• Title/Summary/Keyword: Induced air

Search Result 1,074, Processing Time 0.031 seconds

Development of a Low Noisy Type of Air-line Mask (저소음형 송기마스크 개발)

  • Paik, Eun-Gyu;Kim, Bong-Nyun;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.277-281
    • /
    • 2005
  • Air-line mask is an important personal protective equipment for workers working under hazardous surroundings in which a fixed ventilation system is difficult to be installed. If the air-line mask make loud noise, works wearing the mask may be faced with health problems such as noise induced hearing loss(NIHL). The purpose of this study is to introduce a low noisy technology for workers using air-line mask. A traditional type air-line has been improved to an advanced air-line mask with lesser noise. In the mask, air suppling conduits consists of multi tubes are placed inside of the front of the safety helmet. The noise level reduced from 80dB(A) to less than 80dB(A) when measured by KS A 0701 method at Center for Safety Inspection, Testing and Certification for KOSHA. It is suitable for related regulation[Article 35 of the Industrial Safety and Health Act(Test of Personal Protective Equipment)]. While workers working in noise level of over 90dB(A), they may expose to 82dB(A) or less when they wear the advanced masks. This type masks can be an alternative for works suffering from loud noise generated by traditional air-line masks.

CFD Analysis on the Internal Air Flow Control in a Wax Spin Coater of Silicon Wafer Polishing Station (실리콘 웨이퍼 연마장비용 왁스 스핀코팅장치의 내부기류 제어에 관한 전산유동해석)

  • Kim, Kyoung-Jin;Kim, Dong-Joo;Park, Joong-Youn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, the air flow induced by the rotating flat disk is numerically investigated in a hope to better understand the air flow structures inside the wax spin coater for a silicon wafer polishing station. Due to the complex inner geometry of actual spin coater such as the casing around the rotating ceramic block and servo motor, recirculation of air flow is inevitably found on the coating target if the internal space of spin coater is closed at the bottom and it could be the possible source of contamination on the wax coating. By numerical flow simulation, we found that it is necessary to install the air vent at the bottom and to apply the sufficient air suction in order to control the path of air flow and to eliminate the air recirculation zone above the spinning surface of coating target.

Analysis on the flux density in Air-Cored and Iron-Cored type Syschrous Macl (공심형 및 철심형 동기기의 특성해석)

  • Jang, S.M.;Cho, S.K.;Yoon, I.K.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.604-606
    • /
    • 2002
  • Air-cored machines have a higher efficiency with high frequency. speed than iron-cored machine because of the iron losses which may produce too much heat as well as the copper losses occurred in the rotor winding. But air-cored machine is lower flux than iron machine. The nature of the machine from 'iron-cored' to 'air-cored' is a progressive feature in the machines. A general analysis of the fields that is applicable to all configurations is presented. Slotless machines have been applied for no ripple induced voltage. In this paper, slotless mahcines equipped with internal 4-pole amature winding. This paper pay attention to analyze flux density of air-cored and iron-cored synchrous machine analytically and compare flux density of aired-cored machine to iron-cored machine.

  • PDF

Study on the Indoor Air Purification Technology by Using Nonthermal Plasma (비열 방전 플라즈마에 의한 실내 공기 청정기술 연구)

  • Jung, Jae-Seung;Lee, Heon-Gyeong;Kim, Jin-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.31-36
    • /
    • 2016
  • For the purpose of indoor air purification, air conditioner or purifier is generally used, but the long operating time induced the contamination by cumulation of bacteria in the air filter. The ozone sterilization method can be one of the effective sterilization method for this case. Ozone has not leave a secondary residual contaminants, as well as a strong sterilization power. In this study, nonthermal plasma technology is investigated as an ozone generator for the air filter sterilization. Additionally, nonthermal plasma technology is possible to obtain the generation of negative ions and electrostatic force by simply adjusting the applied voltage.

Reduction of NOx Emissions in Turbulent Hydrogen Diffusion Flame using Acoustic Excitation (음파가진에 의한 동축공기 수소 확산화염의 NOx 배출저감연구)

  • Kim, Mun-Ki;Han, Jeong-Jae;Yoon, Sang-Wook;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2005
  • Measurements of flame length and NOx emissions have been conducted to investigate the effects of acoustic excitation on flame structure in turbulent hydrogen diffusion flames with coaxial air. When the acoustic excitation of a specific frequency is applied to coaxial air stream, flame length is dramatically reduced, resulting in reduction of flame residence time. Consequently, EINOx could decrease up to 35 % and this shows that acoustic excitation is effective in reducing NOx emissions. Mie scattering technique has been used to visualize the vortex structure induced by acoustic excitation and vortex formation, development and destruction were observed quantitatively. As a result, vortex entrains coflow air into fuel stream and mixing rate between fuel and air is significantly enhanced, which may contribute to reduction of NOx emissions.

