially oscillating beams are derived and transformed into dimensionless forms. The equations include harmonically oscillating parameters which are related to the motion-induced stiffness variation. Stability diagram is obtained by using the multiple scale perturbation method. To verify the accuracy of the modeling method, several points in the plane of the stability diagram are presented and solved. The present modeling method proves to be as accurate as a nonlinear finite element modeling method.

  • PDF

Evaluation of Factors Affecting Glomerular Filtration Rate by Contrast Media in Patients with Coronary Angiography (심혈관 조영술 시행 환자의 조영제 사용 시 사구체여과율 변화에 영향을 미치는 인자들 평가)

  • Kim, Eun-Young;Lee, Ok-Sang;Lim, Sung-Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.103-112
    • /
    • 2012
  • Performance of coronary angiography for exact diagnosis and treatments of cardiovascular disease have been increased recently and it also brings increase of the contrast-induced nephropathy (CIN) referred from increasing use of radiological contrast agents. The variation of estimated glomerular filtration rate (eGFR) is an indicator of CIN, which is known to increase when renal function is decreased. Therefore, this study was to evaluate the affecting factors including concomitant drug on variation of eGFR of patients who underwent coronary angiography according to the conditions of renal function. Medical records of 66 patients were evaluated retrospectively and the patients underwent coronary angiography or angioplasty with nonionic and isotonic contrast media (iodixanol) at Chungnam national university hospital from 1 Jan 2008 to 30 Jul 2010. Patients group was divided into 2 groups; the patients in stages 3-4 chronic kidney disease (CKD) and the patients in stage 2 CKD. Each group was researched about the effect of concomitant drug and clinical characteristics on eGFR variation. The change of eGFR was compared among baseline and 2 or 3 day after coronary angiography. In results, the eGFR variation in group over age 75 was significantly decreased after radiological contrast agents exposure (p $$\leq_-$$ 0.05). The eGFR variation in anemia was significantly decreased after radiological contrast agents exposure in stage 2 CKD (p > 0.05). The eGFR variation in group under $HbA_{1c}$ 6.5% was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, angiotensin converting enzyme inhibitors, calcium channel blockers and nitroglycerin was increased after radiological contrast agents exposure in stage 2 CKD (p $$\leq_-$$ 0.05). The eGFR variation by using of diuretics was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, nitroglylcerin was increased after radiological contrast agents exposure in stages 3-4 CKD(p > 0.05). The eGFR variation in group over contrast dosage 150 ml was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). Therefore, when undergoing coronary angiography, contrast dosage should be minimized less than 150 ml, and diuretics should be restricted as possible in stages 3-4 CKD. Patients over age 75 require special attention to prevent CIN, and if patients undergo coronary angiography in stages 3-4 CKD, $HbA_{1c}$ is also requried to maintain below 6.5% to prevent CIN.

Measurement of Qi Induced by the Needle Insertion on LI4, LI11 Accupoint using the Oriental Medicine Instruments (인체(人體)의 합곡(合谷) 곡지(曲池) 침자(鍼刺)에 관한 한방진단기기적(韓方診斷機器的) 접근(接近))

  • Jang, K.S.;Na, C.S.;So, C.H.
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.159-178
    • /
    • 1995
  • After acupuncture needles were inserted on apkok(LI4) and Kokchi(LI11) accupoints, physiological changes induced by the varitions of 'Qi' were measured. The body temperature and pulse frequency were fromed to be decreased observed and we presumed that the needle insertion induced some changes of Qi in meridian and this seemed to be achieved by a certain process of Qi induction. We applied EAV, nervinemeter and pulse-taking machine which is widely used as oriental medicine instruments, to the same vounteers and observed the significant variations for each apparatus in spite of partial lack of reproducibility. In this paper, we described about the physical quantity measured by the medical appartatus and how it was related to the variation of Qi The proper conditions used for good oriental medicine instruments have also been suggested.

