• Title/Summary/Keyword: Indoor pollution

Search Result 475, Processing Time 0.026 seconds

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

A study of Recognition of Indoor Air Quality of Indoor Environment at School (학교 실내 환경의 실내공기질 인식에 관한 연구)

  • Hong, Eun-Ju;Kim, Jung-Duck;Jeon, Young-Taek;Lee, Che-Won;Moon, Jeong-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.3
    • /
    • pp.51-64
    • /
    • 2007
  • This research, selected for 40 classrooms(20 old, 20 new) in chungnam area from June 22 to July 19 and from November 21 to December 30, 2003, in order to study of Recognition of Indoor Air Quality of Indoor Environment at School. we used Questionnaire for 193 health teachers, 41 teachers, and 1,359 students. The results of study are as follows. 1. To the question 'Currently Were you damage caused by classroom air?', showed that worry class teachers more than students with 43.9% of class teachers, 35.9% of health teachers and 23.5% of students. 2. To the question 'What would be an efficient way to manage classroom sanitation?', 50% of class teachers, 40.5% of health teachers and 47.4% of students wanted 'installation of air purifier.' 3. To the question 'How are you getting information about indoor air pollution?', showed that all of 3 groups get information through on TV. 4. According to survey, Health teachers who act as health supervisors appeared to have more prior knowledge air quality than class teachers and students. The results of this research show insufficient understanding of health risks from indoor air pollution, and shows possible health problems to students from school indoor air pollution. Therefore, these results suggested that a logical and systematic education program for students about the importance of indoor air quality should be carried out.

Microbiologic Pollution of Indoor Air in Industrial Work-Places (산업체 작업환경의 실내 공기에서 미생물 오염도)

  • 강경희;장명웅
    • Journal of Life Science
    • /
    • v.9 no.3
    • /
    • pp.314-327
    • /
    • 1999
  • This study was investigated to isolate identify the total bacteria and fungi from the indoor air of work-place of the shoes, paint, stainless steel, and plastic industries. The number of bacterial colonies on the nutrient agar plates were calculated by the open petridish method for 30 minutes in indoor air of work-places at the autumn and winter. The isolated bacteria were identified by Gram stain and biochemical test using API Staph and API 20E kits. The isolated fungal colonies were identified by gross appearance of the giant colonies and microscopic examination of their spore and hyphal characteristics on the slide culture method. The minimum inhibitory concentration (MIC) of several antibiotics against isolated bacteria was determined by the microdilution method with Mueller-Hinton broth. The 70-400 colonies in autumn and 54-236 colonies in winter were isolated from the indoor air of work-places of several industry. The isolation rates of Gram positive cocci, Gram positive bacilli, Gram negative bacilli, and Gram negative cocci were 46.3%, 19.8%, 17.3%, and 16.1%, respectively. In Gram positive cocci, the most strains were identified as Aerococcus spp, Micrococcus spp, and Staphylococcus spp. In Gram positive and negative bacilli, and Gram negative cocci were identified as Bacillus spp, Pseudomonas spp, and Neisseria spp, respectively. The frequently isolated fungi were Aspergillus spp, Penicillium spp and Rhizopus spp, respectively. The frequently isolated Aerococcus spp, Micrococcus spp, and Staphylococus spp were highly resistance against ampicillin, erythromycin, methicillin, and tetracycline. These results arouse our attention to microbiologic pollution in the indoor air of work-places of industries.

  • PDF

Development of Real-time Monitoring Platform for Indoor Air Quality Using Air Quality Sensors (AQ센서를 활용한 실내 대기 질 실시간 모니터링 플랫폼 개발)

  • Oh, Sang-Heon;Kim, Sung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.206-209
    • /
    • 2018
  • According to data released by the WHO(World Health Organization), the death toll from indoor air pollution in 2016 was about 3.8 million. While many people are aware of outdoor air pollution, indoor air pollution is getting less attention. Recently, however, indoor air pollution has also become a big problem, raising many issues. Frequent indoor activities such as cooking and heating produce various pollutants, which can cause children and elderly with weak immune systems to be exposed to pollutants, which can cause serious health problems such as poor lung function and respiratory diseases. Therefore, in this paper, the IoT(Internet of Things) platform that measures and monitors indoor air quality using AQ(Air Quality) sensors is developed so that data can be monitored in real time through applications and reactive web.

  • PDF

Indoor air pollution in ger, a traditional type of residence in Mongolia (몽골 울란바토르 시 전통 주거공간의 실내공기 오염 기초조사)

  • Lee, Boram;Chimeddulam, Dalaijamts;Jargalsaikhan, Khishigt;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.118-125
    • /
    • 2016
  • Objectives: The traditional type of residence in used in Mongolia, called a ger, is an important residential form and applies coal combustion for cooking and heating. The combustion of coal in ger is the major source of indoor air pollution. The purposes of this study were to measure indoor air pollution in ger and determine the effect of cooking and heating activities. Methods: Indoor temperature, relative humidity, particulate matter less than $2.5{\mu}m$ ($PM_{2.5}$) and black carbon (BC) were continuously measured for 24 hours in eight ger. The measurements were conducted in January or February 2015. Heavy metals in $PM_{2.5}$ filter samples were analyzed by ICP-MS. Results: Average indoor temperature and relative humidity were $19.6{\pm}4.6^{\circ}C$ and $21.4{\pm}5.2%$, respectively. The average indoor $PM_{2.5}$ concentration in the eight ger was $119.8{\mu}g/m^3$ and ranged from 69.4 to $202.7{\mu}g/m^3$. The peak concentrations of $PM_{2.5}$ and BC during cooking and heating periods were several times higher than the 24- hour average concentration. Conclusion: The major contributor to indoor $PM_{2.5}$ and BC concentrations in the ger was coal combustion for cooking and heating.

