중앙공조 및 개별공조에서의 외조기 적용 (Application of Four-season Dedicated Outdoor Air Handling Unit in Central and Personal Air-conditioning)

  • 박승태;김영일;이태호;최세영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.591-596
    • /
    • 2008
  • The present study has been conducted to study the performance of dedicated outdoor air handling unit in central and personal air-conditioning. With conventional central and personal air-conditioning systems which are designed according to the maximum load, humidity increase above comfort level can not be avoided as the cooling load decreases. The adoption of dedicated outdoor air handling unit, however, can solve this problem. Moreover, the dedicated outdoor air handling unit has the characteristics of anti-bacteria due to dry coil, energy saving and good indoor air quality. During cooling seasons, dedicated outdoor air handling unit can save energy up to 30% than the conventional cooling+reheating system for controlling both temperature and humidity.

  • PDF

변전소 형태 및 설비규모의 결정 (Application Standards for Substation Types and Facility Scales)

  • 민병욱;신명식;방선웅;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.438-439
    • /
    • 2011
  • Substations in Korea are classified into an outdoor steel structure type, an outdoor GIS(Gas Insulated Switchgear) type, an indoor GIS type, an underground GIS type, and a complex GIS type. Before 1970, substations were built in outdoor steel structure types only. In 1980, an 154kV indoor GIS type substation was built for the first time in Pusan. And the first 345kV indoor GIS type substation, the first 765kV full GIS substation were built in 1984 and in 2002 each. In 1998, 154kV indoor type substations were standardized into regular type and urban type which applied steel frames to structures. In 2002, this was re-standardized into five different types in detail. In 2007, hub substations which had high capacity were built in the region of industrial zone and heavy load areas. And 154kV compact substation was developed and standardized by compacting an indoor GIS type substation in 2009. This paper would present a series of substation type transition and application standards for substation types and facility scales.

  • PDF

여름철 일사를 고려한 투명 투과체 공간의 열환경 특성에 관한 사례연구 (A Case Study on Thermal Performance for Transparent Glazing Space Considering Solar Radiation in Summer)

  • 류영희;서혜수;이민정;남지연;송미나;전정윤
    • KIEAE Journal
    • /
    • 제3권1호
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, buildings with transparent glazing on exterior walls have increased. The transparent glazing on exterior walls gives an impression of opening through introducing external environment's elements to inside of the building, and has various merits and so on, but has defects in controling indoor environments. Especially, the excess of solar radiation in summer increases cooling load causing discomforts to occupants providing radiant environment with high temperature. Cooling load mainly depends on electricity comparing to heating load and intents to centralize specific time. So it is necessary to work out a countermeasure. In this study, showed P building with transparent glazing on exterior walls as a case, investigated indoor thermal performance, numerical analysis of P building in summer through comparing dry-sauna which is represented as radiant environment with high temperature. In the results of this study, transparent glazing space has radiant environment with high temperature such as dry-sauna because of the excess of solar radiation. Accordingly countermeasures are considered in building planning. As concrete methods, there are adiabatic effects using double glazing, use of sunscreen, blind, ventilation facilitation using natural draft, decrease of surface temperature through evaporation cooling and cooling coils.

GHP 난방 모드 운전시 실시간 부하 추정방법에 관한 연구 (A Study on Estimating Real-time Thermal Load During GHP Operation in Heating Mode)

  • 서정아;신영기;오세제;정상덕;지경철;정진희
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.32-37
    • /
    • 2011
  • The present study has been conducted to propose an algorithm regarding real-time load estimation of a gas engine-driven heat pump. In the study, thermal load of an indoor unit is estimated in terms of air-side and refrigerant-side. The air-side estimation is based on a typical heat exchanger model and is found to be in good agreement with experimental data. When it comes to the refrigerant-side load, a pressure difference across a valve must be estimated. For the estimation, it is assumed to be proportional to a bigger pressure difference that is available either by measurement or by estimation. Relative good agreement between the air- and refrigerant-sides suggests that the assumption may be plausible for the load estimation. The summed flow rate of all of indoor units is in good agreement with the throughput of the compressor which are calculated from the manufacturer's software. Accordingly, estimated thermal loads are also in good agreement. The proposed algorithm may be further developed for improved control algorithm and fault diagnosis.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

3실 열펌프의 운전조합에 대한 난방성능 실험연구 (Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units)

  • 김주형;김기영;권영철;박승철
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4197-4203
    • /
    • 2013
  • 본 실험연구는 인버터 압축기를 적용한 실내기 3실을 가진 멀티형 열펌프 시스템의 난방운전 시 열펌프의 난방성능을 연구하였다. 멀티형 열펌프의 운전특성은 항온항습 기능을 가진 공기엔탈피방식의 멀티형 칼로리미터를 이용하여 측정되었다. 난방표준 및 난방저온 온도조건에서 실내기 운전조합에 따른 실험을 수행하여 난방성능 변화를 관찰하였다. 실내기 3실을 가진 열펌프의 실내기 운전조합에 따른 난방표준 및 난방저온 운전에서 난방능력, 난방 COP, P-h선도로부터, 3실을 가진 열펌프의 운전특성과 냉매 사이클의 거동을 조사하였다. 열펌프의 운전부하와 성능은 실내기 조합에 의한 부분부하에 의존하므로 열펌프의 난방능력과 사이클의 거동은 다르게 관찰되었다. 표준온도 시험조건 대비 저온 시험조건의 난방능력과 난방 COP는 감소하였다. 또한 실내기 조합에 대한 냉매사이클은 P-h 선도를 사용하여 분석되었다.

