• Title/Summary/Keyword: Induced angle

Search Result 784, Processing Time 0.027 seconds

Scenario Analysis of Injection Temperature and Injection Rate for Assessing the Geomechanical Stability of CCS (Carbon Capture and Sequestration) System (이산화탄소 격리저장시스템의 역학적 안정성 평가를 위한 주입온도 및 주입량 시나리오 해석)

  • Kim, A-Ram;Kim, Hyung-Mok
    • Tunnel and Underground Space
    • /
    • v.26 no.1
    • /
    • pp.12-23
    • /
    • 2016
  • For a successful accomplishment of Carbon Capture Sequestration (CCS) projects, appropriate injection conditions should be designed and optimized for site specific geological conditions. In this study, we evaluated the effect of injection conditions such as injection temperature and injection rate on the geomechanical stability of CCS system in terms of TOUGH-FLAC simulator, which is one of the well-known T-H-M coupled analysis methods. The stability of the storage system was assessed by a shear slip potential of the pre-existing fractures both in a reservoir and caprock, expressed by mobilized friction angle and Mohr stress circle. We demonstrated that no tensile fracturing was induced even in the cold CO2 injection, where the injected CO2 temperature is much lower than that of the reservoir and tensile thermal stress is generated, but shear slip of the fractures in the reservoir may occur. We also conducted a scenario analysis by varying injected CO2 volume per unit time, and found out that it was when the injection rate was decreasing in a step-wise that showed the least potential of a shear slip.

Effects of Needle Response on Spray Characteristics In High Pressure Injector Driven by Piezo Actuator for Common-Rail Injection System

  • Lee Jin Wook;Min Kyoung Doug
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1194-1205
    • /
    • 2005
  • The common-rail injection systems, as a new diesel injection system for passenger car, have more degrees of freedom in controlling both the injection timing and injection rate with the high pressure. In this study, a piezo-driven injector was applied to a high pressure common-rail type fuel injection system for the control capability of the high pressure injector's needle and firstly examined the piezo-electric characteristics of a piezo-driven injector. Also in order to analyze the effect of injector's needle response driven by different driving method on the injection, we investigated the diesel spray characteristics in a constant volume chamber pressurized by nitrogen gas for two injectors, a solenoid-driven injector and a piezo-driven injector, both equipped with the same injection nozzle with sac type and 5-injection hole. The experimental method for spray visualization was based on back-light photography technique by utilizing a high speed framing camera. The macroscopic spray propagation was geometrically measured and characterized in term of the spray tip penetration, spray cone angle and spray tip speed. For the evaluation of the needle response of the above two injectors, we indirectly estimated the needle's behavior with an accelerometer and injection rate measurement employing Bosch's method was conducted. The experimental results show that the spray tip penetrations of piezo­driven injector were longer, on the whole, than that of the solenoid-driven injector. Besides we found that the piezo-driven injector have a higher injection flow rate by a fast needle response and it was possible to control the injection rate slope in piezo-driven injector by altering the induced current.

The Effects of Skeletal Muscle Mass and Muscle Fatigue on the Proprioceptive Position Sense of the Knee Joint (뼈대근육량과 근피로가 무릎관절 고유수용성 위치감각에 미치는 영향)

  • Park, Sookyoung;Park, Kanghui
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.2
    • /
    • pp.139-147
    • /
    • 2020
  • Purpose : Proprioceptive position sense plays a key role in providing joint stability, and multiple factors are related to proprioceptive position sense. Thus, this study aimed to determine the effects of body composition, particularly skeletal muscle mass on proprioceptive position sense following muscle fatigue. Methods : Healthy female subjects agreed to have their body composition analyzed. Only subjects who had 18.5-22.9 kg/㎡ of BMI (body mass index) were included in this study, and the participants were divided into two groups by skeletal muscle mass level. The experimental group had a level of skeletal muscle lower than the standard level (n=9), while the control group showed a standard or high level of skeletal muscle mass (n=11). To determine the change in proprioceptive position sense of the knee joint, the absolute angle error (AAE) was evaluated following muscle fatigue on low extremity. The muscle fatigue was induced by isokinetic resistance exercise program of Biodex system. AAE was measured by the Biodex system and compared the result before and after muscle fatigue. Results : The experimental group showed a significant AAE difference between before (3.16±2.48 °) and after (5.40±2.61 °) muscle fatigue. In addition, there was a AAE difference between the experimental (5.40±2.61 °) and control groups (3.53±1.67 °) after fatigue; however, there was no significance. Those results indicated that low level of skeletal muscle mass might influence the proprioceptive position sense of the knee joint after muscle fatigue. Conclusion : Thus, maintaining the proper level of skeletal muscle mass is pivotal to reduce the risk of injury following muscle fatigue in ADL or sport activities.

