• Title/Summary/Keyword: Indoor quality

Search Result 1,346, Processing Time 0.029 seconds

A Study on the Field Evaluation about the Indoor Air Quality of Schools Newly Built in Changwon (창원지역 신축학교의 실내공기질 현장평가 연구)

  • Yoo, Jong-Hoon;Kang, Eun-Hye;Son, Young-Hwan;Ha, Suk-Yong;Choi, Jeong-Min
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1244-1249
    • /
    • 2006
  • Because students are spending more time in their classroom for learning and study, indoor air quality problems in school classrooms are very important. when the classroom is built for the first time, namely newly built school, the selection of inside finishing material is directly connected with indoor air quality problems especially with HCHO and TVOC. But until now, there is no plenty of study about this. Moreover, there are some concerns about the desks and chairs which are used in classroom will affect the air quality. but almost no study is being made at all Therefore, this study focuses on the field survey and analysis of classroom indoor air quality in newly built schools in Changwon. In this study filed surveys and analysis are conducted as follows. 1) The effect of the material difference in general classroom. 2) The effect of the material and loading ratio difference in special classroom. 3) The effect of the desks and chairs in general classroom.

  • PDF

Seasonal variations of volatile organic compounds (VOCs) in indoor air of daycare centers (보육시설 실내공기 중 휘발성유기화합물(VOCs)의 계절적 농도변화에 대한 연구)

  • Jang, Seong-Ki;Chun, Jae-Young;Kim, Sung-Youn;Park, Suk-Young;Ryu, Jung-Min;Lim, Jung-Yeon;Lee, Woo-Suk
    • Analytical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.474-482
    • /
    • 2007
  • Daycare centers are an important indoor environment for pre-school children and exposure area with potential harmful health effects for infants and children who spend most of their daily life. Sampling was undertaken at 29 daycare centers located Seoul in Korea from January, 2006 to December 2006. The target compounds were 7 individual volatile organic compounds (benzene, toluene, ethylbenzene, m,p-xylene, styrene, o-xylene, TVOC). The mean concentrations of TVOC, toluene, m ,p-xylene, ethylbenzene, benzene and styrene in daycare centers were $318.7{\mu}g/m^3$, $51.6{\mu}g/m^3$, $11.7{\mu}g/m^3$, $6.5{\mu}g/m^3$, $4.2{\mu}g/m^3$, $3.6{\mu}g/m^3$, respectively. Toluene occupied 17.6 % of the concentration of individual VOCs. The ratio of indoor and outdoor (I/O) of TVOC and toluene were 2.0 and 1.6, respectively. The results of characteristics according to a season of a year, the concentration of TVOC were measured $433.9{\mu}g/m^3$, and these concentrations during third quarter of the year in summer were higher than the other season. In the other four seasons, TVOC were measured 280.5 in winter, 298.3 in spring and $264.6{\mu}g/m^3$ in fall, respectively.

A Fundamental Study about a Quality Certification of 3D Precision Indoor Geospatial Information - Focused on Yeongdeungpo Station - (3차원 정밀 실내공간정보 품질인증 방안에 관한 기초연구 - 영등포역을 중심으로-)

  • Lee, Ki Sung;Jeong, In Hun;Choi, Yun Soo;Kim, Sang Bong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.3-14
    • /
    • 2015
  • As buildings in the downtown area, such as the complex building connected to the skyscraper and the underground facility, have become large and complex, the range of target domain of the space information service is rapidly expanding to the interior space; it is considered that this change will create various demands of service such as the indoor geospatial information base safety, the management of facility, and the interior navigation in the future, along with spread of mobile devices and development of IT technology. As for the indoor geospatial information, however, there is no certification standard of the established indoor geospatial information data quality, so preparing the certification standard is urgent. Thus, this study reviewed foreign and domestic research cases and prepared measures for quality verification of the indoor geospatial information to conduct a verification test of the Yeongdeungpo Station indoor geospatial information, established in 2014. As a result, through the verification test of the method and standard of the indoor geospatial information quality certification suggested by this research, it was identified that the uniform and higher quality data could be classified, and the types of error high frequently occurring could be investigated. These results are expected to be utilized as the basic data for establishing quality certification system for the indoor geospatial information in the future.

