• Title/Summary/Keyword: Indoor Air Temperature

Search Result 669, Processing Time 0.025 seconds

An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units (기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석)

  • Yoo, Bok-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

An Experimental Study on Thermal Stratification of Pressurized Plenum Underfloor Air Distribution System during Cooling (가압식 바닥급기 시스템의 여름철 성층화 경향에 관한 실험적 연구)

  • Kim, Dong-Hee;Yu, Ki-Hyung;Cho, Dong-Woo;Seo, Jung-Seok;Han, Sung-Phil
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.340-345
    • /
    • 2007
  • The underfloor air distribution system has been attracting to architects and building owners as one of valuable system for the renovated and newly office building. In this paper, we discussed the thermal stratification profile of pressurized plenum underfloor air distribution(UFAD) according to indoor setting temperature, diffuser number, diffuser type. For this, the space of office building(H corp.) is selected for measuring the air volume of underfloor diffuser and vertical temperature profile. As a result, the thermal stratification profile is influenced by the number and type of the underfloor diffuser and thermal storage character of the underfloor. Whereas indoor setting temperature have a lower significant impact on thermal stratification.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Development of Methods for Evaluation of Indoor Thermal Environment of Apartment Housing (공동주택의 실내 열환경에 대한 평가방법개발)

  • 윤정숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.6
    • /
    • pp.101-110
    • /
    • 1997
  • The intent of this study is to propose a method for appraisal of the indoor thermal environment of apartment housing by measuring physical factors and residents' response to questionnaire survey. The experiments were performed on eight houses each in summer (August 18 through 31,1995) and winer (february 16 through 20,1996). It included measurements of indoor air temperature, globe temperature, relative humidity, and CO2 concentration. The questionnaire surveys were performed each in summer (July 16 through 20, 1996) and winer (February 13 through 16, 1996). And 248 cases in summer and 297 cases in winter were used in analysis. These questionnaire surveys asked residents' response about thermal sensation, humidity sensation, sense of air freshness regarding the indoor thermal environment. data acquired through the experiments and questionnaire surveys were then transferred to scales that allowed relative comparison, and measured to an appraisal standard chart. Appraisal tools included appraisal charts and radar charts. Indoor thermal environment was judged to be positive according to experiments, but residents appraised the thermal environment to be average. This difference between the two can be found in the strict standards by which residents judge the thermal environment of their apartments.

  • PDF

An Investigation of Indoor Air Quality of Public Transportation System in Seoul City (서울시의 대중교통수단내 실내공기질에 대한 연구)

  • 김윤신;홍승철;전준민
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.1
    • /
    • pp.28-38
    • /
    • 1994
  • The objective of this study were to measure concentrations of indoor pollutants in public transportation systems to provide importance of indoor air quality in transportation systems to policy makers. Indoor air quality of the pollutants (CO, CO$_2$, PM-10) and environmental sources (temperature, humidity) were measured at subway, seat-type bus, and city-type bus in the Seoul area from April to September 1992. The same pollutants and environmental sources were also measured at selected bus stops and subway stations during October 1991-September 1992. The mean concentrations of indoor pollutants in the public transportation systems were showed 115.5 $\mu$g/m$^3$ in PM-10, 6.8 ppm in CO, and 2167.9 ppm in CO$_2$, respectively. The mean values of PM-10 and CO showed below the U.S. 24 hour standard value of PM-10 and the Korea ambient CO standard, while the mean concentrations of CO$_2$ exceeded the Korea CO$_2$ standard. The highest levels of indoor concentration at public transportation systems were PM-10 of 134.6 $\mu$g/m$^3$ in the subway, CO of 8.9 ppm in the city-type bus, CO$_2$ of 2,511.1ppm in seat-type bus, respectively. The results showed that indoor air quality in bus and subway seemed likely to be affected by number of passengers and outdoor air infiltrated from exhausted gases of automobiles.