Geometric Regualrization of Irregular Building Polygons: A Comparative Study

  • Sohn, Gun-Ho;Jwa, Yoon-Seok;Tao, Vincent;Cho, Woo-Sug
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.6_1
    • /
    • pp.545-555
    • /
    • 2007
  • 3D buildings are the most prominent feature comprising urban scene. A few of mega-cities in the globe are virtually reconstructed in photo-realistic 3D models, which becomes accessible by the public through the state-of-the-art online mapping services. A lot of research efforts have been made to develop automatic reconstruction technique of large-scale 3D building models from remotely sensed data. However, existing methods still produce irregular building polygons due to errors induced partly by uncalibrated sensor system, scene complexity and partly inappropriate sensor resolution to observed object scales. Thus, a geometric regularization technique is urgently required to rectify such irregular building polygons that are quickly captured from low sensory data. This paper aims to develop a new method for regularizing noise building outlines extracted from airborne LiDAR data, and to evaluate its performance in comparison with existing methods. These include Douglas-Peucker's polyline simplication, total least-squared adjustment, model hypothesis-verification, and rule-based rectification. Based on Minimum Description Length (MDL) principal, a new objective function, Geometric Minimum Description Length (GMDL), to regularize geometric noises is introduced to enhance the repetition of identical line directionality, regular angle transition and to minimize the number of vertices used. After generating hypothetical regularized models, a global optimum of the geometric regularity is achieved by verifying the entire solution space. A comparative evaluation of the proposed geometric regulator is conducted using both simulated and real building vectors with various levels of noise. The results show that the GMDL outperforms the selected existing algorithms at the most of noise levels.

STRUCTURAL PERTURBATIONS INDUCED BY PHOTODYNAMIC ACTION OF PORPHYRIN AGGREGATES ON PLASMA MEMBRANE AND MICROSOMES OF GLIOBLASTOMA CELLS

  • Sreentvasan, Rajesh;Joshi, Preeti G.;Joshi, Nanda B.
    • Journal of Photoscience
    • /
    • v.4 no.2
    • /
    • pp.41-48
    • /
    • 1997
  • The plasma membrane and microsomes, isolated from the cells treated with hematoporphyrm derivative (HpD) for 1 and 24 h, accumulated the aggregated porphyrin. The quantity of aggregated porphyrin was same in the plasma membrane and microsomes after isolating them from cells treated with HpD for 1 h whereas the microsomes accumulated higher quantity of aggregated porphyrin when cells were treated with HpD for 24 h. Photodynamic action of aggregated porphyrin on plasma membrane and microsomes was investigated using lipid specific fluorescent probes: 1,6-diphenyl-1,3,5-hexatrine (DPH) and 1-(4-trimethylammonium), 6-diphenyl-1,3,5-hexatrine(TMA-DPH). The time dependent anisotropy of these probes in the membranes was measured and the decay of anisotropy was analyzed using wobbling in cone model. Upon irradiation both the plasma membrane and the microsomes showed an increase in the limiting anis~)tropy and order parameter and a decrease in the cone angle of the lipid probes. The increase in the limiting anisotropy was pronounced in membranes isolated from the cells treated with HpD for 24 h. Photoinduced change in the limiting anisotropy was dependent on the duration of incubation of cells with HpD before isolating the membranes. In both the membranes. the membrane core was affected more as compared to the outer leaflet. In addition to the structural changes, a decrease in Na$^+$-K$^+$-ATPase and NADPH cyt c reductase activity was also observed upon irradiation of HpD treated cells. Inhibition in NADPH cyt c reductase was more when cells were treated with HpD for 24 h, however, Na$^+$-K$^+$-ATPase activity did not depend on the duration of the treatment of cells with HpD before irradiation. Our results suggest that the extent of photoinduced perturbations in the membranes varies as a function of duration of the treatment of cells with HpD and the membrane core is more susceptible to the photodynamic action of aggregated porphyrin.

  • PDF

Kinematic Comparisons of Kettlebell Two-Arm Swings by Skill Level

  • Back, Chang-Yei;Joo, Ji-Yong;Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.39-50
    • /
    • 2016
  • Objective: The purposes of this study were to compare the kinematics of a two-arm kettlebell swing between experts and beginners and to identify the correct postures and biomechanical key points in an attempt to prevent sports injuries induced by a kettlebell swing. Methods: Four experts (height, $169.7{\pm}1.5cm$; weight, $70.5{\pm}1.8kg$; age, $32.0{\pm}1.0years$) licensed to teach kettlebell exercises and three beginners (height, $173.7{\pm}4.1cm$; weight, $78.3{\pm}3.8kg$; age, $30.0{\pm}1.4years$) with no kettlebell exercise experience participated in this study. Each participant performed 15 repetitions of a two-arm kettlebell swing using a 16-kg weight. Joint angles, angular velocities, and peak angular velocity sequences were calculated and compared between the two groups. Results: Large ranges of motion (ROM) of the pelvic angle and hip joints were detected in the experts, while beginners showed greater ROM of the shoulder joint. Peak angular velocity magnitudes and sequences were significantly different between the two groups. Experts lifted the kettlebell upward using the hip joints, pelvis, and shoulder joints (proximal to distal order) sequentially and lowered it using the reverse order of peak angular velocities from the shoulder to hip joints. Conclusion: Mobility of the pelvic segment and hip joint are required, while stability of the other joints is needed to produce appropriate two-arm kettlebell swings. The activation and coordination of the gluteal and hamstring muscles are key points in kettlebell exercises.

