• Title/Summary/Keyword: Indoor-air

Search Result 2,362, Processing Time 0.034 seconds

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

The Effect of The Index of Indoor Environment on The Productivity (실내환경지수가 생산성에 미치는 영향)

  • Kim, Myung-Ho;Lee, Ye-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.615-621
    • /
    • 2018
  • To enhance the energy saving and comfort of indoors, this study performed a stimulation of sound fluctuation, color temperature, and aroma. The experiment with EEG, HRV, and Vibra images was conducted in an environmental test room with a temperature of $25[^{\circ}C]$, relative humidity of 50[RH%], air current speed of 0.002[m/s], and illuminance of 1000[lux]. The stimulation experiment set up different sensory stimulation conditions, such as before exposure, single-sensory stimulation of fluctuation a=1.106 jazz music, single-sensory stimulation of RED color lighting, single-sensory stimulation of scent aroma, and multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma. After the multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting and scent aroma, the capacity for work and attention were increased, and the stress index and fatigue degree were decreased. In addition, multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma were effective in maintaining a stable heart and health. In addition, the Vibra image appeared to decrease tension/anxiety and stress. The multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma help increase the Neuro-energy more than that by no exposure and single-sensory stimulation.

A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea (국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • In this study, a simulation program has been developed to predict the performance of energy recovery ventilators fur various indoor and outdoor conditions. In order to get a fundamental data about domestic air condition, the heat recovery ventilator is selected with the product of the wind quantity $250m^3/h$ Japanese M companies which are satisfied at High Efficiency Certification Standards. At the case on which the heat recovery ventilator is established, heating load decreases by 69.1% and cooling load decreases by 59.4% in Seoul, and heating load decreases by 66.4% and cooling load decreases by 59.6% in Pusan. The maximum humidification load of winter or summer time with $0.737{\ell}/h$ or $1.008{\ell}/h$ occurred in March from Kangnung or August from Mokpo respectively. In Southern part region and East Sea of winter time, the condensation or frost on exhaust side dose not occurred on exhaust side, but the area of that outside is occurred. Therefore, the preventive measure from the area except a southern part region and the east coast area must be considered, in order to condense or frost not to occur on exhaustion side in winter.

Artificial Spawning, Larval and Spat Developments of the Bay Scallop, Argopecten irradians (해만가리비, Argopecten irradians의 인공산란과 유생 및 치패의 발생)

  • Oh, Bong-Se;Jung, Choon-Goo;Kim, Sook-Yang
    • The Korean Journal of Malacology
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • Artificial spawning, larval and spat developments of the bay scallop, Argopecten irradians, which was transplanted from China on 16 August 1996, were investigated monthly until August 1997 in the Deukyang Bay, Jangheung-gun, Jeollanam-do, Korea. Sufficient amount of cultured microalgae supplemented seawater were supplied as food (6 kinds of phytoplankton) for fully grown adult individuals at 17.1-23.2$^{\circ}C$ for 44 days. A total of 45,320,000 eggs were spawned by way of 2 times of artificial spawning inductions such as exposure stimulus to the air and thermal shock (with water temperature) on 29 January and 31 January in 1997. Artificially fertilized eggs were developed to D-shaped larvae (77.5 ${\times}\;63.8\;{\mu}m)$ and metamorphosed to larvae (191.8 ${\times}\;181.2\;{\mu}m)$ 181.2 m) in the attached larval stage on the collectors. A total of 110,000 spats (average 3.04 mm in shell length) were produced at 22.8-26.3$^{\circ}C$ and 31.0-34.4 psu in the indoor rearing tank from 14 February through 7 May in 1997. In case of Argopecten irradians, if the attached larvae in the attachment stage are detached from the collector, they could not live. Accordingly, it is assumed that survival (%) of the attached larvae of A. irridians showed very low because of weak power attached to the collector due to the small number of the byssuses of the attached larva, not the short attachment period by the byssus as seen in other scallops such as Argopecten balloti.

  • PDF

Reduction of Particulate Matters Levels in Railway Cabins in Korea

  • Park, Duck-Shin;Kwon, Soon-Bark;Cho, Young-Min;Park, Eun-Young;Jeong, Woo-Tae;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • Objectives: High concentrations of airborne particulate matters (PM) can affect the health of passengers using public transportation. The objectives of this research were to develop a PM control system for a railway cabin and to evaluate the performance of the device under conditions of an actual journey. Methods: This study measured the concentrations of $PM_{10}$ and $PM_{2.5}$ simultaneously in a reference cabin and a cabin with the PM control device. Results: The average $PM_{10}$ concentration in the reference cabin was 100 ${\mu}g/m^3$, and the $PM_{10}$ concentration in the cabin with the control device was 79 ${\mu}g/m^3$. While the overall control efficiency of the control device was 15.4%, reduction was more effective for peak $PM_{10}$ concentration. However, $PM_{2.5}$ levels did not differ greatly between the reference cabin and the cabin with the control device. The ratio of $PM_{2.5}$ to $PM_{10}$ was 0.37. $PM_{10}$ concentrations in cabins were not associated with ambient concentrations, indicating that the main sources of $PM_{10}$ were present in cabins. Additionally, average $CO_2$ concentration in the cabins was 1,359 ppm, less than the maximum of 2,000 ppm set out by the Korean Ministry of Environment's guideline. The $CO_2$ concentration in cabins was significantly associated with the number of passengers: the in-cabin concentration = $23.4{\times}N+460.2$, where N is the number of passengers. Conclusions: Application of the PM control device can improve $PM_{10}$ concentration, especially at peak levels but not $PM_{2.5}$ concentration.

