• Title/Summary/Keyword: Indoor lighting

Search Result 254, Processing Time 0.022 seconds

A study on a power plant using Dye-sensitized solar cells in low light environments (저조도 환경에서의 염료감응형 태양전지를 활용한 발전소자에 관한 연구)

  • Kim, Sun-Geum;Baek, Sung-June
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.267-272
    • /
    • 2021
  • Recently, attention has been focused on renewable energy and carbon neutrality to resolve fossil energy depletion and environmental problems. In addition, high-rise urban buildings and an increase in building energy are rapidly increasing. There are many restrictions on installing solar power in urban areas. In addition, as buildings become taller, a lot of low-light environments in which shade is formed occur. Therefore, in this study, we intend to develop a power plant capable of generating electric power in an outdoor low-light environment and indoor lighting environment. The power plant in a low-light environment used a dye-sensitized solar cell. A unit cell and a 20cm×20cm module were manufactured, and the electrical characteristics of the power plant were measured using light sources of LED, halogen lamp, and 3-wavelength lamp. The photoelectric conversion efficiency of the unit cell was 17.2%, 1.28%, 19,2% for each LED, halogen lamp, and 3-wavelength lamp, and the photoelectric conversion efficiency of the 20cm×20cm module was 10.9%, 8.7%, and 11.8%, respectively. In addition, the maximum power value of the module was 13.1mW, 15.7 mW, and 14.2 mW for each light source, respectively, confirming the possibility of power generation in a low-light environment

Experiment on Low Light Image Enhancement and Feature Extraction Methods for Rover Exploration in Lunar Permanently Shadowed Region (달 영구음영지역에서 로버 탐사를 위한 저조도 영상강화 및 영상 특징점 추출 성능 실험)

  • Park, Jae-Min;Hong, Sungchul;Shin, Hyu-Soung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.741-749
    • /
    • 2022
  • Major space agencies are planning for the rover-based lunar exploration since water-ice was detected in permanently shadowed regions (PSR). Although sunlight does not directly reach the PSRs, it is expected that reflected sunlight sustains a certain level of low-light environment. In this research, the indoor testbed was made to simulate the PSR's lighting and topological conditions, to which low light enhancement methods (CLAHE, Dehaze, RetinexNet, GLADNet) were applied to restore image brightness and color as well as to investigate their influences on the performance of feature extraction and matching methods (SIFT, SURF, ORB, AKAZE). The experiment results show that GLADNet and Dehaze images in order significantly improve image brightness and color. However, the performance of the feature extraction and matching methods were improved by Dehaze and GLADNet images in order, especially for ORB and AKAZE. Thus, in the lunar exploration, Dehaze is appropriate for building 3D topographic map whereas GLADNet is adequate for geological investigation.

A Research on Autonomous Mobile LiDAR Performance between Lab and Field Environment (자율주행차량 모바일 LiDAR의 실내외 성능 비교 연구)

  • Ji yoon Kim;Bum jin Park;Jisoo Kim
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.4
    • /
    • pp.194-210
    • /
    • 2023
  • LiDAR plays a key role in autonomous vehicles, where it is used to detect the environment in place of the driver's eyes, and its role is expanding. In recent years, there has been a growing need to test the performance of LiDARs installed in autonomous vehicles. Many LiDAR performance tests have been conducted in simulated and indoor(lab) environments, but the number of tests in outdoor(field) and real-world road environments has been minimal. In this study, we compared LiDAR performance under the same conditions lab and field to determine the relationship between lab and field tests and to establish the characteristics and roles of each test environment. The experimental results showed that LiDAR detection performance varies depending on the lighting environment (direct sunlight, led) and the detected object. In particular, the effect of decreasing intensity due to increasing distance and rainfall is greater outdoors, suggesting that both lab and field experiments are necessary when testing LiDAR detection performance on objects. The results of this study are expected to be useful for organizations conducting research on the use of LiDAR sensors and facilities for LiDAR sensors.

Study on the Environmental Factors and Symptoms of VDT Syndrome (VDT 증후군의 환경적 요인과 증상에 대한 연구)

  • Jeong, Seunghui;Lee, Seon Young;Eu, Sun Mi;Kim, Douk-Hoon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2009
  • Purpose: Recently incidence of VDT syndrome has gradually increased as extensive use of computers. VDT syndrome reported by VDT workers include musculoskeletal disorder, neuropsychiatric disoders and eye symptoms such as eye strain, tired eyes, irritation and blurred vision. The environmental factors of VDT syndrome include electromagnetic waves, size, brightness and lighting of computer screen, height of a monitor and a worktable, working hours, kind of task, distance between screen and workers, indoor humidity and temperature, indoor air contamination and ventilation. In this study, we investigated the environmental factors related to body symptoms and health effects included in VDT syndrome. Methods: Study subjects were total 120 persons (54 male, 66 female) with age from 19 to 28. We surveyed the body symptoms and physical discomfort when doing an activity in a short distance such as reading book or paper, computer work. The questionnaire included main body symptoms, self-consciousness symptoms of eye, satisfaction of working environment, pain of the wrist when using keyboard and mouse. Results: Most of people (70%) felt physical pain from long time work of computer, paper, electrical apparatus. They mainly complained pain of neck and low back (57.1%), eye (45.2%) and head (31%). With the environmental factors, 78.3% of the subjects complaint pain of eye from inappropriate illumination. Most of the symptoms included 'eye fatigue'(38.3%), 'dryness of eye'(31.9%) and 'blurred vision'(23.7%). Subjects in this study complained discomfort of their chairs and most of them experienced pain in the wrist when using keyboard or mouse. Conclusions: When people use electrical apparatus or work with paper, people would get their eye fatigue and feeling of physical fatigue because of not harmonizing various environmental factors such as light, space, posture, worktable with theirselves. Therefore, workers should develop preventive method such as self-control of adequate break time to avoid fatigue while VDT work. Work environment should be changed to ergonomic design for optimal visual environment to prevent musculoskeletal disorder through constant research.

  • PDF