• 제목/요약/키워드: Induced Draft Fan

검색결과 11건 처리시간 0.027초

발전소 통풍계통의 가변속 적용 후 진동특성에 관한 연구 (Study on Vibration Characteristics after Applying Variable Speed Control to Constant Speed Fans used in a Power Plant)

  • 조철환;송오섭;양경현;김계연;조성태;문현동
    • 동력기계공학회지
    • /
    • 제13권6호
    • /
    • pp.88-94
    • /
    • 2009
  • In this paper, vibration characteristics after applying variable speed control to fans with a rated speed used in a power plant are studied by performing experiments and analyzing finite element models. Then the campbell diagram is presented to verify the reason of the abnormal vibration measured from fan structure during variable operation of Forced Draft Fan & Induced Draft Fan. According to results, it is found that amplitude of acceleration increases abruptly when a 2X harmonic component meets the natural frequency of fan rotor. Therefore it is very important thing that investigate exactly dynamic characteristics for the rotor at variable speed zone before applying variable speed control to a rotor with a rated speed.

  • PDF

대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정 (Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant)

  • 박건우;유호선
    • 플랜트 저널
    • /
    • 제14권2호
    • /
    • pp.39-44
    • /
    • 2018
  • 본 연구에서는 870 MW 대형 석탄화력 발전소에서 출력을 고정시키고 과잉공기비 조정만으로 통풍계통 안정 및 보일러 효율에 어떠한 변화가 있는지를 분석하였으며 이에 따른 적정 과잉공기비를 선정하였다. 과잉공기비 조정에 따라 공기예열기 압력강하, 유인송풍기 실속여유 등이 변하므로 통풍계통 안정화를 위해 적정 과잉공기비 선정은 반드시 필요하다. 따라서 본 연구에서는 과잉공기비를 통상 운전 값인 1.153에서 운전지침서상의 하한 값인 1.127까지 단계적으로 조정하여 공기예열기 압력강하, 유인송풍기 1차 실속여유, 보일러 효율, 각종 손실 등을 측정하였고 보일러 효율도 동등수준이상으로 유지하면서 통풍계통도 위험수준에서 안전하게 이격시켜 안정화에 기여할 수 있는 적정 과잉공기비를 선정하였다. 적정 과잉공기비는 운전지침서 상의 하한 값인 1.127까지 낮추어 운전하는 것이 바람직하다고 판단된다.

  • PDF

발전소 통풍계통의 가변속 운전을 위한 최적 설계조건에 관한 연구 (Study on Optimum Design Condition for Variable Speed Control of Rated Speed Fans used in a Power Plant)

  • 조철환;양경현;정남근;김봉진
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.30-35
    • /
    • 2010
  • Recently, the large capacity draft fans in power plants had been changed to variable speed type to educe the power consumption. But the fan experienced the unexpected vibration at specific speed regions. In this study, the high vibration frequency of the fan was confirmed and the natural frequency of the rotor were measured and analyzed by FEM programs. It was analyzed that the vibration was caused by the resonance at the frequency, 30.7Hz. So, the rotor vibration characteristic was changed by adjusting the distance between the shaft bearings. It was conformed the high vibration was disappeared over the all operation speeds.

습식 배연탈황 시스템의 효율 향상을 위한 전산해석 (Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas)

  • 황우현;이경옥
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권2호
    • /
    • pp.161-171
    • /
    • 2014
  • 본 논문에서는 CFDRC 사의 상용 CFD 소프트웨어인 CFD-ACE+로 전산유체역학 기법을 적용하여 수치 해석을 수행하여 배연탈황 설비에서 Induced Draft Fan(I.D.Fan) 출구부터 Booster Up Fan(B.U.Fan) 입구까지 난류 유동장과 연소 유동 문제를 모사하여 배기가스 계통 설비의 유동 특성을 해석하였다. 배기가스가 I.D.Fan 출구 ~ B.U.Fan 입구 구간을 적정속도로 균일하게 유동하여 B.U.Fan로 균일하게 유입되도록 하며 압력손실이 적게 발생하도록 설계기준 보일러 부하와 최대연속 정격유량의 보일러 부하에서 이 구간의 안내깃을 검토하였다. 검토한 결과에 대해 CFD 해석을 수행하여 I.D.Fan 출구에서 안내깃을 제거하고 B.U.Fan 입구 전에 안내깃을 보강할 수 있도록 설계를 변경하였다. 배기가스 계통에 변경된 설계를 적용하여 수치모사한 결과에서 배연탈황 설비 내부의 배기가스 압력손실이 줄어들고 유속과 유선이 균일하게 유동할 수 있어 배연탈황 시스템의 효율이 향상한 것을 확인하였다.