Indoor Link Quality Comparison of IEEE 802.11a Channels in a Multi-radio Mesh Network Testbed

  • Bandaranayake, Asitha U;Pandit, Vaibhav;Agrawal, Dharma P.
    • Journal of Information Processing Systems
    • /
    • v.8 no.1
    • /
    • pp.1-20
    • /
    • 2012
  • The most important criterion for achieving the maximum performance in a wireless mesh network (WMN) is to limit the interference within the network. For this purpose, especially in a multi-radio network, the best option is to use non-overlapping channels among different radios within the same interference range. Previous works that have considered non-overlapping channels in IEEE 802.11a as the basis for performance optimization, have considered the link quality across all channels to be uniform. In this paper, we present a measurement-based study of link quality across all channels in an IEEE 802.11a-based indoor WMN test bed. Our results show that the generalized assumption of uniform performance across all channels does not hold good in practice for an indoor environment and signal quality depends on the geometry around the mesh routers.

A Study on the Standards of Volatile Organic Compounds in Indoor Air of Office (사무실 실내공기중 휘발성유기화합물의 기준설정에 관한 연구)

  • Kim, Yoon-Shin;Lee, Cheol-Min;Roh, Young-Man;Lee, So-Dam;Sohn, Jong-Ryeul;Kim, Seok-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.413-427
    • /
    • 2006
  • It is necessary to study and develop guidelines for providing comfort and health indoor air quality for office workers since air-tight envelope system of current office building may cause poor indoor air quality. The purpose of this study is to propose guideline for volatile organic compounds in office base on the field study, human health risk assessment and cost-benefit analysis. The field study was conducted to survey the concentrations of volatile organic compounds in indoor air of 69 offices from June to September, 2005 in Seoul and Gyeonggi-do. The rate of excess to guideline of volatile organic compounds in indoor air of new apartment on the Ministry of Environment in Korea(MOE) was surveyed 37.6% for benzene, 6.8% for toluene, and 1.5% for ethylbenzene. As the result of human health risk assessment, mean cancer risk did not exceed 10-6 which is guideline of US.EPA. Also, total hazard index did not exceed 1 which is guideline of US.EPA. Through the cost-benefit analysis of angle on the social-economics to verify the necessary to establish the standards of volatile organic compounds for improvement and development of indoor air quality in office, the present value of benefit was higher than the present value of cost. With the above considerations in mind, it is suggested that the field study for indoor air quality in offices should be expanded and human health risk assessment and cost-benefit analysis be performed th offer scientific data for decision-making of policy for improvement and management of indoor air quality in office.

Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility (유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가)

  • Koh, Yeon-Jung;Kim, Shin-Do;Park, Suk-Young;Jang, Seong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.2
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

Infant target facilities and facilities for children in elementary school Comparison and Improvement of Indoor Air Quality for Research (영유아 대상 시설의 실내공기질 특성 비교 및 개선방안에 대한 연구)

  • Seo, Byong-Won;Lee, Ju-Hwa;Park, Ji-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.591-601
    • /
    • 2013
  • In modern society, we are living indoor at 80 - 90 % or more of the day, therefore most people are exposed to unconscious indoor air pollutants by various causes. When mother and infant, whose level of immunity are weak, are exposed to polluted indoor air, respiratory diseases and atopy can occur by the growth of bacteria. Therefore, appropriate indoor air quality management is important especially at nursery, elementary school and postpartum clinic etc. In this study, we compared the characteristics of the indoor air qualities of primary school facilities and infant facilities. In this study, seasonal effects were investigated. Also the effects of individual activity area were studied for indoor air quality. During summer season(May-August), the air qualities of each 16 elementary school and nursery school were investigated. During winter season(October-december), the air qualities of each 10 elementary school and nursery school were investigated. As a result, during winter season in 10 of 16 nursery school, $CO_2$ concentration exceeded regulation level of 1000 ppm. This resulted from the operation of heating system and poor ventilation. Also the air quality of all parameters during winter season were worse than during summer, maybe due to poor ventilation. Except HCHO, the concentrations of other parameters were higher in nursery school. This seems to result from relatively low individual activity area of nursery school than elementary school. From this research, more strong regulation for ventilation and installation of air purifier should be implemented.

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province (경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성)

  • Park, Hyun-Ku;Jung, Yeon-Hoon;Kim, Byeong-Lok;Kim, Jin-gil;Shin, Hyung-Soon;Lee, Sang-Soo;Oh, Jo-Kyo
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.250-258
    • /
    • 2018
  • Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.