  • PDF

Behavioral Adaptation to an Adaptive Cruise Control System (적응순항제어시스템의 운전자 행동적응)

  • Lee, Woon-Sung;Kim, Young-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.82-88
    • /
    • 2006
  • The study investigated how an adaptive cruise control system induced behavioral adaptation in drivers using a full-scale driving simulator. Forty drivers with different driving styles participated in the study to compare headway-time, vehicle lateral position variation, and head and eye movement when driving with and without the adaptive cruise control system. Results showed that system induced positive behavioral adaptation by drawing consistency in driving speed and headway-time regardless of the driving styles. However, the results also showed that the drivers' reliance on the system induced negative adaptation including reduced lane keeping ability and reduced attention during driving. As a strategy to prevent negative adaptation, the study proposed information service to drivers with the adaptive cruise control system status and driving environment, and investigated effectiveness of the service. Twelve drivers participated in the experiment to compare headway-time, vehicle lateral position variation and subjective ratings when driving with and without the information service. Results showed that the information service assisted the drivers to maintain safer and more comfortable headway-time without impairing drivers' steering ability.

Pressure Fluctuation Induced by Propeller Sheet Cavitation with Consideration of the Near Field Effect (근접장 효과를 고려한 추진기 얇은 층 캐비테이션에 의해 유기되는 변동압력에 관한 연구)

  • Seol, Han-Shin;Moon, Il-Sung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.2
    • /
    • pp.105-113
    • /
    • 2009
  • A theoretical study on the pressure fluctuation induced by a propeller was carried out in this study. The main objective of this study is to analyze the source mechanism of the pressure fluctuation induced by propeller sheet cavitation. To analyze the pressure fluctuation induced by propeller sheet cavitation, modern acoustic theory was applied. Governing equation of pressure fluctuation induced by sheet cavitation was derived using Ffowcs Williams proposed time domain acoustic approaches. Several factors affecting pressure fluctuation were analyzed based on the derived governing equation. Pressure fluctuation result was represented by combined results of the far field term and near field term. Finally, the physical mechanism of pressure fluctuation at the blade rate frequency was analyzed using numerically generated cavitation volume variation.

A Numerical Study on the Source Mechanism of the Pressure Fluctuation Induced by Propeller Cavitation

  • Seol, Han-Shin;Moon, Il-Sung
    • Journal of Ship and Ocean Technology
    • /
    • v.12 no.2
    • /
    • pp.32-40
    • /
    • 2008
  • This paper deals with the pressure fluctuation induced by propeller cavitation. The main objective of this study is to analyze the source mechanism of the pressure fluctuation induced by propeller cavitation. To analyze the source mechanism of the pressure fluctuation, modem acoustic theory is applied. The governing equation of the pressure fluctuation induced by propeller is derived using Ffowcs Williams-Hawkings proposed time domain acoustic method. The physical mechanism of pressure fluctuation at the blade rate frequency is analyzed using numerically generated cavitation volume variation. Finally the characteristics of the pressure fluctuation induced by a propeller are presented.

Bridge modal identification based on frequency variation caused by a parked vehicle

  • He, Wen-Yu;Ren, Wei-Xin;Wang, Quan;Wang, Zuo-Cai
    • Structural Engineering and Mechanics
    • /
    • v.84 no.3
    • /
    • pp.413-421
    • /
    • 2022
  • Modal parameters are the main dynamic characteristics of bridge. This study aims to propose an innovative route to estimate the modal parameters for bridges by using a parked vehicle in which mode shapes with high accuracy and spatial resolution are identified by frequency measurement. Based on the theory of dynamic modification and modal identification, the mathematical formulation between the parked mass induced frequency variation and the modal parameters of a bridge is derived. Then this mathematical formulation is extended to a parked vehicle-bridge system. The arithmetic and processes for estimating the modal parameters based on the identified frequency variation of the vehicle-bridge systems when the vehicle locates at sequentially arranged positions are presented. Finally the proposed method is applied to several simulated bridges of different types. The results indicate that it can estimate the modal parameters with high accuracy and efficiency.