• Title/Summary/Keyword: Indoor radon gas

Search Result 48, Processing Time 0.021 seconds

Assessment of radon potential in the areas covered with granite and gneiss in Korea

  • Je Hyun-Kuk;Chon Hyo-Taek
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.501-503
    • /
    • 2003
  • Soil-gas radon level and other atmospheric factors have been measured at residual soil profiles that overlie granite bedrock which consists of major geology in Korea for 6 months from November, 2000 to April, 2001. Seasonal variations of soil-gas radon concentration are generally of greater magnitude than day-to-day fluctuations. The highest radon concentrations of 5,131 pCi/L measured during winter season and the lowest radon concentrations of 107 pCi/L during spring season. Two study areas, Bongcheon-dong(granite bedrock) and Seongnam-Yongin(gneiss bedrock) were investigated to assess the radon potential according to their field survey and emanation tests. The mean values of radon decrease in sequentially from Suji-A(813 pCi/L)>Suji-B(757 pCi/L)>Bundang-B(691 pCi/L)>Bundang-A(643 pCi/L)>Bongcheon-dong(513 pCi/L). Estimated soil-gas radon potential using maximum radon emanation ratios of each study area decreases in the order of Bongcheondong(950 pCi/L)>Suji-B(524 pCi/L)>Bundang-A(437 pCi/)>Bundang-B(259 pCi/L)>Suji-A(230 pCi/L) areas. The values of indoor radon and its daughter product concentrations in Bongcheon-dong area show that indoor basement rooms in poor ventilation condition could be classified as extremely high radon risk location of more than 4 pCi/L Rn and 0.02 WL.

  • PDF

Evaluation of Decreasing Concentration of Radon Gas for Indoor Air Quality with Magnesium Oxide Board using Anthracite (안트라사이트를 활용한 산화마그네슘 보드의 실내 공기질 중 라돈가스 농도 저감 평가)

  • Pyeon, Su-Jeong;Lim, Hyun-Ung;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • Radon gas, which is present on the earth, is a primary carcinogen released from rocks, soil, building materials, etc., and exists as a unique gas phase. In order to solve the risk of radon gas, we evaluated the basic performance which can be used as indoor finishing materials in addition to the radon gas reduction properties of the matrix using anthracite. An anthracite used as a conventional filter material was used to produce a matrix, and a test was conducted to replace the gypsum board, which is one of the building materials used in the existing room. As the anthracite replacement ratio increases, flexural failure load strength increases and thermal conductivity tends to decrease. Depending on the thickness of the board, the reduction performance of radon gas shows a slight difference.

Prediction of Indoor Radon Concentration through the Exhalation from Korean Yellow Residual Soil, Hwangtoh as a Building Material

  • LEE, Ju Yong;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.122-133
    • /
    • 2021
  • The radon gas from nature mainly considers a cause of radon problems, and it is closely affect human life cycle. Korean yellow residual soil, Hwangtoh, widely used as a building material, is considered to be one of major sources of indoor radon. However, there have, as yet, been no studies about radon from Hwangtoh in mass market brands. Here, we investigated the indoor radon concentrations and exhalation rates in four Hwangtohs from different brand names and regional features. The Closed Chamber Method (CCM) conducted by a Continuous Radon Monitor (CRM) has been used for the rates of radon exhalation. Based on equations of previous references, the indoor radon concentrations were deducted. As a result, the radon surface exhalation rates resulted in the 1.4208 to 3.0293 Bq·㎡·h-1 range. Significant differences were found among Hwangtohs according to production regions. Materials with higher radon concentration required a longer time to reach a quasi-steady state in a given environment, in other words, the number of half-life cycles increased from a set starting point. The experimentally identified Hwangtohs demonstrated its safety for construction purposes. There exists, so far, a possibility to exert influence radon emanation due to unidentified factors. Therefore, it is necessary to corroborate with more research by increasing the number of Hwangtohs, considering the other references reported high radon exhalation rates. In addition, it is highly recommended that the radon exhalation rates should be measured for all building materials for preventing human health before the material usage.

Effects of radon and its management (라돈의 영향과 관리)

  • Cho, Seung Yeon;Kim, Seon Hong;Kim, Min Jun
    • Journal of odor and indoor environment
    • /
    • v.16 no.4
    • /
    • pp.297-307
    • /
    • 2017
  • As radon is a naturally occurring radioactive gas that can cause lung cancer and is classified as a Group 1 carcinogen, it is essential for the public to be aware of what radon is, and how to manage radon. Therefore, general information on radon, as well as its health risks, measurement methods, mitigation methods and suggestions for its management are addressed in this article. Over the last one to two decades, a number of wide-ranging studies on radon measurement and mitigation have been conducted in Korea, and the results of each study are comparable to the research achievements of other developed countries. For this reason, it is time to systematically establish a well-made Korean radon management organization.

