• Title/Summary/Keyword: Indoor air environment

Search Result 1,058, Processing Time 0.032 seconds

Experimental Study on the Characteristics of Ground Heat Exchange in Heating Greenhouses (난방 온실의 지중열 교환 특성에 관한 실험적 연구)

  • Shin, Hyun-Ho;Nam, Sang-Woon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.3
    • /
    • pp.218-223
    • /
    • 2016
  • The calculation method of ground heat exchange in greenhouses has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the soil temperature distribution and the soil heat flux in three plastic greenhouses of different size and location during the heating period. And then the calculation methods of ground heat exchange in greenhouses were reviewed. The soil temperature distributions measured in the heating greenhouse were compared with the indoor air temperature, the results showed that soil temperatures were higher than room temperature in the central part of greenhouse, and soil temperatures were lower than room temperature in the side edge of greenhouse. Therefore, it is determined that the ground heat gain in the central part of greenhouse and the perimeter heat loss in the side edge of greenhouse are occurred, there is a difference depending on the size of greenhouse. Introducing the concept of heat loss through the perimeter of building and modified to reflect the size of greenhouse, the calculation method of ground heat exchange in greenhouses is considered appropriate. It was confirmed that the floor heat loss measured by using soil heat flux sensors increased linearly in proportion to the temperature difference between indoor and outdoor. We derived the reference temperature difference which change the direction of ground heat flow and the perimeter heat loss factor from the measured heat flux results. In the heating design of domestic greenhouses, reference temperature differences are proposed to apply $12.5{\sim}15^{\circ}C$ in small greenhouses and around $10^{\circ}C$ in large greenhouses. Perimeter heat loss factors are proposed to apply $2.5{\sim}5.0W{\cdot}m^{-1}{\cdot}K^{-1}$ in small greenhouses and $7.5{\sim}10W{\cdot}m^{-1}{\cdot}K^{-1}$ in large greenhouses as design standard data.

DEHP, DEP and DBP Exposure Analysis using Urinary Metabolites of Gyonggi Province University Students

  • Lee, JangWoo;Kho, YoungLim;Kim, SungKyoon;Choi, Kyungho;Hwang, SeongHee;Jeong, Jeeyeon;Kim, Pangyi
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.5
    • /
    • pp.408-417
    • /
    • 2013
  • Objectives: Phthalates are used as plasticizers in polyvinyl chloride (PVC) plastics. As phthalate plasticizers are not chemically bound to the PVC, they can leach, migrate or evaporate into indoor air and atmosphere, foodstuffs, other materials, etc. Therefore, humans are exposed through ingestion, inhalation, and dermal exposure over their entire lifetime, including during intrauterine development. In particular, university students have a great number of opportunities to contact products including phthalates during campus life (food packaging, body care products, cosmetic, lotions, aftershave, perfume etc.). The purpose of this study was to examine levels of phthalate exposure as undergraduate students begin to use pharmaceuticals and personal care products including phthalates. Methods: Phthalate metabolites, mono-ethyl phthalate (MEP), mono-n-butyl phthalate (MnBP), mono-isobutyl phthalate (MiBP), mono-2- ethylhexyl phthalate (MEHP), {(mono-(2-ethyl-5-hydroxyhexyl) phthalate (MEHHP}, and mono-(2-ethlyl-5-oxohexyl) phthalate (MEOHP} were examined. 80 urine samples collected from university students were analyzed using LC/MS/MS(API 4000, Applied Bioscience) with on-line enrichment and columnswitching techniques. This study was carried out at Y university located in Gyonggi Province from 2008 to 2011. Results: The detection limit of phthalate metabolites were 0.03 ng/mL for MEP, 0.11 ng/mL for MnBP, 0.08 ng/mL for MiBP, 0.93 ng/mL for MEHP, 0.19 ng/mL for MEOHP and 0.16ng/mL for MEHHP. MnBP showed the highest urinary levels (median: 31.6 ug/L, 24.8 ug/g creatinine (cr)). Concentrations were also high for MEHHP (median: 24.1 ug/L, 19.0 ug/g cr), followed by MEOHP (median: 22.8 ug/L, 17.9 ug/g cr). In individual cases, the maximum level reached up to 348 ug/L, and 291 ug/g cr, respectively. The urinary and creatinine adjusted levels of MEP were lower than those for DBP and DEHP metabolites, but were higher in 95th percentiles. As a result, the mean daily DEP intake value was 2.3 ${\mu}g/kg$ bw/day, 3.5 ${\mu}g/kg$ bw/day for DEHP and 4.9 ${\mu}g/kg$ bw/day for DBP. Conclusion: These students' phthalate exposure levels were below the international safe level set by the EU, but higher than the 2012 KFDA survey of the age group from 3 to 18.

