• Title/Summary/Keyword: Indoor load

Search Result 260, Processing Time 0.021 seconds

An Analytical Study on the Prediction of Indoor Air Quality and the Reduction of Air Conditioning Load in Bio Safety Level 3 Laboratory (생물안전 3등급시설의 공기환경 예측 및 공조부하 절감에 대한 해석)

  • Hong, Jin Kwan;Park, Hyun Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.813-822
    • /
    • 2012
  • In this study, the multizone simulation for biosafety of BSL3 lab. and energy simulation are carried out simultaneously by using linked model of CONTAM and TRNSYS. In BSL3 lab., annual energy consumption is approximately five to ten times more than the magnitude of the office building. This is because required air change rate is extremely large and it is difficult to maintain room pressure difference efficiently. To maintain pressure difference between laboratory rooms through sealing condition of doors and proper airflow control is significant. In this study, to predict indoor environment of the BSL3 lab.(Influenza A research lab.), the multizone simulation for four kinds of biohazard scenario is also performed as part of risk assessment. Multizone and energy simulation results by using linked model show that these approaches are used as a tool for the energy efficient design and operation method for the safer BSL3 lab. facilities.

A Disaster Evacuation System Using Smart Devices for Indoor Crisis Management in BLE Environments (BLE 환경에서 실내 위기관리를 위한 스마트 장치 기반의 재난대피 시스템)

  • Jang, Minsoo;Jeong, Wooyong;Lim, Kyungshik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.5
    • /
    • pp.281-296
    • /
    • 2015
  • This paper describes a novel disaster evacuation system using embedded systems such as smart devices for crisis and emergency management. In indoor environments deployed with the Bluetooth Low Energy(BLE) beacons, smart devices detect their indoor positions from beacon messages and interact with Map Server(MS) and Route Server(RS) in the Internet over the LTE and/or Wi-Fi functions. The MS and RS generate an optimal path to the nearest emergency exit based on a novel graph generation method for less route computation, called the Disaster Evacuation Graph(DEG), for each smart device. The DEG also enables efficient processing of some constraints in the computation of route, such as load balancing in situation of different capacities of paths or exits. All data interfaces among three system components, the MS, RS, smart devices, have been defined for modular implementation of our disaster evacuation system. Our experimental system has been deployed and tested in our building thoroughly and gives a good evidence that the modular design of the system and a novel approach to compute emergency route based on the DEG is competitive and viable.

A Multiple Access Scheme for Wireless Data Communications in Local Area (근거리 무선 데이터통신을 위한 다중 액세스 기법)

  • 정동근;최종호;전화숙
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.10
    • /
    • pp.1-7
    • /
    • 1992
  • This paper proposes reservation-based multiple access with variable frame length (RMAV) which is a new multiple access scheme for indoor and outdoor wireless data communications. RMAV is based on the slot reservation scheme and adopts a frame structure with variable frame length. The frame length increases as the number of active terminals and/or the system load increases. As a result, RMAV is adapted to the changes in the traffic pattern, and it offers short delay in light load conditions and high throughput in heavy load conditions. The performance of RMAV is evaluated by simulations. In addition, it is compared with the performance of PRMA(packet reservation multiple access).

  • PDF

The Control of Temperature of Green Roof System with the Roof Slab Insulation Method (옥상슬래브 단열조건에 따른 옥상녹화의 열환경 조정효과)

  • Yeo, In-Ae;Cho, Hong-Je;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.869-872
    • /
    • 2008
  • On this study, the Control of Temperature is specified on the view of indoor comfort and building energy consumption. It is estimated by Dynamic heat load simulation which has the factors of insulation method and the soil thickness of the green roof system. The fact that the model which has no insulation has the greatest effect of dropping high temperature and the cooling load decrease is confirmed.