A Study on User's Opinion for Designing of Multi-Functional Plant Applications (복합적 기능의 식물 애플리케이션 디자인을 위한 사용자 조사)

  • Lee, Ha Na;Park, Han Na;Paik, Jin Kyung
    • Korea Science and Art Forum
    • /
    • v.37 no.4
    • /
    • pp.297-308
    • /
    • 2019
  • Air pollution due to the fine dust level updating every day, and the problem of indoor air pollution due to ventilation difficulties and indoor discharge pollutants is also serious. In order to improve the indoor air quality, the air purification effect using the plants is prominent. In this study was started to investigated the living environment of modern people, the risk of indoor air pollution and the improvement function of plants, and to activate plant application. The purpose of this study is to analyze the main functions and design status of domestic and overseas plant - related applications, and to understand the actual use of modern plant applications and to help them learn more convenient plant - related knowledge. Therefore, this paper attempted to establish a basis for suggesting a new plant application by conducting a survey on the health effects of indoor air pollution and user awareness of plant - related applications. The results and contents of the study are as follows. First, as a theoretical review, indoor air pollution is more dangerous to modern people who have a high proportion of indoor living time and adversely affects their health. In order to solve such a problem, it has been shown that air conditioning and stress reduction can be effectively achieved by placing plants in the indoor space. Second, the analysis of the previous study shows the risk of indoor air pollution and its adverse effects on health. In addition, I have been able to find some researches related to the improvement of the indoor air by using the air purifying plants, and I can see the improvement of the user's behavior through the development or improvement of the application. Third, as a result of the survey on the status of domestic and overseas plant application, the main function of the application having high installation number was watering notification, provision of basic information of plants, and most of the functions were plant discerment through cameras. Fourth, most of the survey respondents have either raised or raised plants. Those who have little experience with plant applications have also shown positive feedback in the future on the use of plant-related applications. In addition, due to social problems such as air pollution, air purification using plants and functional plants showed high interest. Based on these results, we propose the need for a multi-functional plant application that can improve the indoor air pollution and facilitate the provision of information related to it.

Relationship between Indoor and Outdoor Particulate Matter Concentrations in Japan

  • Nakai, Satoshi;Tamura, Kenji
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.68-74
    • /
    • 2008
  • We briefly show the results of indoor and personal $PM_{2.5}$ measurements in an epidemiologic study designed to evaluate the health risks of ambient $PM_{2.5}$ in Japan and the relationship between indoor and outdoor PM concentrations. The impact of indoor and outdoor PM pollution on health is described based on one morbidity study. The results of other studies on indoor $PM_{2.5}$ measurements are also described.

A Study on Plant Effects on Decontamination of Polluted Indoor Air with Formaldehyde (포름알데히드로 오염된 실내공기의 정화에 미치는 식물효과에 관한 연구)

  • Park, Soyoung;Kim, Jeoung;Jang, Young-Kee;Sung, Kijune
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.4
    • /
    • pp.147-155
    • /
    • 2005
  • This study was designed to investigate the effect of plant as a botanical air purification on the indoor pollution by formaldehyde. Three indoor plants such as Dracaena marhginata, Spathiphyllum and Dracaena reflexa, were placed in the artificially contaminated reactor under laboratory condition. Both plant and soil effects on removal of formaldehyde from contaminated indoor air were observed. Reductions in the formaldehyde levels appeared to have been associated with soil medium factors as well as plant factors. The effect of soil on formaldehyde reduction was high in the early stage of the experiment and the results suggest that sorption could be more important factor than microbial degradation in the initial dissipation of contaminants in the soil. It was suggested that the effect of plant on formaldehyde reduction might be related to the plant species, total leaf surface area of plant, degree of contribution of soil medium, and exposed concentration level. The results of this study showed that air purification using plants is an effective means of reduction on indoor formaldehyde level, though, utilization of soil media with high sorption capacity and/or supplementary purifying aids were also suggested when the source is continuous or exposed concentration level is high.

A Study on Indoor Air Quality in new Ship (새로 건조된 선박의 실내공기환경 조사 연구)

  • Doe, Geun-Young;Lee, Han-Seok;Lee, Yun-Gyu;Lee, Hyong-Ki
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.427-434
    • /
    • 2007
  • Indoor air pollution has been a critical issue as a new environmental problem and a significant amount of research has been performed on the indoor air pollution in buildings as well us those in mean of transport such as automobiles, subways, and buses. The actual condition of indoor air pollution in ships, however, was not investigated. Because airtightness of a ship is very higher than a general building and the crew spend almost all the time in indoor space of the ship during underway, indoor air quality(IAQ) of the ship is very important for their comfortableness and health. In this paper, indoor air quality of a new ship is measured and analyzed for the improvement of IAQ in ships.