• Title/Summary/Keyword: Indoor pollutants

Search Result 327, Processing Time 0.027 seconds

A Study on the Analysis of $CO_2$ Concentration Variation According to the Indoor Space Condition Changes (다양한 실내 환경에서의 $CO_2$ 농도 변화 분석 연구)

  • Ahn, Gwang-Hoon;Kwon, Jong-Won;Kim, Gyu-Sik;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.347-349
    • /
    • 2009
  • Air quality of indoor space environment is affected by various pollutants like as particles and chemical stuffs. The indoor air pollution affects directly the human respiration organs to cause consequently unpleasant mental status. The $CO_2$ concentration level is one of the harmful components of air pollutants. Major factor to increase the $CO_2$ concentration level is the people's breath amount in indoor. The car exhaust gas diffused from the around road also has strong affect on $CO_2$ concentration. There are some other reasons to affect the $CO_2$ concentration change, such as, real-time change of the population movement, closeness to the indoor air flow inlet window and changes in road car traffic amount. A remote monitoring system to measure environmental indoor air pollution concerning on the $CO_2$ concentration was studied and installed realized set-up model. Zigbee network configuration was applied for this system and the $CO_2$ concentration data were collected through USN network. A software program was developed to assure systematic analysis and to display real-time data on web pages. For the experimental test various condition was set up, like as, window opening, stopping air condition operation and adjusting fan heater work, etc. The analysis result showed the relation of various environmental conditions to $CO_2$ concentration changes. The causes to increase $CO_2$ concentration were experimentally defined as windows closing, the stopping air condition system, fan heater operation. To keep the $CO_2$ concentration under the legally required ppm level in public access indoor space, the developed remote measurement system will be usefully applied.

  • PDF

Architectural Implementation of the Indoor Air Quality in the Elementary School Classroom (학교건물의 실내공기환경 개선방안에 관한 건축계획적 연구)

  • Koo, Jae-Oh;Bae, Sun-Chul;Kim, Gon
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.15-22
    • /
    • 2007
  • Indoor air quality(IAQ) problems are not limited to large office buildings that are inadequately operated. In fact, many school buildings have significant potentials of air pollution and indoor air pollutants may be of particular concern because it is estimated that most young students who are physically weak to the pollutants spend about 90% of their time in classrooms. The goal of the study is to provide academic and architectural information on the major factors that influence indoor air quality in the elementary school. In order to gain a better understanding of IAQ problems in schools, a series of measurement studies of indoor air quality were designed and 3 different elementary school buildings located in Chuncheon were selected. The levels of CO, $CO_2$, and total volatile organic compounds(TVOCs) including formaldehyde(HCHO), major concern of this study, were measured in absence of students after class. As the results, it is noticeable that most indoor air pollution comes from sources inside the building, which are, for example, adhesives, upholstery, manufactured wood products, art and scientific supplies. The level of CO was measured similarly to that of outdoors, which means no impact on the indoor air problems since it is lower than the code. Ventilation played an important role in the level of $CO_2$ of which difference was 1.7 times in rough and 230 % of difference in the level was detected among the 3 school buildings. This concludes that indoor air problems might be result of poor building design with inadequate location of corridors within space organization or occupant activity patterns of ventilation.

A Study on the Indoor Air Pollution Level and Its Health Significance in Working and Living Spaces (일부지역의 실내공기오염도와 건강에 미치는 영향에 관한 연구)

  • Shin, Dong-Chun;Lee, Hyo-Min;Kim, Jong-Man;Chung, Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.73-84
    • /
    • 1990
  • The study was carried out to investigate the extent of indoor air pollution in living rooms of apartment houses(residential area) and offices(traffic area A : no smoking space, B : smoking space) in Seoul and to determine the health significance of indoor air pollution. Indoor and outdoor concentrations of major air pollutants were observed simultaneously from February 13 to 17, and July 24 to 28, 1988. The concentrations of carbon monoxide(CO), nitrogen oxides(NOx), sulfur dioxide($SO_2$), carbon dioxide($CO_2$) and total suspended particulate(TSP) in living room and offices were measured and the results were summarized as follows: 1. Both in summer and in winter, the indoor concentrations of CO, $CO_2$, and TSP in offices were higher than the outdoor concentrations, on the other hand, $SO_2$ was higher in the outdoors and NOx was lower than the outdoor concentration only in office A where smoking is not permitted. 2. The indoor and outdoor pollution of offices in winter was significantly higher than that in summer, and the concentrations of CO, NOx and $SO_2$ in indoor and outdoor air in living room in winter were also higher than those in summer. These results suggest that indoor levels of air pollutants are affected by smoking and winter heating systems.

