• 제목/요약/키워드: Indoor inhalation

검색결과 52건 처리시간 0.018초

토양오염 우려기준과 토양 자연배경농도에 대한 위해성평가 (Risk assessment for Soil Contamination Warning Standard and Soil Background Concentration)

  • 신동;박성재;조영태;봉재은;박정훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제26권3호
    • /
    • pp.37-49
    • /
    • 2021
  • There is domestic Soil Contamination Warning Standard (SCWS) as remediation standard concentration of contaminated soils. No risk should be observed at soil concentration less than SCWS. Therefore, SCWS was evaluated to confirm the risk assessment. Background Concentration of Soil (BGC) and target remediation concentration were also assessed. The results show that Excess Cancer Risk (ECR) of SCWS was the highest in the groundwater intake pathway (Adult: 6.27E-04, Child: 2.81E-04). Total Cancer Risk (TCR) was 7.76E-04 and 4.30E-04 for adult and child, exceeding reference value (10-6). Hazard Quotient (Non-Carcinogenic Risk, HQ) was the highest in the indoor air inhalation pathway (Adult: 3.64E+03, Child: 8.74E+02). Hazard Index (Total Non-Carcinogenic Risk, HI) exceeded reference value 1. ECR of the BGC was the highest in the groundwater intake pathway (Adult: 1.71E-04, Child: 7.67E-05). TCR was 2.12E-04 for adults and 1.17E-04 for children, exceeding the reference value (10-6). HQ was the highest in groundwater intake pathway (Adult: 4.10E-01, Child: 1.84E-01). HI was lower than reference value 1 (Adult: 4.78E-01, Child: 2.50E-01). The heavy metal affecting ECR was Arsenic (As). The remediation-concentration of As was 7.14 mg/kg which is higher than BGC (6.83 mg/kg). TCR of As should be less than reference value (10-6), but it was higher for all of SCWS, BGC and target remediation concentration. Therefore, it is suggested that risk assessment factors should be re-evaluated to fit domestic environmental settings and SCWS should be induced to satisfy the risk assessment.

소음영 진폐증 환자에서의 등기류용량(Volume of Isoflow)의 변화 (Change of Volume of Isoflow in Pneumoconiosis Patients with Small Opacity)

  • 오상용;김지원;정장영;김경아;윤임중
    • Tuberculosis and Respiratory Diseases
    • /
    • 제40권5호
    • /
    • pp.540-547
    • /
    • 1993
  • 연구배경 : 통상적인 폐기능 검사에 이상이 없는 초기단계의 단순 진폐증 환자들에서 세소기관지의 기능장애를 조기발견하는데 유용한 방법으로 알려진 등기류용량을 측정하여 분진작업에 기인한 세소기도 장해 여부를 알아보고 진폐증 환자들을 조기 관리하는데 등기류용량 측정의 적용에 대한 타당성 여부를 알아보고자 하였다. 방법 : FEV1 80% 이상, FEV1/FVC 75% 이상인 분진폭로군 67명과 분진폭로력이 없는 20명을 대상으로 실내 공기 흡입 및 80% Helium과 20% 산소의 혼합가스 흡입 후 측정한 각각의 최대호출기류량곡선(maximal expiratory flow volume cuve)에서 ${\Delta}V_{max50},\;{\Delta}V_{max75},\;V_{iso}V/VC$을 구하여 진폐증 category 별로 대조군과 비교하였다. 결과: 1) 대조군에 비하여 전체 분진폭로군에서 ${\Delta}V_{max50}$${\Delta}V_{max75}$은 유의한 차이가 없었지만 $V_{iso}V/VC$은 현저하게 (p<0.01)증가되어 $V_{iso}V/VC$이 세소기도의 기능장해를 조기발견하는데 가장 유용한 지수임을 알 수 있었다. 2) 비흡연자를 포함한 분진폭로군과 흡연자만으로 이루어진 분진폭로군에서 $V_{iso}V/VC$의 분석결과가 매우 상이한 것으로 보아 흡연이 세소기관지병변을 초래하는데 중요한 요인으로 작용하였다. 4) 분진폭로군에서 흉부방사선사진상 진폐음의 조밀도가 증가함에 따라 $V_{iso}V/VC$이 증가되었으나 각각의 categry에서는 서로간에 유의한 차이가 없어 진폐음영의 조밀도와 세소기도 장해와는 유의한 연관성이 없었다. 4) 분진작업에 종사한 근무 기간과 $V_{iso}V/VC$의 증가와는 유의한 연관성이 없었다. 결론 : 단순진폐중 환자들에서 통상적인 폐기능검사에 이상소견이 없는 경우 등기류용량($V_{iso}V/VC$)을 측정하여 세소기도의 기능장애를 파악함으로써 진폐증의 조기관리에 도움이 될것으로 생각된다.

  • PDF