• 제목/요약/키워드: Induced air

검색결과 1,070건 처리시간 0.025초

유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석 (Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map)

  • 한형석;모진용;정의봉
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

Reduction of the Refrigerant-Induced Noise from the Transition of Flow Pattern by Decreasing Tube Diameter

  • Takushima, Akira;Han, Hyung-Suk;Jung, Wei-Bong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권2호
    • /
    • pp.37-44
    • /
    • 2009
  • It is well known that a refrigerant-induced noise is caused by two-phase flow in the indoor unit of a heat pump air-conditioner. Especially when the flow pattern in a pipe is intermittent flow, the irregular noise occurs frequently. But it is very difficult to avoid this kind of the noise for the application of air-conditioner. Therefore, in this research, the flow patterns at two-phase flow state in a pipe of the indoor unit for the air-conditioner are researched using cycle simulator at typical cycle conditions. In order to find the relationship between refrigerant-induced noise and flow pattern, the noise patterns are investigated with respect to the estimated flow pattern from the various flow pattern maps. Base on the estimations of the flow patterns by those maps, the refrigerant-induced noise is evaluated as decreasing tube diameter, which can transit the flow pattern from slug to annular flow.

지하철 터널내 운행열차에 의한 열차풍의 산정 (Estimation of Train-Induced Wind Generated by Train Operation in Subway Tunnels)

  • 김신도;송지한;이희관
    • 설비공학논문집
    • /
    • 제16권7호
    • /
    • pp.652-657
    • /
    • 2004
  • Development of underground space in urban area has a huge amount of potential to ease the limitations on the land use and the efficiency especially in urban area. Considering public transportation in urban area, subway system could be one of the most efficient and practical approaches. Subsequently this leads the public to have more chances to experience the indoor air quality (IAQ) in subway systems. In this study, it was aimed to produce useful data for the IAQ control in subway environments, Specifically the train-induced wind has been investigated by means of field survey and analysis. The recent updates including the quantified characteristics of train-induced wind are presented in this paper.

Mouse Air Pouch Model에서 침전극 저주파치료로 유도된 소염 작용에 관한 연구 (Study for Related Mechanism of Anti-Inflammatory Effect Induced by Neddle electrode electrical stimulation in Mouse Air Pouch Model.)

  • 정진우;황현숙;임종수
    • 대한물리치료과학회지
    • /
    • 제9권2호
    • /
    • pp.111-122
    • /
    • 2002
  • In oriental medicine, manual-acupuncture and electroacupuncture (EA) have been widely utilized to cure several inflammatory diseases such as arthritis. We designed this experiment to find neurochemical mechanism related to electroacupuncture induced anti-inflammatory effect on mouse air pouch model. EA with both low frequency (1 Hz) and high frequency (120 Hz) was treated after induction of inflammation in air pouch using injection of zymosan. To verify the role of opioid system in electroacupuncture-induced anti-inflammatory effect, naloxone (10 mg/kg) was pretreated. In addition, idazoxan (5 mg/kg) was pre-treated to evaluate the possible effect of endogenous adrenergic system in autonomic system on EA induced anti-inflammatory effect. As results of this study, naloxone pretreatment did not change the anti-inflammatory effect evoked by high frequency EA, while low frequency EA(1 Hz) induced anti-inflammatory effect was dramatically suppressed by naloxone pretreatment. These data indicated that endogenous opioid system might be extensively involve in anti-inflammatory effect evoked by not high frequency, but low frequency EA. However, idazoxan pretreatment did not produce any modulatory effect on both low and high frequency EA induced anti-inflammatory effect, suggesting that EA induced anti-inflammatory effect was not mediated by endogenous adrenergic system. In conclusion, these data strongly suggested that EA induced anti-inflammatory effect is mediated by endogenous opioid system, not endogenous adrenergic system.

  • PDF

Metal Effects of Urban Air Particulates on Cytokine Production and DNA Damage

  • Lee, Kwan-Hee;Hong, Yun-Chul
    • Toxicological Research
    • /
    • 제17권4호
    • /
    • pp.255-265
    • /
    • 2001
  • Epidemiologic studies have demonstrated an association between short-term exposure to particulate air pollutants and increased mortality. However the biological mechanism underlying these associations have not been fully established and also the chemical and physical characteristics of the pollutant particles are not well understood. The metal constituents of air pollutant particles and their bioavailability are considered to Play an important role as possible mediators of Particle-induced airway injury and inflammation. Sprague-Dawley rat alveolar macrophage cells (NR8383) were exposed to airborne and acid-leached particulate matter (PM). Titanium oxide and nickel subsulfide were used as negative and positive controls. Particle-induced reactive oxygen species formation in cells was detected using the fluorescent probe 2',7'-dichlorofluorescin diacetate. Expression of TNF-$\alpha$ and IL-6 were measured by enzyme-linked immunosorbent assay, and PM-induced DNA double-strand breaks were determined with $\lambda$DNA/Hind III marker. Metals associated with air pollutant particles mediated intracellular oxidant production in alveolar macrophages, and the cytotoxicity and proinflammatory cytokine production induced by PM were associated with oxidative stress. The oxidants produced by air pollutant particles also are likely to induce DNA double-strand breaks. Our findings in alveolar macrophage cells exposed to PM and acid-leached PM support the hypothesis that metal components in urban air pollutants and their bioavailabilities might play an Important role in the induction of the adverse health effects.