  • PDF

A Study on the Measurement Error Induced by Air Gap of Electromagnetic Wave Absorber in the Coaxial Line Method (동축선법을 이용한 전파흡수체 특성 측정시 Air Gap에 의한 오차에 대한 연구)

  • 김경용;김왕섭;주윤돈;김병호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.874-879
    • /
    • 1991
  • The effect of air gap between specimen and jig on the material constant (permittivity, permeability) and attenuation characteristics of electromagnetic wave absorbers in the coaxial line method was investigated. The presence of a air gap made both permittivity and permeability measured lower than true value, and the tendency was greater in the case of permittivity. An inner gap compared to an outer gop was found to yield a larger difference between measured and true values. The effect of air gap was measured for a Ni0.3Zn0.7Fe2O4, with the gap eliminated by metallizing with Ag-paste. The measured characteristics were in good agreement with corrected values by calculation.

  • PDF

A Study on Noise Identification of Indoor Air-conditioner Using Experimental Methods (실험적 방법을 통한 에어컨 실내기의 소음원 검출에 관한 연구)

  • 이성진;오재응;이정윤;강태호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.87-87
    • /
    • 2004
  • An air-conditioner has various noise sources such as a fan noise, a motor noise, and a vibration induced noise. To reduce these noise effectively, noise sources must be identified. Especially in this paper, the structure borne sound radiated from the motor bracket of the indoor air-conditioner is considered. To do this, the operational deflection shape, which is used for understanding of the behavior of the motor bracket at a particular frequency, is obtained and compared with the sound intensity, which is used for the noise identification. Through this study, the noise sources of indoor air-conditioner are defined and the effective noise reduction method is proposed.

  • PDF

Pneumocephalus Developed during Epidural Anesthesia for Combined Spinal-Epidural Anesthesia (척추경막외병용마취를 위한 경막외마취 중 발생한 기뇌증)

  • Kim, Youn Jin;Baik, Hee Jung;Kim, Jong Hak;Jun, Joo Hyun
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.163-166
    • /
    • 2009
  • The superiority of air versus saline for identifying the epidural space remains unestablished. Epidural anesthesia using a loss of resistance technique (LORT) with air is associated with increasing complications of dural puncture-induced headaches and neurological and hemodynamic changes. Here, we described a case of pneumocephalus with a large amount of air that was accompanied by severe headache and nuchal and chest pain occurring after epidural block using LORT with air for combined spinal-epidural anesthesia.

Vibration Characteristics of CD and DVD Disks (CD 및 DVD 디스크의 진동 특성)

  • 이승엽;임효석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.998-1003
    • /
    • 2003
  • The aerodynamically excited vibration and natural frequency of rotating CD and DVD disks are analytically and experimentally studied in this paper The theoretical analysis uses a fluid-structure model where the aerodynamic effects are represented in terms of elastic, lift and damping components. The explicit expression on natural frequency of the air coupled disk is obtained as functions of the three aerodynamic coefficients. The experiments performed using a vacuum chamber and CD/DVD disks rotating in vacuum, open air and enclosure give three main results. One is that the aerodynamic effect by the surrounding air reduces the natural frequencies and critical speeds of the vibration modes. The second is that natural frequency of disks rotating in open air is larger than that in enclosure. Finally, it is shown that the disk vibration is reduced as the gap between the disk and the rigid wall decreases.

  • PDF

Relationship between Thermal Low and Long-Range Transport of Air Pollutants (대기오염물질의 장거리 수송과 열적저기압의 관계)

  • 이화운;김유근;김해동;정우식;현명숙
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • The atmospheric conditions and the transport mechanism of long-range transport of air pollutants from coastal area to inland area were investigated using regular meteorological data and air pollution data obtatined from the southeastern area of Korea. Daytime temperature over the inland area(Taegu) was higher than that over the coastal area(Pusan) and the temperature difference of about 5~6$^{\circ}C$ when the thermal low most fully developed and the sea level pressure over Taegu was lower than that over Pusan by about 4~5hPa at that time. Therefore this low pressure appeared to the thermally induced low. Air mass polluted from the coastal area during the morning period was transported inland area, at first by the sea breeze and by the large scale wind system toward the thermal low generated in the mountainous inland region. This was explained by the fact that the concentration of air pollutants over Taegu increased throughtout the late afternoon.

  • PDF