  • PDF

An Analysis on the Actual Condition of Indoor Air Quality in Rural House (농촌지역 노후주택의 실내공기환경 실태분석 연구)

  • Park, Roun;Cho, Sukyeong;Kim, Sangbum
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • The ratio of the deterioration housing in rural area was 29.6%, but it was 18.3% in urban area based on a 2018 survey. In consideration of the point, this study aims to analyze the actual condition of indoor air quality in rural houses to provide basic data for improving the indoor air environment. It was investigated 15housings of Hongseong-gun, Chungchengnam-do. To investigate the correlation between indoor air quality and housing type, both the field survey of housing type and precision diagnosis of concentration of indoor air pollutants such as HCHO, TVOC, Fine dust(PM-10, PM-2.5), CO2, Radon. The results of this study are as follows. First, according to the average value of each element of rural old housing, the construction year was distributed in 1939~2004, and 12households(80%) living in houses older than 30years have passed for about 46years. As for the housing area, more than 12houses(80%) of 60㎡ or more and 3 houses (20%) of less than 60㎡ were often living in relatively small-scale housing. Second, as a result of measuring indoor air pollutants in rural houses, substances exceeding the standard values were found in HCHO, TVOC, CO2. Third, in the case of Fine dust and Radon, none of such factors were exceeded the standard. Fourth, there was no significant difference in indoor air quality depending on housing type in rural houses. This paper is expected to contribute to the regional development projects and effective implementation of rural policies.

A Study on the Air Quality of Indoor Screen Golf in Seoul (수도권 일부지역의 실내 스크린골프장의 공기질 평가)

  • Jo, Ho-Dong;Roh, Jae-Hoon;Kim, Chi-Nyon;Sim, Sang-Hyo;Won, Jong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.192-202
    • /
    • 2010
  • This study aimed to suggest the severity of indoor air pollutants in screen gold arenas which were not sufficiently investigated in Korea up to now and to help users to enjoy golf in more pleasant indoor environment. The indoor environment survey was conducted with 21 screen gold arenas in Seoul from Oct. 28, 2008 to March 13, 2009. Indoor air quality was measured and analyzed in accordance with the Air Pollution Process Test Method specified bu NIOSH(2005). The screen golf arenas are mostly in the underground floors in this study, 4 on the ground floors(19.0%) and 17 in the underground floors(81.0%). In the air in screen golf arenas, the geometric mean of benzene, toluene, ethylbenzene and xylene were 2.92 ${\mu}g/m^3$, 70.34 ${\mu}g/m^3$, 14.00${\mu}g/m^3$ and 31.43 ${\mu}g/m^3$, respectively, which exceeded the exposure limites. Each arena exceeded the exposure limit for one pollutant each. However, styrene didn't exceed the limit as 8.09 ${\mu}g/m^3$. Furthermore, the geometric mean of formaldehyde was 63.11${\mu}g/m^3$ and 7 arenas exceeded the limit. The geometric mean of volatile organic compounds(VOCs) was 428.41${\mu}g/m^3$ and 10 arenas exceeded the limit. For the density distribution of pollutants by location, benzene, toluene, ethylbenzene, xylene, styrene and formaldehyde showed higher density distribution in underground spaces, for which the statistically significant difference was not found. However, PM10 showed the statistically significant difference (p<0.05). In accordance with the analysis on the correlation between the density of pollutants in the screen golf arenas, Pearson correlation coefficient between ethylbenzene and styrene was 0.980, very significant correlation(p<0.01). The correlation coefficients between the density of toluene, ethylbenzene, xylene and styrene and that of VOCs were 0.543, 0.434, 0.451 and 0.459, respectively, which demonstrated the statistically significant difference (p<0.05).

Development of Source Profiles and Estimation of Source Contribution for Hazardous Air Pollutants by the Principal Component Analysis in Indoor Air

  • Kim, Yoon-Shin;Hong, Seoung-Cheol;Lee, Cheol-Min;Kim, Jong-Cheol;Jeon, Hyung-Jin;Song, Kyoung-Min;Roh, Young-Man
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.254-258
    • /
    • 2005
  • The purpose of this study is to characterize the indoor-outdoor relationship of airborne pollutants and recognize probable sources in inside and outside individual apartments in Seoul metropolitan. Simultaneous air monitoring in inside and outside of the 16 Korean Apartments classified into 2groups: less than 1 year old and more than 4 years old from October, 2004 to February, 2005were sampled f3r airborne pollutants(volatile organic compounds, formaldehyde, respiratory particles, carbon dioxide and bacteria) using the Korean Indoor Air Quality Official Method. The concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 in the less than 1 year old apartments were determined to be $773.6{\pm}422.3ppm$, $4,393.8{\pm}2,758.2{\mu}g/m^3$, $98.0{\pm}56.4{\mu}g/m^3$, $254.0{\pm}186.3CFU/m^3$ and $31.7{\pm}14.8{\mu}g/m^3$, respectively, Also, the concentrations of those in the more than 4 years old apartments were determined to be $798.9{\pm}266.5ppm$, $792.7{\pm}398.3{\mu}g/m^3$, $70.0{\pm}30.7{\mu}g/m^3$, $245.6{\pm}122.0CFU/m^3$, $49.7f28.7{\pm}g/m^3$, respectively. The average ratios of the indoor and outdoor concentrations of $CO_2$, TVOCs, HCHO, bacteria and PM10 were 2.2, 3.6, 3.1, 3.9 and 1.4, respectively. These results of this analysis is suggested that $CO_2$, TVOCs, HCHO, bacteria and PM10 in indoor air are both emitted from source within the apartment environment and partly come from outdoor air. With the above considerations in mind, it is suggested that the research for source contribution of indoor air pollutants should be expanded and the detailed interpretation of the results on these needed further study(using principal component analysis(PCA).

