• Title/Summary/Keyword: Indoor pollution

Search Result 475, Processing Time 0.025 seconds

Pproperties of formaldehyde and CO2 adsorption type matrix using TiO2 photocatalysis (광촉매를 활용한 흡착형 경화체의 포름알데히드 및 CO2 특성)

  • Lee, Won-Gyu;Pyeon, Su-Jeong;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.153-154
    • /
    • 2018
  • As the air pollution progresses, the pollution degree of the indoor air quality is increased, and when the pollution degree of the indoor air quality is increased, it causes respiratory diseases and skin diseases. In addition, volatile organic compounds are released from the materials used for architectural interior decoration, and volatile organic compounds are the main cause of polluting indoor air quality. In order to improve indoor air quality, we tried to secure indoor air quality pollution by using photocatalyst which has the function of decomposing harmful substances. photocatalyst is a material that promotes chemical reaction by absorbing light. The photocatalyst used in the experiment was TiO2, In this study, an adsorption type hardener for reducing volatile organic compounds was prepared by photocatalytic reaction. the formaldehyde and CO2 concentrations of the cured products were analyzed according to the TiO2 content.

  • PDF

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.

A Study on the Indoor Air Pollution Level and Its Health Significance in Working and Living Spaces (일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구)

  • Shin, Dong-Chun;Lee, Hyo-Min;Kim, Jong-Man;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.73-84
    • /
    • 1990
  • The study was carried out to investigate the extent of indoor air pollution in living rooms of apartment houses(residential area) and offices(traffic area A : no smoking space, B : smoking space) in Seoul and to determine the health significance of indoor air pollution. Indoor and outdoor concentrations of major air pollutants were observed simultaneously from February 13 to 17, and July 24 to 28, 1988. The concentrations of carbon monoxide(CO), nitrogen oxides(NOx), sulfur dioxide($SO_2$), carbon dioxide($CO_2$) and total suspended particulate(TSP) in living room and offices were measured and the results were summarized as follows: 1. Both in summer and in winter, the indoor concentrations of CO, $CO_2$, and TSP in offices were higher than the outdoor concentrations, on the other hand, $SO_2$ was higher in the outdoors and NOx was lower than the outdoor concentration only in office A where smoking is not permitted. 2. The indoor and outdoor pollution of offices in winter was significantly higher than that in summer, and the concentrations of CO, NOx and $SO_2$ in indoor and outdoor air in living room in winter were also higher than those in summer. These results suggest that indoor levels of air pollutants are affected by smoking and winter heating systems.

  • PDF

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.

A study on the Measurement and Improving Method of Indoor Air Quality in a Educational Facility (교육시설물의 실내공기질 측정 및 개선방안에 관한 연구)

  • Kim, Sung-Kyum;Kim, Jae-On;Cho, Chang-Yeon;Kim, Jong-Rok;Son, Jae-Ho
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.14 no.4
    • /
    • pp.43-52
    • /
    • 2007
  • People spend more than 90% of their time indoor. Nowadays as they are interested in environment much more than before, indoor air pollution has been regarded as new environmental problems. At present, an air quality check is required prior to the completion of construction. However this study shows that the density level of HCHO and VOCs in a classroom was increased after furnishing the classroom. Thus, to measure the quality of air more effectively and accurately, it should be measured after the indoor space are furnished. Newly-built schools are tested for this study. The building sites were investigated to measure and evaluate the IAQ (Indoor Air Quality) in newly-built schools. The result of this study can be used as a basis to improve the environment air condition of the educational facilities.

Design and Implementation of Space Adaptive Autonomous Driving Air Purifying Robot for Green Smart Schools (그린 스마트 스쿨을 위한 공간 적응형 자율주행 공기청정 로봇 설계 및 구현)

  • Oh, Seokju;Lee, Jaehyeong;Lee, Chaegyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.1
    • /
    • pp.77-82
    • /
    • 2022
  • The effect of indoor air pollution on the human body is greater and more dangerous than outdoor air pollution. In general, a person stays indoors for a long time, and in a closed room, pollutants are continuously accumulated and the polluted air is better delivered to the lungs. Especially in the case of young children, it is very sensitive to indoor air and it is fatal. In addition, methods to reduce indoor air pollution, which cannot be ventilated with more frequent indoor activities and continuously increasing external fine dust due to Covid 19, are becoming more important. In order to improve the problems of the existing autonomous driving air purifying robot, this paper divided the map and Upper Confidence bounds applied to Trees(UCT) based algorithm to solve the problem of the autonomous driving robot not sterilizing a specific area or staying in one space continuously, and the problem of children who are vulnerable to indoor air pollution. We propose a space-adaptive autonomous driving air purifying robot for a green smart school that can be improved.

The Spatial Charateristics of Ventilation Efficiency (실내환기효율의 공간적 변화특성에 관한 연구)

  • 김신도;김태식;이희관;이정주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.236-241
    • /
    • 1993
  • Recently, with the ourdoor air pollution, the indoor air pollution devided into living environment and working environment are raised as the problem of indoor space. Also, the more time lived in indoor space, the larger the influence of indoor air pollution. Therefore in this study, the spatial variation of ventilation efficiency was estimated through the experiment using a physical model. The experiment using a physical model. The experiment was conducted in two category; the central zone of ventilated air flow and the corner zone. As the result of experiment, high ventilation efficiency (90$\sim$108%) was shown in the central zone of ventilated air flow. Whereas low ventilation efficiency (46$\sim$77%) was shown in the corner zone. In conclusion, when the designing of ventilation was planned, the zone showed low ventilation efficiency should be considered.

  • PDF

Indoor Air-Conditioning System in building Using Lower Power Wireless Sensor Network (저전력 무선센서 네트워크를 이용한 빌딩 내 환경공조 시스템)

  • Lee, Seung-Chul;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.397-400
    • /
    • 2007
  • Indoor air-conditioning system(IAS) using wireless sensor network serves to reduce the amount of pollution entering the room from outside and also the pollution that is generated indoor. Small-size and lower power wireless sensor node and sensor interface board was designed for indoor air-conditioning system in buildings of offices and industrial establishments. Many sensor nodes forms Ad-hoc network topology using simple forwarding routing to transmit polluting gas concentration data from different rooms to the indoor air-conditioning system. Sensor node analyzes pollution concentration in the each room and air-conditioning system performs to air-distribution and air-inhalation according to room's pollution by regulating the fan of indoor air-conditioning system. To reduce power consumption electrochemical gas sensor was used in the design. Thus the designed system can optimize state of indoor environment. Graphic user interface displays node sate, gas concentration and temperature of each room.

  • PDF

Measurement of Classroom Air Quality in large cities in autumn (가을철 도심지역 학교교사의 실내환경 측정연구)

  • Kim, Yun-Deok;Seo, Dong-Yeon
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.37-42
    • /
    • 2010
  • Together with the concern about the indoor air quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. The law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline. Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to to survey indoor air quality in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, Totally concentration of indoor pollutants were determined in 32 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants(TVOC, float bacteria) exceed the guideline.

Measurement of Classroom Air Quality in large cities in summer (여름철 대도심 학교교실의 실내공기환경 측정연구)

  • Kim, Yun-Deok
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.