• 제목/요약/키워드: Indoor environmental factors

검색결과 293건 처리시간 0.025초

실내 환경 중 알데하이드 농도 분포 및 영향 요인 평가 (Factors Related to Aldehydes Exposure and Symptoms in Residential Indoor Air)

  • 양지연;이지호;임영욱;박성은;홍천수;김창수;신동천
    • Environmental Analysis Health and Toxicology
    • /
    • 제22권1호
    • /
    • pp.37-47
    • /
    • 2007
  • Aldehydes are irritants of the upper respiratory tract with symptoms such as eye, nose, and throat. Formaldehyde classified in Group 2A by the International Agency for Research on Cancer and a probable human carcinogen by the Unite States Environmental Protection Agency due to its carcinogenicity. Aldehydes may be emitted from many other consumer products, such as permanent press fabrics, cosmetics, fiberglass insulation, paints, and coatings. The purpose of this study was to examine the does-response relationship between aldehydes levels and symptoms (eyes, nose, throat, and respiratory) for 36 dwellings and 280 households in Korea. As a result, environmental factors affecting aldehydes level were indoor smoking, ventilation, using of carpet, bed, and new furniture, painting for renovation, and indoor humidity. There wat weakly positive correlation between symptom score and aldehydes level.

사무소 리모델링의 실내환경요소에 대한 선호도 분석 -수요자와 공급자 측면 비교를 중심으로- (An Analysis for Recognizing the priority of Indoor Environmental Factors in office Remodeling)

  • 최진혁;박태은;이정복;김소연;이경회
    • KIEAE Journal
    • /
    • 제2권4호
    • /
    • pp.57-64
    • /
    • 2002
  • Nowadays the importance of Building Remodeling as a means to create an architectural environment capable of responding to the social, economic changes has increased more than before. After long time pass, the aged building have faced the need for the overall repair of the structure and function. Remodeling is much more saving the time and cost than new construction in the office building. This study was focused in functional and efficient evaluation. Based on these points, we developed the evaluation factors, and verified a validity of evaluation factors through a survey. The purpose of this study was focused on the Analysis for Recognizing the priority of Indoor Environmental Factors in office Remodeling. This study provides us the competitive guidance of remodeling. The owners and tenants take the maximum efficiency with the minimum cost.

국내 일부학교 건축물의 실내공기질 평가 (The Assessment of Survey on the Indoor Air Quality at Schools in Korea)

  • 손종렬;노영만;손부순
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.140-148
    • /
    • 2006
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the health effects related to indoor air pollution. Therefore, this study was performed to investigate the characteristics of IAQ in 55 kindergartens, elementary school, middle schools, and high schools from June, 2004 to May, 2005 in Korea. We measured indoor air pollutants($PM_{10},\;CO_2$, HCHO, total bacteria colony(TBC), CO, radon, TVOCs, asbestos, and $O_3$), and physical factors(noise, temperature, relative humidity, and illumination) with necessary of management for IAQ in school. We classified into 5 kinds of the school by period since building completion, <1 year, 1-3 years, 3-5 years, and 5-10 years. The concentration of pollutants and the level of physical factors compared with standards and guidelines of IAQ on the Ministry of Environment, the Ministry of Health and Welfare, and the Ministry of Education and Human Resources Development. The major results obtained from this study were as follows. Temperature, relative humidity and illumination among the physical factors did not exceed the standards, but noise exceeded it. Asbestos and $O_3$ did not detect in surveyed classrooms. CO, TBC, TVOCs, and HCHO in kindergartens, TBC in elementary schools, TBC, TVOCs dnd HCHO in middle schools, and HCHO in high schools detected the standards. This study is conducted as a part of efforts to provide a foundational data for further relative researches on management of IAQ of school. Therefore, we suggest that country plan for management of IAQ in school should be established through long-term and continuous investigation for assessment on IAQ in school and health risk assessment for students.

외피 유형별 석재 모형돔의 동절기 환경 특성에 관한 연구 (A study on the characteristics of environmental factors of granite dome models with different envelope structures in winter)

  • 공성훈
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.642-646
    • /
    • 1999
  • Factors governing the rate of heat exchange comprise the air temperature, the speed of air movement, relative humidity, and relation indoors. Recently, there are many researches on the transient analysis of indoor environmental factors such as the dry bulb temperature, relative humidity and air velocity in miniature models. The purpose of this study is to measure the environmental factors and to analyze and evaluate the characteristics of indoor environment with the different envelope structures using a granite dome model. According to the variation of humidity, the state of interior relative humidity for clay model has an equal tendency, although a little range of variation is shown in comparison to the cement model.

  • PDF

실내오염물질의 환기기술전략에 따른 영향평가 : 수치적 모델을 이용한 HVAC 시스템의 비교연구 (The Impact of Ventilation Strategies on Indoor Air Pollution: A Comparative Study of HVAC Systems Using a Numerical Model)

  • Park, Sung-Woo;Song, Dong-Woong;D.J. Moschandreas
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제11권E호
    • /
    • pp.45-54
    • /
    • 1995
  • Indoor air quality models are useful to predict indoor air pollutant concentrations as a function of several indoor factors. Indoor air quality model was developed to evaluate the pollutant removal efficiency of variable-air-volume/bypass filtration system (VAV/BPFS) compared with the conventional variable-air-volume (VAV) system. This model provides relative pollutant removal effectiveness of VAV/BPFS by concentration ratio between the conventional VAV system and VAV/BPFS. The predictions agree closely, from 5 to 10 percent, with the measured values for each energy load. As a results, we recommend the VAV/BPFS is a promising alternative to conventional VAV system because it is capable of reducing indoor air pollutant concentration and maintaining good indoor air quality.

  • PDF

도시 일부지역에서의 실내 라돈농도에 관한 연구 (A Study on Indoor Radon Concentrations in Urban Area)

  • 김순애;백남원
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.

대전광역시 내 실내공기질 취약 가구의 환경성질환 연관 알레르기 혈액검사 시행 효과 (Blood Test for Allergies Related to Environmental Diseases in Households Vulnerable to Indoor Air Quality in Daejeon Metropolitan City)

  • 서희원;오지혜;백승화;황석연
    • 한국환경보건학회지
    • /
    • 제50권4호
    • /
    • pp.291-301
    • /
    • 2024
  • Background: Based on rapid industrial development, environmental pollution has emerged as a social problem and exposure to environmental diseases is increasing. The number of patients suffering environmental diseases in Daejeon Metropolitan City is also steadily increasing, and the prevalence of atopic dermatitis there is the highest in the country. Objectives: In order to minimize exposure to harmful factors for the prevention and management of environmental diseases, an environmental disease management system suitable for the environmental characteristics of each region is needed. Basic preliminary research should be conducted to identify environmental hazards in Daejeon Metropolitan City and establish a management system. Methods: Among the households (about 50 people) participating in the 2022 Indoor Environment Remote Measurement (IoT) program, households (children aged 5 or older and adults) with insufficient results for indoor air quality measurement and symptoms related to environmental diseases were selected. The subjects were tested for living conditions, blood tests, biomarker analysis (immunoglobulin E, Eosinophil count, histamine) and multiple allergy antigen tests (MAST, 93 types). Results: Participants were 53.7% female and 46.3% male, and the average age showed an even age distribution. IgE and eosinophil count were positively correlated, and significant results were found for atopic dermatitis and IgE (p<0.05). Typical risk factors observed in the survey was the amount of indoor ventilation, chemical exposure, heredity, house dust mites, fungi, and food. Conclusions: The purpose of this study was to help establish a regional management system for environmental diseases, research and diagnosis of environmental diseases. This study is meaningful in that it is a study with customized consulting suitable for the environment of Daejeon Metropolitan City. If the limitations are addressed and continuous research is conducted, it will be helpful for the management, diagnosis, and research of environmental diseases.

신축 주택의 톨루엔 발생량 모델을 이용한 건강위해성 평가 (Risk Assessment by Toluene Source Emission Model in Indoor Environments of New Houses)

  • 김영희;양원호;손부순
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.398-403
    • /
    • 2006
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Understanding the effectiveness of indoor air quality control depends on knowledge of the characteristics of air pollutants in indoor air, especially their quantities and persistence, and the relevance of indoor sources to these factors. Toluene within new and established houses has been determined and factors significant to its presence have been identified. A total of 30 selected houses in Seoul, Asan and Daegu areas that were constructed within 4 years and over 4 years of construction were measured the concentration of toluene from July to September in 2004. Toluene emission decay of double-exponential model exhibited good fit of $Y=276.37e^{-1.21x}(R^{2}=0.34,\;P=0.06)$ for 2 years and then $Y=51.54e^{-0.11x}(R^{2}=0.40,\;P=0.0)$ from 23 years in new houses. In case of living in new houses, noncarcinogenic health effects of exposure to toluene was 1.38 of hazard quotient (HQ) comparing to toluene reference dose of 0.13 mg/kg-day.

가정 내 부유 진균의 농도와 관련 요인 (Airborne Fungi Concentrations and Related Factors in the Home)

  • 조용민;류승훈;최민석;서성철;정지태;최재욱
    • 한국환경보건학회지
    • /
    • 제39권5호
    • /
    • pp.438-446
    • /
    • 2013
  • Objectives: This study was performed in order to determine airborne fungi levels in homes and find related factors that may affect airborne fungi concentration. Methods: Fifty homes were study subjects for measuring airborne fungi. For sampling airborne fungi, the impaction method on agar plates was used and samples were counted as colony forming units per cubic meter of air ($CFU/m^3$). In addition, information regarding housing characteristics and atopic disease in each home were collected via questionnaire. Results: The geometric means (GM) of airborne fungi concentrations in fifty living rooms and bedrooms were 68.03 and 62.93 $CFU/m^3$, respectively. The GM of airborne fungi concentration in atopy homes was 78.42 $CFU/m^3$. This was higher than non-atopy homes' 54.34 $CFU/m^3$ (p-value=0.051). In the results of the multiple regression analysis, outdoor airborne fungal concentration proved a strong effective factor on indoor airborne fungal concentration. Also, construction year, floor area of house, indoor smoking and frequency of ventilation were factors that showed a significant association with indoor airborne fungi concentration. Conclusions: The results of this study show that some housing and living characteristics may affect the development and increase of airborne fungi. In addition, exposure to airborne fungi may be a risk factor for the prevalence of childhood atopic diseases.

실내환경조절 측면에서 본 석굴암(石窟庵) 평가에 관한 연구 (A Study on the Valuation of Seoggur - Am from the Viewpoint of Indoor Environment Control)

  • 최영식
    • 한국산업융합학회 논문집
    • /
    • 제1권2호
    • /
    • pp.21-30
    • /
    • 1998
  • It is very important that we try to keep our traditional historical assets in the original form for a long time. Seoggur-Am has a very long and old history of about 1200 years. Yet, for the past several years there are many factors ruinning this historical treasure. Recently, specialist are new scientifically examining Seoggur-Am and evaluating its current condition, If you only judge these historical assets from the exterior structural environmental approach your scientific conclusion will not be complete. No one has studied Seoggur-Am from the viewpoint of indoor environmental climate. Therefore, I have surveyed and prepared a report of investigation as well as countermeasure so to understand the impact of indoor environmental climate on Seoggur-Am. The purpose of this paper is to first survey the existing research data based on exterior structural environment. Secondly, closely evaluate the new data of Seoggur-Am from the viewpoint of indoor environmental climate.

  • PDF