Risk Assessment of Nitrogen Dioxide for Hematological and Biochemical Parameter in Mice (Mice를 이용한 혈액 및 생화학적 특성에 대한 Nitrogen Dioxide의 위해성 평가)

  • Jeong, Seong-Wook;Han, Yong-Soo;Park, Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.16 no.5
    • /
    • pp.665-670
    • /
    • 2007
  • In this study, we evaluated the property change and relationship between hematological and biochemical parameters in exposure group and control group by multiple inhalation exposure, of $NO_2$. In case of leukocyte, change of hematological property increased significantly in statistics (p<0.05) in mice experiment. in case of hematocrit of exposure group, it was of decreased significantly in statistics. the tendency of hemoglobin and hematocrit was similar to all for three case. in case of methmoglobin that of the exposure group in mice experiment was meaning increased(p<0.05). For the $NO_2$ influence in biochemical property, total protein and triglyceride was decreased but not significant in statistics, albumin was decreased in the exposure group in the animal experiments, blood urea nitrogen and creatinine increased significantly in statistics in the animal experiments. uric acid and lactate dehydrogenase in serum increased significantly in the exposure group. We have to evaluate risk assessment for the $NO_2$ of indoor air pollutant in low concentration and long time.

Comparison of single-span plastic greenhouse in Korea and high tunnel in North America (우리나라 단동 비닐하우스와 북미지역 하이터널의 비교)

  • Nam, Sang-Woon;Both, Arend-Jan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.505-512
    • /
    • 2011
  • Structural characteristics for standard models of single-span plastic greenhouse in Korea and high tunnels in North America were analyzed, and comparative analysis for greenhouse environments measuring in Korean farmhouse and Rutgers high tunnel was carried out to find structural and environmental improvements of single-span plastic greenhouses that occupy most of Korean greenhouse. Widths of high tunnels are similar to single-span plastic greenhouses but their heights are high comparatively and their side heights are fairly higher than single-span plastic greenhouses specially. Rafters, which are main frames, section sizes of high tunnels are bigger and their intervals are wider than single-span plastic greenhouses. Relative bending resistances compared with representative Korean greenhouse were analyzed by 0.92 to 1.42 in single-span plastic greenhouses, and 1.38 to 2.96 in high tunnels. Frame ratios of single-span plastic greenhouses were 6.8 to 8.6%, and those of high tunnels were 5.5 to 8.7%. We analyzed air temperatures and solar radiations measured in single-span plastic greenhouse and high tunnel on clear days in late March. There were outside temperatures in generally similar range, and judging by rise of indoor temperatures, ventilation performance of high tunnel is more excellent than single-span plastic greenhouse. Solar radiations of two areas were no big difference but light transmittance of high tunnel was a little bit higher than single-span plastic greenhouse. Single-span plastic greenhouses are disadvantageous in environmental managements such as ventilation performance and light transmittance because distance between greenhouses is too narrow and length of greenhouse is too long compared to high tunnels. To get the environmental improvement effects as well as to increase the structural resistance of single-span plastic greenhouses are achievable by widening the width of greenhouse in possible range, widening the space between rafters, and enlarging the section size of rafters. Also, we need to secure enough distance between greenhouses and to restrict the length of greenhouse by maximum 50 m in order to improve the ventilation performance and the light transmittance.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

A Study on the Low Concentration Carbon Dioxide Adsorbent and Optimal Conditions (저농도 이산화탄소 포집용 흡착제 개발 및 최적조건에 관한 연구)

  • Lee, Ju-Yeol;Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Park;Hwang, Yoon-Ho;Song, Hyung-Jin;Lee, Sang-Bong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, $CO_2$ adsorbent was developed for removing low concentration of $CO_2$ in multiple-use facilities. The efficiency of the adsorbent which was improved selective $CO_2$ adsorption capabilities was evaluated. The pellet type adsorbent was modified from a commercial zeolite with mixing LiOH, binder, additives, and $H_2O$. Column tests showed over 90 % of $CO_2$ was adsorbed within 400min. Chamber tests including batch and continuous types were performed for evaluating the adsorbent module. By batch tests, it was evaluated that about 92% of $CO_2$ was removed within 30 min. By continuous tests, 70% of $CO_2$ was removed within 30 min. It was analyzed that over 2,500 ppm of $CO_2$ was continuously removed as shown chamber tests. The reproducibility tests repeatedly performed for 15 days shows that over 1,000 ppm of $CO_2$ was continuously removed. Adsorption capacity of the developed adsorbent was 5.0mmol $CO_2/g$ adsorbent which was analyzed by TGA. It was estimated that the modified adsorbent was applicable to low $CO_2$ concentration and low temperature of indoor environment.