Study on 222Rn reduction rate in boiling groundwater (가열에 의한 지하수 중 222Rn 제거율 고찰)

  • Kim, MoonSu;Kim, Hyun-Koo;Park, Sun-Wha;Kim, Hyoung-Seop;Ju, Byoung-Kyu;Kim, Dong-Su;Cho, Sung-Jin;Yang, Jae-Ha;Kwon, Oh-Sang;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.353-360
    • /
    • 2015
  • Boiling is an efficient removal method to reduce radon in groundwater when ventilating indoor air. 13 groundwater samples with various radon concentrations were used to evaluate the reduction rate of radon with heating temperature and time. The groundwater samples were obtained by Bladder pump and on-situ measurements such as dissolved oxygen (DO) and hydrogen concentration (pH) and so on were carried out by a flow cell system isolated from the ambient atmosphere environment. All samples for measuring radon in groundwater were analyzed by liquid scintillation counter (LSC). The experiment result showed that increasing groundwater temperature enhanced radon removal rate but the initial radon concentration with high level lowered the removal rate. This means that radon reduction in groundwater by heating needs more heating energy and longer heating time with radon concentrations. Radon removal rate in groundwater, therefore, mainly depends on the initial radon concentration, heating temperature, and heating time.

The Effect of The Index of Indoor Environment on The Productivity (실내환경지수가 생산성에 미치는 영향)

  • Kim, Myung-Ho;Lee, Ye-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.615-621
    • /
    • 2018
  • To enhance the energy saving and comfort of indoors, this study performed a stimulation of sound fluctuation, color temperature, and aroma. The experiment with EEG, HRV, and Vibra images was conducted in an environmental test room with a temperature of $25[^{\circ}C]$, relative humidity of 50[RH%], air current speed of 0.002[m/s], and illuminance of 1000[lux]. The stimulation experiment set up different sensory stimulation conditions, such as before exposure, single-sensory stimulation of fluctuation a=1.106 jazz music, single-sensory stimulation of RED color lighting, single-sensory stimulation of scent aroma, and multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma. After the multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting and scent aroma, the capacity for work and attention were increased, and the stress index and fatigue degree were decreased. In addition, multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma were effective in maintaining a stable heart and health. In addition, the Vibra image appeared to decrease tension/anxiety and stress. The multi-sensory stimulation of fluctuation a=1.106 jazz music, RED color lighting, and scent aroma help increase the Neuro-energy more than that by no exposure and single-sensory stimulation.

A Study on the Low Concentration Carbon Dioxide Adsorbent and Optimal Conditions (저농도 이산화탄소 포집용 흡착제 개발 및 최적조건에 관한 연구)

  • Lee, Ju-Yeol;Park, Duck-Shin;Cho, Young-Min;Kwon, Soon-Park;Hwang, Yoon-Ho;Song, Hyung-Jin;Lee, Sang-Bong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, $CO_2$ adsorbent was developed for removing low concentration of $CO_2$ in multiple-use facilities. The efficiency of the adsorbent which was improved selective $CO_2$ adsorption capabilities was evaluated. The pellet type adsorbent was modified from a commercial zeolite with mixing LiOH, binder, additives, and $H_2O$. Column tests showed over 90 % of $CO_2$ was adsorbed within 400min. Chamber tests including batch and continuous types were performed for evaluating the adsorbent module. By batch tests, it was evaluated that about 92% of $CO_2$ was removed within 30 min. By continuous tests, 70% of $CO_2$ was removed within 30 min. It was analyzed that over 2,500 ppm of $CO_2$ was continuously removed as shown chamber tests. The reproducibility tests repeatedly performed for 15 days shows that over 1,000 ppm of $CO_2$ was continuously removed. Adsorption capacity of the developed adsorbent was 5.0mmol $CO_2/g$ adsorbent which was analyzed by TGA. It was estimated that the modified adsorbent was applicable to low $CO_2$ concentration and low temperature of indoor environment.

Exposure Assessment of Solvents and Toluene Diisocyanates among Polyurethane Waterproofing Workers in the Construction industry (건설현장 우레탄 방수작업자의 휘발성 유기화합물 및 톨루엔 디이소시아네이트 노출평가)

  • Park, Hyunhee;Hwang, Eunsong;Ro, Jiwon;Jang, Kwangmyung;Park, Seunghyun;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.134-152
    • /
    • 2020
  • Objectives: The objective of this study was to evaluate volatile organic compounds (VOCs) and toluene diisocyanates (TDIs) exposure among polyurethane waterproofing workers in the construction industry. Methods: Task-based personal air samplings were carried out at seven construction sites using organic vapor monitor for VOCs (n=88) and glass fiber filters coated with 1-(2-pyridyl)piperazine(1-2PP) for TDIs (n=81). The concentration of VOCs and TDIs were shown for four different work types(mixing paint, primer roller painting, urethane resin spread painting, painter assistant) at five different worksites (rooftop, ground parking lot, piloti, bathroom, and swimming pool). The two TDI sampling methods (filter vs impinger) were evaluated in parallel to compare the concentrations. Results: The geometric mean(GM) concentration of VOCs Exposure Index (EI) was highest for primer roller painting (1.4), followed in order by, urethane resin spread painting (0.85), mixing paint (0.53), and painter assistant (0.35) by work types. The GM of VOCs EI was highest for bathroom (1.4) followed in order by, swimming pool (0.85), piloti (0.89), ground parking lot (0.82) and rooftop (0.57) by worksites. The GM of 2,4-/2,6-TDI concentration was 0.052 ppb and 0.432 ppb each. There was no statistical difference in TDIs concentrations among worksites. The concentration of 2,6-TDI was ten times higher than that of 2,4-TDI. The concentration of 2,6-TDI by impinger method was 5.7 times higher than that by filter method. Conclusions: In this study, we found 38.6% of the VOCs samples exceeded the occupational exposure limits and 19.8% of the 2,6-TDI samples exceeded 1 ppb among polyurethane waterproofing workers. The most important determinants that increase the concentration of VOCs and TDIs was indoor environment and primer painting work.