지역냉방 공동주택 적정 냉방부하 산정 (The Estimation of Cooling Load for District Cooling in Apartment Buildings)

  • 김상훈;변운섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.643-649
    • /
    • 2008
  • The purpose of this study is to establish a standard for unit cooling load in central control type apartment applied district cooling. The model of unit household was selected. And the standard of coefficient of overall heat transmission, location of unit household, indoor air temperature, solar radiation & thermal conduction at window and interior load was selected, and region, expansion or non-expansion of balcony, pyeong type, azimuth, rate of window area was applied as parameter. And then cooling load simulation was performed. Based on the result of simulation, the synthetic district cooling load was presented for selecting heat source of apartment applied district cooling, and unit cooling load was analyzed according to design parameter.

  • PDF

온도, 습도, 기류를 이용한 하절기 VRF 시스템의 쾌적 제어 알고리즘 개발 (Development of Comfort Control Logic for VRF System in Summer Season by using 3 Environment Factors(Temperature, Humidity and Air flow))

  • 김종민;최재붕;이상원;조두호;이필호;김영진
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.610-619
    • /
    • 2011
  • This paper investigates the simplified comfort index and control logic for VRF (Variable Refrigerant Flow) system by using 3 environmental factors such as temperature, humidity and air flow. Indoor test under thermal load was conducted to explore relationship of each environment factors that is related to simplified comfort index. Simplified comfort function that has 3 environmental variables was proposed based on survey results. Each factor is measured and comfort preference was surveyed by more than 30 subjects in the indoor comfort test. Moreover, control logic for VRF system was developed and then simulated by using thermal load calculation method and verified with test. The proposed comfort function was in good agreement with survey results, and also verification test trend of comfort change and maintenance are quite similar with survey. Furthermore, through the additional test data analysis some differences of comfort according to position of people staying in the test room were additionally investigated by air flow. People being under an exit of air in the indoor air-conditioner feel more comfortable condition and speed of response to comfort change is relatively fast.

부분부하 조건에서 히트펌프의 운전변수 최적화를 통한 냉방계절성능(SEER) 향상에 관한 실험적 연구 (An Experimental Study on the Performance Improvement of the Seasonal Energy Efficiency Ratio(SEER) of a Heat Pump by Optimizing Operating Parameters under Partial Load Conditions)

  • 최성경;이상헌;김선재;김용찬
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.111-118
    • /
    • 2017
  • Performance factors such as the EER(Energy Efficiency Ratio) and the COP (Coefficient of Performance) are being replaced by seasonal energy efficiency factors, like the SEER (Seasonal EER) and the SCOP (Seasonal COP) to evaluate the performance of a heat pump by the time of the year. Seasonal performance factors, such as the CSPF (Cooling Seasonal Performance Factor) and the HSPF (Heating Seasonal Performance Factor) are used to describe the heat pump's performance during the cool and hot seasons. In this study, the optimization of all heat pump's operating parameters was experimentally conducted to enhance the SEER based on the EU standard (EN 14825). Moreover, the SEER was improved by the compressor frequency, as well as indoor and outdoor fan speeds. In addition, the performance characteristics of the heat pump were studied under partial load conditions. As a result, the SEER was enhanced by 17% when the compressor frequency was optimized. An additional 2% improvement was achievable with the optimization of indoor and outdoor fan speeds.

용량성 부하를 고려한 옥내 전력선 채널 특성 측정 (Measurement of Indoor Power Line Channel Characteristics Considering Capacitive Loads)

  • 허윤석;홍봉화;김철;전계석;이대영
    • 대한전자공학회논문지TC
    • /
    • 제42권6호
    • /
    • pp.53-60
    • /
    • 2005
  • 옥내$\cdot$외의 전력선 환경에 대한 정확한 채널 모델링에 관한 노력이 최근에 이루어지고 있다 알려진 일반 제한과 발표된 모델들은 특별한 형태의 접근들이었다. 본 논문은 더 신속하고 효율적인 전력선 통신 실험을 위한 전력선 채널 특성 측정에 관한 연구이다. 용량성 부하 시뮬레이터는 전력선 옥내 망 모뎀 개발에 필수적인 장비이다. 총 2:H가지 경우의 용량성 부하 변화에 대한 주파수 응답 특성 측정으로 채널 데이터 베이스화를 수행하였다. 본 측정 실험에서 전력선통신 채널은 보다 더 확정적인 매체라는 것을 확인하였다.