초초임계압 발전소 보일러 제어전략 설계 (The Strategy Design of Control Logic for Ultra Super-Critical Power Plant Boiler)

  • 박두용;김병철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.223-224
    • /
    • 2008
  • 초초임계압 화력발전 제어계통 설계와 관련하여 보일러 제어시스템의 기본 요건인 제어전략을 구현하기 위해 현재 표준화력 500MW 제어시스템과 제어로직을 기반으로 1000MW급에서 필요로 하는 새로운 구조의 제어에 요구되는 제어전략에 대해 각종 제어 운전 모드의 구성과 각 운전 모드에서의 제어전략을 개발하고 있다. 최신제어시스템에서 중요하게 취급되는 자동 플랜트 제어(Automatic Plant Control, APE)의 각종 제어전략 구성에 중점을 두고 있으며 Unit Master Control, Boiler Master Control, Turbine blaster Control, Throttle Pressure Control, Fuel/Air Master Control, Forced Draft Fan Control, Induced Draft Fan Control, Primary Air Fan, Feed Water Master Control, Super Heater/Reheater Steam Temp Control 등의 제어전략을 논하고, 실제 프로세스 응단특성 파악을 위해 국내 신규발전소를 방문하여 수집한 프로세스 응답시험 결과와 특성을 분석하고 USC에 적용하기위한 보일러 제어전략에 대해 논하고자 한다.

  • PDF

석탄화력발전소의 공기 및 가스시스템 모델에 관한 연구 (A Study on Air and Gas System of Coal Fired Power Plant)

  • 정환주;김태현;유영재;장영학;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.283-285
    • /
    • 2002
  • Boiler combustion systems are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems. dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, pulverizer, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

석탄화력발전소 연소계통의 해석을 위한 모델개발 (Development of Analysis Model for Combustion System of Coal Fired Power Plant)

  • 정환주;박용섭;김성환;장영학;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.392-394
    • /
    • 2001
  • Coal power plants are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF

냉각탑의 방사소음특성에 관한 연구 (A Study on the Noise Characteristics of Cooling Tower)

  • 박보용;김인수;이상환
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.361-374
    • /
    • 1996
  • In general, a cooling tower has two major noise sources, one is the fan and the other is the falling water. The fan noise is produced by passage of its blades through the air and radiates from the fan stack. Noises from the falling water are caused by splashing and dropping of water cascading over the internal filler of the cooling tower and into the basin and radiate from the louvered face. In this paper, the noise measurements and its frequency analysis are carried out for the locations facing the louvered side and near the fan stack referring the related code and standards in order to study the noise characteristics of the induced-draft cooling tower, especially for the buildings. As a result, it is found that for every doubling of distance from the noise source the noise level decreases by 2~4dBA in the near field with reflect surfaces and decreases by about 6dBA also in the far field without reflect surfaces. As a supplement to the noise measurements, a computer program with simple algorithm is developed in order to estimate the noise level at a distance from the cooling tower, so that the user could apply and modify it for the particular boundary conditions easily.

  • PDF

500MW 발전소에서 협소 공간 내 대형 덕트 설계의 최적화 (Optimization of the Design of Large Ducts with the Space Constraint in 500MW Power Plant)

  • 황우현;이경옥;조용기
    • 한국환경과학회지
    • /
    • 제18권7호
    • /
    • pp.755-765
    • /
    • 2009
  • Some sections of the exhaust system to determine the shape of the duct is to suffer the difficulties by space constraints to install new equipment of the environment post-treatment for existing operation of the power plants. In this paper the large duct in flue gas desulfurization equipments of the 500MW coal-fired power plant on the current operation is numerically analyzed from induced draft fan exit to booster up fan inlet section which is in the narrow space of the exhaust system with four times bending and is connected to emergency duct to bypass the exhaust gas on the emergency operation. The procedure and method using computational fluid dynamics are proposed to maintain the stability of the guide vane with the uniform flow and a minimum pressure loss of exhaust gas in the case of normal and emergency operation between the direction of the flow of exhaust gas duct at different.

석탄화력발전소 보일러 노내압력 제어알고리즘과 분산제어시스템의 개발 (The Development of Boiler Furnace Pressure Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;허광범;박두용;이흥호
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.117-126
    • /
    • 2013
  • This paper is written for the development and application of boiler furnace pressure control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. The control algorithms were designed in the shape of cascade control for two parts of furnace pressure control and induced draft fan pitch blade by standard function blocks. This control algorithms were coded to the control programs of distributed control systems. The simulator for coal-fired power plant was used in the test step and automatic control, sequence control and emergency stop tests were performed successfully like the tests of the actual power plant. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.