Prioritization of Species Selection Criteria for Urban Fine Dust Reduction Planting (도시 미세먼지 저감 식재를 위한 수종 선정 기준의 우선순위 도출)

  • Cho, Dong-Gil
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.4
    • /
    • pp.472-480
    • /
    • 2019
  • Selection of the plant material for planting to reduce fine dust should comprehensively consider the visual characteristics, such as the shape and texture of the plant leaves and form of bark, which affect the adsorption function of the plant. However, previous studies on reduction of fine dust through plants have focused on the absorption function rather than the adsorption function of plants and on foliage plants, which are indoor plants, rather than the outdoor plants. In particular, the criterion for selection of fine dust reduction species is not specific, so research on the selection criteria for plant materials for fine dust reduction in urban areas is needed. The purpose of this study is to identify the priorities of eight indicators that affect the fine dust reduction by using the fuzzy multi-criteria decision-making model (MCDM) and establish the tree selection criteria for the urban planting to reduce fine dust. For the purpose, we conducted a questionnaire survey of those who majored in fine dust-related academic fields and those with experience of researching fine dust. A result of the survey showed that the area of leaf and the tree species received the highest score as the factors that affect the fine dust reduction. They were followed by the surface roughness of leaves, tree height, growth rate, complexity of leaves, edge shape of leaves, and bark feature in that order. When selecting the species that have leaves with the coarse surface, it is better to select the trees with wooly, glossy, and waxy layers on the leaves. When considering the shape of the leaves, it is better to select the two-type or three-type leaves and palm-shaped leaves than the single-type leaves and to select the serrated leaves than the smooth edged leaves to increase the surface area for adsorbing fine dust in the air on the surface of the leaves. When considering the characteristics of the bark, it is better to select trees that have cork layers or show or are likely to show the bark loosening or cracks than to select those with lenticel or patterned barks. This study is significant in that it presents the priorities of the selection criteria of plant material based on the visual characteristics that affect the adsorption of fine dust for the planning of planting to reduce fine dust in the urban area. The results of this study can be used as basic data for the selection of trees for plantation planning in the urban area.

Effects of Dry Eye Symptoms on Work Productivity and General Activity in Newly Building (신축건물에서 안구건조증이 작업생산성과 일상활동에 미치는 영향)

  • Kim, Hyojin;Park, Chan-Jung;Lim, Byung-Seo;Kim, Ho-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.389-396
    • /
    • 2014
  • Purpose: The study examined dry eye symptoms of occupants in a newly constructed building and its effects on their work productivity and general activity. Methods: The study subjects were 33 office workers who spent more than eight hours per day on average in a new building constructed in the past three months. The indoor air quality of the new building was evaluated by measuring aldehydes, temperature and humidity. The level of dry eye symptoms was classified into normal, mild, moderate and severe by using the Ocular Surface Disease Index (OSDI). The experience of LASIK surgery, use of eye makeup, daily use time of a computer and smart-phone, and average daily working hours were also examined. The Work Limitation Productivity Questionnaire was used as the questionnaire about work productivity and general activity to measure the impairment level on a ten-point scale. Results: The concentration variation of formaldehyde in the office was $42.42{\pm}6.30{\mu}g/m^3$. The temperature and humidity were $26.2{\pm}0.70^{\circ}C$ and $40{\pm}1%$, respectively. The respondents with normal, mild, moderate and severe dry eye symptoms were 15.2%, 18.2%, 18.2% and 48.5%, respectively. The severity of dry eye symptoms and impairment of work productivity and general activity demonstrated high correlations of 0.599 and 0.655, respectively (p<0.001). Compared to the normal case, severe dry eye symptoms demonstrated significantly high impairment of work productivity and interruption of general activity (p<0.001). The case of serious dry symptoms showed the possibilities of having impairment level of work productivity and interruption of general activity above three points 3.26 times (p=0.032) and 2.25 times (p=0.045), respectively, higher than that of the normal case. Conclusions: It was confirmed that dry eye symptoms among office workers in a newly constructed building affects work productivity and general activity.