  • PDF

아세톤 형광을 이용한 공연비 측정 기법 연구 (An Experimental Investigation of Air Fuel Ratio Measurement using Laser Induced Acetone Fluorescence)

  • 박승재;허환일;오승묵
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.353-356
    • /
    • 2002
  • Planar laser induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Preliminary investigation was performed to measure quantitative air excess ratio distribution in an engine fueled with LPG. It is known that fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone was excited by KrF excimer laser (248nm) and its fluorescence image was acquired by ICCD camera with a cut-of filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile was suggested. Raw images were divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which was taken by a calibration process, were converted to air excess ratio distribution. This investigation showed instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

  • PDF

산소부화와 유인공기를 이용한 벤츄리형 후연소기의 오염물질 저감에 관한 연구 (A Study on the Pollutants Reduction of Venturi Type After-burner by oxygen enrichment and Induced Air)

  • 오세원;박준홍;이용후;이진석;이도형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.845-851
    • /
    • 2003
  • The purpose of this experimental study is to investigate the quantitative pollutants reduction by oxygen enrichment and induced air effect in venturi type after-burner. For this purpose, CO, $CO_2$, $O_2$. and HC concentrations were measured before and after the after-burner by changing the Oxygen flow rate and area ratio which is defined as the ratio of air inducing area divided by total area. As results of this study, when the area ratio were increased, the emission reduction effect was increased even less oxygen flow rate. In that case when oxygen was injected too little, the pollutants were increased.

분리형 에어컨의 실내기 냉매 소음 저감 분석 (Analyzing for Refrigerant Induced Noise for Split type Air Conditioner Indoor Unit)

  • 한형석;시게오 아오야마;모진용;이재권;송용재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.421-426
    • /
    • 2005
  • For the air-conditioner, refrigerant induced noise and vibration should be the problem when it reduced airflow rate in order to reduce the noise at low mode. With the test, it could be verified that one of the main reason for refrigerant induced noise were the velocity and flowing induced force of the refrigerant at the inlet of evaporator. So in order to reduce this velocity with same mass flow rate of refrigerant, quality at the evaporator inlet should be minimized. And in order to reduce flowing induced force of the refrigerant, flowing direction change should be eliminated. So in this paper, it would like to review the characteristics of refrigerating cycle at first and find how the quality and flowing induced force can be minimized.

  • PDF

대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정 (Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant)

  • 박건우;유호선
    • 플랜트 저널
    • /
    • 제14권2호
    • /
    • pp.39-44
    • /
    • 2018
  • 본 연구에서는 870 MW 대형 석탄화력 발전소에서 출력을 고정시키고 과잉공기비 조정만으로 통풍계통 안정 및 보일러 효율에 어떠한 변화가 있는지를 분석하였으며 이에 따른 적정 과잉공기비를 선정하였다. 과잉공기비 조정에 따라 공기예열기 압력강하, 유인송풍기 실속여유 등이 변하므로 통풍계통 안정화를 위해 적정 과잉공기비 선정은 반드시 필요하다. 따라서 본 연구에서는 과잉공기비를 통상 운전 값인 1.153에서 운전지침서상의 하한 값인 1.127까지 단계적으로 조정하여 공기예열기 압력강하, 유인송풍기 1차 실속여유, 보일러 효율, 각종 손실 등을 측정하였고 보일러 효율도 동등수준이상으로 유지하면서 통풍계통도 위험수준에서 안전하게 이격시켜 안정화에 기여할 수 있는 적정 과잉공기비를 선정하였다. 적정 과잉공기비는 운전지침서 상의 하한 값인 1.127까지 낮추어 운전하는 것이 바람직하다고 판단된다.

  • PDF

연면방전의 플라즈마 화학처리에 의한 유해가스제어 성능에 관한 연구 (A Study on the Control Performance for Hazardous Gases by Surface Discharge induced Plasma Chemical Process)

  • 이주상;김신도;김광영;김종호
    • 한국대기환경학회지
    • /
    • 제11권2호
    • /
    • pp.185-190
    • /
    • 1995
  • Recently, because of the worse of the air pollution, the excessive airtught of building and the inferiority of air conditioning system, the development of high efficiency air purification technology was enlarged to the environmental improvement of an indoor or a harmful working condition. The air purification technology has used chemical filters or charcoal filters or charcoal to remove hazardouse gaseous pollutants (SO$_{x}$, NO$_{x}$, NH$_{3}$, etc.) by air pollutant control technology, but they have many problems of high pressure loss, short life, wide space possession, and treatment of secondary wastes. For these reason, the object of reasearch shall be hazardous gaseous pollutants removal by the surface discharge induced plasma chemical process that is A.C. discharge of multistreams applied A.C. voltage and frequency between plane induced eletrode and line discharge eletrode of tungsten, platinum or titanium with a high purified alumina sheet having a film-like plane. As a result, the control performance for hazardous gaseous pollutants showed very high efficiency in the normal temperature and pressure. Also, after comtact oxidation decomposition of harmful gaseous pollutants, the remainded ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.rea.

  • PDF