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

Influence of Ventilation on the Subway Radon Level (환기에 의한 지하 역의 라돈농도 변화)

  • 박덕신;정우성;정병철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.62-67
    • /
    • 2000
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced by the radioactive decay of the element radium. And, radon is one of the major indoor air pollutants. Radon moves into the underground space through various routes and is considered to cause lung cancer by hurting the lung tissues. In this study, we measured the subway radon level at 9 stations of 3 lines. According to test results, we can figure out the concentration of radon by lines, times, and measuring points. So, it was found that ventilation conditions are the most important factors in the subway air quality. Finally, we suggested effective and economic management methods of air pollution in the subway.

  • PDF

Radon Concentration in Various Indoor Environment and Effective Dose by Inhabitants in Korea (국내 다양한 실내환경에서 라돈농도 및 거주자의 실효선량 평가)

  • Lee, Cheol-Min;Kim, Yoon-Shin;Roh, Young-Man;Kim, Ki-Youn;Jeon, Hyung-Jin;Kim, Jong-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.264-275
    • /
    • 2007
  • The objective of this study was to offer basic and scientific data for decision-making of policy for improvement and management of radon, natural radiation gas, in Korea and to form the foundation of radon related international cooperation. Therefore, this study collected and re-analysed the articles on exposure of radon in various indoor environment in journals related environment in Korea since 1980 and estimated the annual exposure dose and effective dose by exposure of radon received by inhabitants in them. The highest pooled average radon concentration of $50.17{\pm}4.08\;Bq/m^3$ (95% CI : $42.17{\sim}58.17\;Bq/m^3$) was found in dwelling house among various indoor environment. All of pooled average radon concentration estimated in this study showed lower than the guideline concentration ($148\;Bq/m^3)$ of US EPA and the Korean Ministry of Environment. The annual effective dose received by inhabitants in various indoor environment was estimated 1.071 mSv/yr. That is equal to annual effective dose (1.0 mSv/yr) by exposure of radon estimated by UNSCEAR.

A Study on Indoor Radon Concentration among Vulnerable Households in Korea (국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구)

  • Zoo, Duck Hyun;Park, Ki Ho;Jeong, Hui Won;Lim, Hyeong Jun;Bok, Dong Seok;Yun, Dong Won;Min, Kyung Hwan;Mun, Kyung Deok;Kim, Jeong Un;Lee, Ji Min;Choi, Won Yong;Kim, Sung Yoon
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.2
    • /
    • pp.61-70
    • /
    • 2015
  • Objectives: The purpose of this research was to examine radon exposure in terms of the relationship between the living environment and indoor radon concentrations among vulnerable households. Methods: Nationwide, 1,129 subjects were selected using personal questionnaires for adequately understanding the living environment, installation of E-PERM radon gas detectors, and investigation of the structure of the housing. Results: The mean concentration of indoor radon for all subjects was $130.2Bq/m^3$ (GM=101.7), and a total of 438 subjects (38.8%) exceeded the recommended standards ($148Bq/m^3$) for public facilities by the Ministry of the Environment. By location, the highest concentrations ($164.3Bq/m^3$, GM=124.1) were seen in North Chungcheong Province. In the case of the Seoul/Gyeonggi Province metropolitan area, they showed $125.6Bq/m^3$ (GM=105.1) and $118.9Bq/m^3$ (GM=96.5), respectively. By type of housing, indoor radon concentrations in single-family housing were higher than in row/multi-family housing (p<0.01). Although indoor radon concentrations raised in accordance with year of construction (p<0.05), the difference between indoor radon concentrations in underground residences was not observed to be statistically significant (p=0.633). Conclusion: More studies are necessary in the future regarding the difference in indoor radon concentrations that may occur due to different of types of indoor construction, building materials, and the amount of building materials.

Reduction Methods of Indoor hiy Quality on the Subway Station using by Ventilation (환기를 이용한 지하 역 실내 공기질 개선 방안)

  • 박덕신;정병철;조준호;정우성
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.139-146
    • /
    • 2001
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced radioactive decay of the element radium. And, radon is one of the major indoor air pollutants moves into the underground space through various routes and is considered to cause lung c hurting the lung tissues, In this study, we measured the subway radon level at 9 stations o According to test results, we can figure out the concentration of radon by lines, times, and m points. So, it was found that ventilation conditions are the most important factors in the su quality. Finally, we suggested effective and economic management methods of air pollution subway.

  • PDF

A Study on the Improvement of Indoor Air Quality in Apartment Buildings (공동주택의 실내공기환경 개선에 관한 연구)

  • Lee, S.H.;Park, J.C.;Rhee, E.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF