• Title/Summary/Keyword: Indoor environmental

검색결과 1,569건 처리시간 0.036초

보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가 (Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors)

  • 이보람;이대엽;반현경;이세원;김규상;이기영
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

공기청정기의 일부 실내공기 오염물질 제거효율에 관한 연구 (Efficiency of Removal for Indoor air pollutants by Air Cleaners in the Indoor Environments)

  • 이태형;김윤신;홍승철;이철민;김종철;전형진;김중호
    • 한국환경과학회지
    • /
    • 제14권5호
    • /
    • pp.491-497
    • /
    • 2005
  • In this study, we investigated $PM_{10},\;NO_2$, and l-hydroxypyrene(1-OHP) in urine at indoor environments which are 35 houses and 20 hospitals for using air cleaner and non-using air cleaner in Seoul metropolitan area and Kyoung-gi province from April, 2003 to February, 2004. Moreover, we examined effect of improvement for indoor air quality and health effect by concentration of 1-OHP also we investigated removal efficiency by air cleaner for $PM_{10},\;NO_2$, and 1-OHP that were 28.5\%,\;27.4\%,\;and\;42.1\%$ respectively. Concentration of$PM_{10},\;NO_2$, and 1-OHP were $19.02\pm18.14{\mu}g/m^3,\;8.66\pm3.06ppb,\;and\;0.19\pm0.18{\mu}g/g$, creatinine when air cleaner was no worked. The concentration for $PM_{10},\;NO_2$. and 1-OHP were $13.60\pm10.79{\mu}g/m^3,\; 6.29\pm2.71ppb,\;and\;0.11\pm0.10{\mu}g/g$ creatinine, respectively. It was significant statistically. Therefore, it is considered using the air cleaner to remove the partial pollutants in indoor environment and is positive effect for health.

국내 주택에서 물 피해 유형에 따른 부유곰팡이 농도 수준 평가 및 동정 분석 (Assessment of the level and identification of airborne molds by the type of water damage in housing in Korea)

  • 이주영;황은설;이정섭;권명희;정현미;서성철
    • 실내환경 및 냄새 학회지
    • /
    • 제17권4호
    • /
    • pp.355-361
    • /
    • 2018
  • Mold grows more easily when humidity is higher in indoor spaces, and as such is found more often on wetted areas in housing such as walls, toilets, kitchens, and poorly managed spaces. However, there have been few studies that have specifically assessed the level of mold in the indoor spaces of water-damaged housing in the Republic of Korea. We investigated the levels of airborne mold according to the characteristics of water damage types and explored the correlation between the distribution of mold genera and the characteristics of households. Samplings were performed from January 2016 to June 2018 in 97 housing units with water leakage or condensation, or a history of flooding, and in 61 general housing units in the metropolitan and Busan area, respectively. Airborne mold was collected on MEA (Malt extract agar) at flow rate of 100 L/min for 1 min. After collection, the samples were incubated at $25^{\circ}C$ for 120 hours. The cultured samples were counted and corrected using a positive hole conversion table. The samples were then analyzed by single colony culture, DNA extraction, gene amplification, and sequencing. By type of housing, concentrations of airborne mold were highest in flooded housing, followed by water-leaked or highly condensed housings, and then general housing. In more than 50% of water-damaged housing, the level of airborne mold exceeded the guideline of Korea's Ministry of Environment ($500CFU/m^3$). Of particular concern was the fact that the I/O ratio of water-damaged housing was greater than 1, which could indicate that mold damage may occur indoors. The distribution patterns of the fungal species were as follows: Penicillium spp., Cladosporium spp. (14%), Aspergillus spp. (13%) and Alternaria spp. (3%), but significant differences of their levels in indoor spaces were not found. Our findings indicate that high levels of mold damage were found in housing with water damage, and Aspergillus flavus and Penicillium brevicompactum were more dominant in housing with high water activity. Comprehensive management of flooded or water-damaged housing is necessary to reduce fungal exposure.

비 포괄적인 금연정책을 시행한 호프집의 면적에 따른 실내 PM2.5 농도 (Indoor PM2.5 Concentrations in Different Sizes of Pubs with Non-comprehensive Smoke-free Regulation)

  • 김정훈;임채윤;이대엽;김혜진;곽수영;이나은;김상환;하권철;이기영
    • 한국환경보건학회지
    • /
    • 제41권2호
    • /
    • pp.126-132
    • /
    • 2015
  • Objectives: The Korean government implemented a smoke-free regulation for pubs with a net indoor area of ${\geq}100m^2$ on January 1, 2014. The purpose of this study was to determine the indoor levels of concentrations of particulate matter smaller than $2.5{\mu}m$ ($PM_{2.5}$) in implemented and non-implemented pubs in Seoul and Changwon. Methods: $PM_{2.5}$ concentrations in fifty-two $100-150m^2$ (implemented) and fifty-seven < $100m^2$ (non-implemented) pubs were measured. A real-time aerosol monitor was used to measure $PM_{2.5}$ concentrations. Field technicians recorded characteristics of the pubs including net indoor area, indoor volume and presence of smoking rooms and counted the number of burning cigarettes, patrons and vents. Results: Differences between indoor and outdoor $PM_{2.5}$ concentrations in $100-150m^2$ and < $100m^2$ pubs were not significantly different in each city. Smoking was observed in 33% of $100-150m^2$ pubs and 51% of < $100m^2$ pubs. Average differences between indoor and outdoor $PM_{2.5}$ concentrations in the $100-150m^2$ and < $100m^2$ pubs were $79.2{\mu}g/m^3$ and $155.6{\mu}g/m^3$, respectively. When smokers were not observed, differences between indoor and outdoor $PM_{2.5}$ concentrations ware $12.4{\mu}g/m^3$ in $100-150m^2$ pubs and $24.5{\mu}g/m^3$ in < $100m^2$ pubs. Conclusion: Although the regulation was implemented only in ${\geq}100m^2$ pubs, a higher difference between indoor and outdoor $PM_{2.5}$ concentrations was observed in implemented and non-implemented pubs with smokers. Strict implementation of the regulation in all pubs is needed for better indoor air quality.

실내체육관에서의 공기오염에 관한 연구 (A Study on Air Pollution in Indoor Gymnasiums)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

신축건물 사무실내 식물 적용의 실내 공기질 및 재실자 건강영향 평가 - 알레르기 비결막염 및 스트레스 관련 증상설문을 중심으로 - (Impact of Indoor Plants on Indoor Air Quality and Occupational Health in Newly Built Public Building Offices - Focusing on Allergic Conjunctivitis and Stress-related Symptom Questionnaires -)

  • 이용원;임영욱;김광진;김호현
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.334-348
    • /
    • 2017
  • Objectives: We investigated the impacts of indoor plants on indoor air quality and occupational health, focusing on allergic rhinconjunctivitis and stress among employees in new office buildings. Methods: A total of 34 employees working at new public office buildings were enrolled as subjects (n=17, with indoor plants) and as a control (n=17) group. Before and after introducing indoor plants for three months, indoor air quality measurements including VOCs and aldehydes and questionnaires on sick building syndrome, AR symptoms (ARIA based), stress (DASS 42, KOSS, and SACL), and indoor characteristics were performed and statistically analysed. Results: Among the 34 enrolled subjects, 19 were included in the probable AR subject group (subjects with indoor plants, n=8, control n=11) and completed all questionnaires. Statistical analyses were done for total, AR subject groups, and controls. As a result, it was confirmed that major indoor air pollutants decreased after the introduction of indoor plants (p<0.5). Among major symptoms of allergic rhinoconjunctivitis, watery rhinorrhea, nasal stuffiness, and nasal itching indexes decreased (p<0.5, respectively). A decrease was noted in some areas of work-related stress indexes (mainly KOSS) among the subject group (total and AR) and a decrease of indoor environmental attractiveness among the control group (total and AR) (p<0.5, for all). Conclusions: Indoor plants may help reduce indoor air pollutants and decrease AR symptoms and work-related stress of employees in newly built office buildings. Various further follow-up studies on the mechanism of environmental, physical, and emotional influences and utilization of indoor plants in association with allergic diseases will be needed.

공동주택 내의 기계환기 설비에 따른 라돈농도 평가 (Evaluation of Radon Concentration according to Mechanical Ventilation Systems in Apartments)

  • 최지원;홍형진;이정섭;유주희;박보람;김가현;윤성원;이철민
    • 한국환경보건학회지
    • /
    • 제47권4호
    • /
    • pp.330-338
    • /
    • 2021
  • Background: This study was conducted to provide background information for the proper management of radon contamination in apartments using mechanical ventilation facilities in residential environments. Objectives: To this end, this study compared and evaluated changes in radon concentrations based on different operating intensities of mechanical ventilation with or without natural ventilation. Methods: For the continuous measurement of radon concentrations, an RAD7 instrument was installed in four apartments equipped with a ventilation system. The measurements were done for comparison of ventilation types and different ventilation intensities ("high", "middle", "low"). Results: The results confirmed that both mechanical and natural ventilation sufficiently reduced the radon concentration in the apartments. In particular, mechanical ventilation at "high" intensity was the most effective. Natural ventilation combined with mechanical ventilation and then natural ventilation alone were the second and the third most effective, respectively. Conclusions: When using ventilation to reduce indoor radon concentrations, it is most effective to operate mechanical ventilation ("high") or natural ventilation and mechanical ventilation at the same time. In cases where mechanical ventilation is available alone, it is recommended to operate it at a minimum of "middle" intensity.

박물관 실내공기질 변동에 관한 연구 (Variation of Indoor Air Quality in Museum)

  • 이정주;김신도;부문자
    • 한국환경보건학회지
    • /
    • 제22권4호
    • /
    • pp.43-48
    • /
    • 1996
  • Indoor air quality(IAQ) in museum is very important for protection of cultural properties. In our study, we measured air pollutants($NO_x, NH_3, SO_2, O_3$, CO, $CO_2$, TSP), temperature and humidity to evaluate IAQ of national central museum. Indoor carbon dioxide and TSP concentrations were higher than outdoor concentrations. Temperature, huinidity and TSP had large deviation depending on air conditioning operates or not. Indoor gas phase pollutants except $CO_2$ were lower than outdoor concentrations, but $SO_2$ concentration was high in storage. $CO_2$ and TSP were influenced by the number of spectators.

  • PDF

신축공동주택의 실내공기질 특성 및 평가 -휘발성 유기화합물 및 포름알데히드 중심으로- (Characterization and Assessment of Indoor Air Quality in Newly Constructed Apartments -Volatile Organic Compounds and Formaldehyde-)

  • 심상효;김윤신
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.275-281
    • /
    • 2006
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. Especially exposure to indoor air can potentially pose a greater threat than exposure to ambient air when indoor environments have sources of contaminants. In this study, volatile organic compounds (VOCs) and formaldehyde (HCHO) within newly constructed apartment have been determined in 27 houses of apartment in Seoul from December 2004 to March 2005. The measured indoor air pollutants were HCHO, volatile organic compounds including benzene, toluene, styrene, xylene, ethylbenzene and sampled on the standard method of Ministry of Environment in Korea. The indoor levels for benzene, xylene, toluene, ethylbenzene, styrene, and HCHO have significant increase trend after 5 hours closing of windows and doors. Levels of measured air pollutants concentrations between living rooms and bedrooms have not shown significant difference. Spearman correlation coefficient among the measured air pollutants ranged from 0.303 to 0.946, indicating similar source in building materials.

서울시의 대중교통수단내 실내공기질에 대한 연구 (An Investigation of Indoor Air Quality of Public Transportation System in Seoul City)

  • 김윤신;홍승철;전준민
    • 한국환경보건학회지
    • /
    • 제20권1호
    • /
    • pp.28-38
    • /
    • 1994
  • The objective of this study were to measure concentrations of indoor pollutants in public transportation systems to provide importance of indoor air quality in transportation systems to policy makers. Indoor air quality of the pollutants (CO, CO$_2$, PM-10) and environmental sources (temperature, humidity) were measured at subway, seat-type bus, and city-type bus in the Seoul area from April to September 1992. The same pollutants and environmental sources were also measured at selected bus stops and subway stations during October 1991-September 1992. The mean concentrations of indoor pollutants in the public transportation systems were showed 115.5 $\mu$g/m$^3$ in PM-10, 6.8 ppm in CO, and 2167.9 ppm in CO$_2$, respectively. The mean values of PM-10 and CO showed below the U.S. 24 hour standard value of PM-10 and the Korea ambient CO standard, while the mean concentrations of CO$_2$ exceeded the Korea CO$_2$ standard. The highest levels of indoor concentration at public transportation systems were PM-10 of 134.6 $\mu$g/m$^3$ in the subway, CO of 8.9 ppm in the city-type bus, CO$_2$ of 2,511.1ppm in seat-type bus, respectively. The results showed that indoor air quality in bus and subway seemed likely to be affected by number of passengers and outdoor air infiltrated from exhausted gases of automobiles.

  • PDF