  • PDF

Quantitative Analysis on the Insulating Effect by the Green Roof Planting System (옥상녹화시스템의 식재방식에 따른 단열효과의 정량적 분석)

  • Jang, Hee-Kyong;Cho, Hong-Je;Yeo, In-Ae;Yoon, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.873-876
    • /
    • 2008
  • The purpose of this study was to investigate Green Roof System's thermal performance using dynamic heat load simulation programs related to architectural environment. In results, it is found out that the thermal performance of Green Roof System is stabler than that of roof slab system which means that it is possible to create pleasant indoor environment and save the heating and cooling load.

  • PDF

The optimal window system of office buildings considering energy efficiency (에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구)

  • Yoo, Ho-Chun;Oh, Young-Ho;Park, Seung-Kil
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

Heat Load Estimation-Based Switching Explicit Model Predictive Temperature Control for VRF Systems (시스템 에어컨의 온도 제어를 위한 부하 예측 기반 스위칭 모델 예측 제어)

  • Jun-Yeong Kim;S.M. Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.3
    • /
    • pp.123-130
    • /
    • 2024
  • This paper proposes an EMPC (Explicit Model Predictive Controller) for temperature tracking control based on heat load prediction by an ESO (Extended State Observer) for a variable cooling circulation system with multiple indoor units connected to one outdoor unit. In this system, heat transfer and heat loss relative to the input temperature are modeled using system dynamics. Using this model, we design an EMPC based on an ESO that is robust to temperature changes and depends on airflow. To determine the stability of both the controller and the observer, asymptotic stability is verified through Lyapunov stability analysis. Finally, to validate the performance of the proposed controller, simulations are conducted under three scenarios with varying airflow, set temperature, and heat load.

Fuzzy Control Application Strategy for Energy Saving in HVAC System (공조시스템의 에너지절약을 위한 Fuzzy제어 적용방안 연구)

  • Ahn, Byung-Cheon;Song, Jae-Yeob
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.31-37
    • /
    • 2007
  • The fuzzy control algorithm for HVAC system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with fuzzy control are supply air temperature, chilled water temperature and condenser temperature. This study has been done by using TRNSYS program in order to analyze the HVAC system response. As a result, the fuzzy control algorithm with PID algorithm shows good energy performance in comparison with conventional one.

  • PDF

A Study on the Estimations of the Indoor Natural Temperature in the Underground Space (지중공간(地中空間)의 자연실온(自然室溫) 추정(推定)에 관(關)한 연구(硏究))

  • Lee, Shi Woong;Shon, Jang Yeul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.3
    • /
    • pp.249-256
    • /
    • 1988
  • The purpose of this paper is to research the estimations of the indoor natural temperature in a case of the earth sheltered space and the 1st basement room in comparison with a conventional housing. The result of this study can be summerized as follows: The natural temperature of the earth sheltered house Summer : $${\theta}es=27.0+1.65sin(2{\pi}/24{\cdot}T-1.34)$$ Winter : $${\theta}ew=11.5+1.15sin(2{\pi}/24{\cdot}T-1.61)$$ The natural temperature of the 1st basement space Summer : $${\theta}us=25.5+1.00sin(2{\pi}/24{\cdot}T-1.72)$$ Winter : $${\theta}uw=13.9+1.10sin(2{\pi}/24{\cdot}T-2.29)$$ From the results of the stated above, we can calculate the cooling and heating load in the earth sheltered house and the underground space exactly and easily at Taejeon City.

  • PDF

Detection and Classification of Indoor Environmental gases using Fuzzy ART (Fuzzy ART를 이용한 실내 유해가스의 검출 및 분류)

  • Lee, Jae-Seop;Cho, Jung-Hwan;Jeon, Gi-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.183-186
    • /
    • 2003
  • In this paper, we proposed fuzzy adaptive resonance theory(ART) combined with principle component analysis(PCA) to recognize and classify indoor environmental gases. In experiment Taguchi gas sensors(TGS) are used to detect VOCs. Using thermal modulation of operating temperature of two sensors, we extract patterns of gases from the voltage across the load resistance. We use the PCA algorithm to reduce dimension so it needs less memory and shortens calculation time. Simulation is accomplished to two directions for fuzzy ART with and without PCA.

  • PDF