  • PDF

The Association of Subjective Symptoms of Students and Indoor Air Quality in Private Academic Facilities (학원시설 실내공기질과 이용자의 자각증상에 관한 연구)

  • Jung, Kyung-Sick;Kim, Nam-Soo;Lee, Jong-Dae;HwangBo, Young;Son, Bu-Soon;Lee, Byung-Kook
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.468-477
    • /
    • 2009
  • To evaluate the current indoor air quality condition of private academic facilities in Korea and investigate its association with subjective symptoms of student residing at the same academic facilities, air quality monitoring was carried out in total of 20 academic facilities located in Seoul, Daejon and Chungnam from the beginning of January to the end of April, 2009. To assess the air quality condition of academic facilities, 6 air pollutants with temperature and humidity were measured simultaneously inside and outside of academic facilities. The rate of exceeding the Indoor Air Quality (IAQ) guideline concentrations in 6 air pollutants were 5%, 85%, 15%, 5%, 10% and 30% for CO, $CO_2$, PM10, HCHO, TVOCs and TBC, respectively. A questionnaire on 16 subjective symptoms related to indoor air quality was given to 342 students who studied at the 20 academic facilities. The most frequent symptom of students was 'I feel easily tired or sleepy', and this was followed by 'I feel muscular pain or stiffness on shoulder, back and neck'. The association of net difference (subjective symptoms at the academic facility - subjective symptoms of the usual situation) with air pollutants was analyzed using spearman rank correlation. In logistic analysis using proportional odds method, the students whose indoor air concentration of HCHO was ${\geq}60{\mu}g/m^3$ hadsignificant odds of having more subjective symptoms of 'My eyes are dry or feel irritated or itching' (OR=5.026: CI=1.587-15.911), 'I feel easily tired or sleepy' (OR=2.956: CI=1.072-8.152), 'I lose my concentration and I feel my memory is falling' (OR=7.745: CI=1.938-30.955) and 'I feel dizzy' (OR=4.424: CI=1.292-15.149) than those of <$60{\mu}g/m^3$.

Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station (서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가)

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Jangwon;Jo, Kyung-Ho;Jung, Eulgyu;Kim, Inkyu;An, Yeonsun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

Plant Growth Responses and Indoor Air Quality Purification in a Wall-typed Botanical Biofiltration System (벽면형 식물바이오필터 내 식물 생육 및 실내공기질 정화)

  • Jung, Seul Ki;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.28 no.5
    • /
    • pp.665-674
    • /
    • 2015
  • The final goal of this research is to develop a botanical biofiltration system, which combines green interior, biofiltering, and automatic irrigation, which can purify indoor air pollutants according to indoor space and the size of biofilter. The biofilter used in this experiment was designed as an integral form of water metering pump, water tank, blower, humidifier, and multi-level planting space in order to be more suitable for indoor space utilization. This study was performed to compare indoor air quality between the space adjacent to a botanical biofilter and the space away from the biofilter (control) without generation of artificial indoor air pollutants, and to evaluate plant growth depending on multiple floors within the biofilter. Each concentration of indoor air pollutants such as TVOCs, monoxide, and dioxide in the space treated with the biofilter was lower than that of control. Dracaena sanderiana ‘Vitoria’ and Epipremnum aureum ‘N Joy’ also showed normal growth responses regardless of multiple floors within the biofilter. Hence, it was confirmed that the wall-typed botanical biofilter suitable for indoor plants was effective for indoor air purification.

Influence on the Indoor Air Quality by Ambient Air during the Summer Season (여름철 실외 공기가 실내 공기질에 미치는 영향)

  • 이학성;강병욱
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.637-644
    • /
    • 1997
  • The purpose of thins study was to quantitatively determine the Indoor Infiltration of pollutants of outdoor origin. The relationship between Indoor and outdoor air is dependent, to a large extent. on the rate of k exchange between these two environments. Mean Indoor/outdoor ratios measured from thins study were: 0.70 for HNO3; 1.60 for HNO2: 0.56 far SOg: 1.30 for mf3: 0.96 for PM2.5(dP<2.5mm: 0.89 for SO4a': 0.87 for NO3· and 0.79 for NH4 'Mean Indoor concentrations for PMa s, SO4a., HNO9, NO3 and NIL' were similar to outdoor levels. Indoor HNO2 and mB3 values were h19her than outdoors. However, the Indoor level of SO2 was lower than ambient level.

  • PDF