Emission and Structural Properties of Titanium Oxide Nanoparticles-coated a-plane (11-20) GaN by Spin Coating Method

  • Kim, Ji-Hoon;Son, Ji-Su;Baik, Kwang-Hyeon;Park, Jung-Ho;Hwang, Sung-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.146-146
    • /
    • 2011
  • The blue light emitting diode (LED) structure based on non-polar a-plane (11-20) GaN which was coated TiO2 nanoparticles using spin coating method was grown on r-plane (1-102) sapphire substrates to improve light extraction efficiency. We report on the emission and structural properties with temperature dependence of photoluminescence (PL) and x-ray rocking curves (XRC). From PL results at 13 K of undoped GaN samples, basal plane stacking fault (BSF) and near band edge (NBE) emission peak were observed at 3.434 eV and 3.484 eV, respectively. We also found the temperature-induced band-gap shrinkage, which was fitted well with empirical Varshini's equation. The PL intensity of TiO2 nanoparticles ?coated multiple quantum well (MQW) sample is decayed slower than that of no coating sample with increasing temperature. The anisotrophic strain and azimuth angle dependence in the films were shown from XRC results. The full width at half maximum (FWHM) along the GaN [11-20] and [1-100] directions were 564.9 arcsec and 490.8 arcsec, respectively. A small deviation of FWHM values at in-plane direction is attributed to uniform in-plane strain.

  • PDF

Influence of Depth Differences by Setting 3D Stereoscopic Convergence Point on Presence, Display Perception, and Negative Experiences (스테레오 영상의 깊이감에 따른 프레즌스, 지각된 특성, 부정적 경험의 차이)

  • Lee, SangWook;Chung, Donghun
    • Journal of Broadcast Engineering
    • /
    • v.19 no.1
    • /
    • pp.44-55
    • /
    • 2014
  • The goal of 3D stereoscopy is not only to maximize positive experiences (such as sense of realism) by adding depth information to 2D video but to also minimize negative experiences (such as fatigue). This study examines the impact of different depth levels induced by adjusting 3D camera convergences on positive and negative experiences and finds an optimal parameter for viewers. The results show that there are significant differences among depth levels on spatial involvement, realistic immersion, presence, depth perception, screen transmission, materiality, shape perception, spatial extension and display perception. There are also significant differences for fatigue and unnaturalness. This study suggests that reducing the camera convergence angle of an object by $0.17^{\circ}$ behind the object is the optimal parameter in a 3D stereoscopic setting.

SURFACE ANALYSES OF TITANIUM SUBSTRATE MODIFIED BY ANODIZATION AND NANOSCALE Ca-P DEPOSITION

  • Lee, Joung-Min;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.795-804
    • /
    • 2007
  • Statement of problem. Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known about their surface characteristics that have influence on tissue-implant interaction. Purpose. This study was aimed to investigate microtopography, surface roughness, surface composition, and wettability of the titanium surface modified by the anodic oxidation and calcium phosphate coating using IBAD. Material and methods. Commercially pure titanium disks were used as substrates. The experiment was composed of four groups. Group MA surfaces represented machined surface. Group AN was anodized surface. Group CaP/AN was anodic oxidized and calcium phosphate coated surfaces. Group SLA surfaces were sandblasted and acid etched surfaces. The prepared titanium discs were examined as follows. The surface morphology of the discs was examined using SEM. The surface roughness was measured by a confocal laser scanning microscope. Phase components were analyzed using thin-film x-ray diffraction. Wettability analyses were performed by contact angle measurement with distilled water, formamide, bromonaphtalene and surface free energy calculation. Results. (1) The four groups showed specific microtopography respectively. Anodized and calcium phosphate coated specimens showed multiple micropores and tiny homogeneously distributed crystalline particles. (2) The order of surface roughness values were, from the lowest to the highest, machined group, anodized group, anodized and calcium phosphate deposited group, and sandblasted and acid etched group. (3) Anodized and calcium phosphate deposited group was found to have titanium and titanium anatase oxides and exhibited calcium phosphorous crystalline structures. (4) Surface wettability was increased in the order of calcium phosphate deposited group, machined group, anodized group, sandblasted and acid etched group. Conclusion. After ion beam-assisted deposition on anodized titanium, the microporous structure remained on the surface and many small calcium phosphorous crystals were formed on the porous surface. Nanoscale calcium phosphorous deposition induced roughness on the microporous surface but hydrophobicity was increased.

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.