  • PDF

A Study on Characteristics of Indoor- Air-Quality in Interior Space Equipped with System Air-Conditioner (시스템 에어컨 설치 공간의 실내공기질 특성에 관한 연구)

  • Lee, Sang-Won;Kim, Jong-Min;Yeum, Seung-Won;Cho, Dae-Gun;Choi, Jae-Boong;Kim, Seok-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.304-313
    • /
    • 2008
  • This paper investigates the indoor-air-quality (IAQ) characteristics of the interior space equipped with system air-conditioner. The behaviors of individual variables such as temperature, humidity and concentration of carbon dioxide ($CO_2$) that influence on IAQ of the interior space were characterized under various cooling conditions by numerical and experimental studies. The numerical analysis predicting the temperature behavior of the interior space was conducted, and its results showed a good agreement with the experimental ones. The $CO_2$ concentration and humidity were measured and their time dependent behaviors were monitored and analyzed. From the results, it was found that there existed the differences of the time-dependent behaviors of IAQ variables according to the locations. In addition, it is demonstrated that the large discharge angle of $45^{\circ}$ made the temperature profile more irregular and the high discharge flow of 5.34 m/s produced similar temperature profiles at three different sensing locations. Finally, the humidity of interior space was less sensitive to the changes of the air cooling conditions than the case of temperature and the $CO_2$ concentration increase mainly depended on the number of individuals inside the space.

A Study on the Establishment of the Optimal Temperature Limits for Man's Thermal Comfort in an Asymmetric Radiant Space (불균등 복사공간의 쾌적온도범위 설정에 관한 연구)

  • Sohn, Jang-Yeul;Kong, Sung-Hoon;Yun, Yong-Jin
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.14 no.3
    • /
    • pp.187-199
    • /
    • 1985
  • The low-temperatured radiant heating System like a panel heating system is recognized as nice means to make comfortable indoor environment. Perhaps, 'Ondol' would be a typical example of the Panel heating system. Nevertheless. Occupants in a radiantly heated Space which has an asymmetric radiant field may feel thermally discomfort due to the asymmetric radiation. The aim of this Study is to suggest the fundamental technical data for establishing Standards of thermally comfortable environment when designing a radiant heating System. Thermal distribution of indoor environment and the skin temperature of the occupants were measured at experimental room in KIER (Korea Institute of Energy and Resources). Whole/Regional thermal and comfort Sensation votes of the occupants were taken simultaneously in order to investigate the relationships between thermal environmental factor and the occupants' responses. The effect of an asymmetric radiation on thermal environment and the occupants' responses was analyzed by using a v.r.t.(vector radiant temperature). By this means, the thermally neutral limits for the ambient air temperature and the floor surface temperature by the occupants' responses were Obtained. And the recommended temperature limits of the indoor surface were derived from the experimental work and the theory of radiant and will provide thermal neutrality for man without any discomfort on the part of the body.

  • PDF

The Field Measurement and Analysis of Indoor Thermal Environment in Large Enclosures (대공간의 실내온열환경 실측 및 분석)

  • Chae, Mun-Byoung;Yang, Jeong-Hoon;Choi, Dong-Ho;Seok, Ho-Tae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.1
    • /
    • pp.77-88
    • /
    • 2008
  • This research aims to divide the large enclosures according to summer and winter seasons, and to measure changes in the indoor thermal conditions. Also, with regard to air conditioning and exterior environments, it aims to identify the characteristics of indoor thermal environments such as indoor vertical and horizontal temperature distribution in large enclosures, temperature distribution in the audience's seating, indoor surface temperature distribution, wind speed distribution in the audience's seating, and indoor thermal comfort.

  • PDF

Characteristics of thermal comfort for artificial environment experiment in summer (하계 인공환경실험에서의 온열쾌적특성)

  • 박종일;김경훈;홍희기;민병일;김창주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.3
    • /
    • pp.368-377
    • /
    • 1998
  • The purpose of this study was to examine theory about indoor thermal comfort-environment as well as to determine thermal sensation and physiological responses for men in summer indoor environment, under various air temperature and relative humidity, with male university students. Subjective Evaluation, Heart Rate(Electrocardiogram), Electroencephalogram(EEG) were examined. We found that comfort of people was achieved at SE $T^{*}$ 24.7$^{\circ}C$, -0.82<PMV<0.93, subject's clothing(0.41c1o)and the difference of skin temperature was found at the calf area as air temperature changes. At low SE $T^{*}$, heart rate was decreased and at high SE $T^{*}$, heart rate was increased but there was no change EEG(keeping $\alpha$-wave).wave).

  • PDF

Influence on the Thermal Environment by Change of Indoor-air Volume of Plastic Greenhouse with Hot Air Heating Systems (온풍난방을 채용한 3연동 플라스틱 하우스의 실내공기용적 변화가 하우스 온열환경에 미치는 영향)

  • Jeon, Sam-Chae;Li, Chang-Su;Na, Su-Yeun;Huh, Jong-Chul;Choi, Dong-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Relatively being economical in installation and easy in operation, hot-air heating system has been generally used in greenhouse for heating system regardless of high cost in maintenance and uneven distribution of air temperature. Therefore to overcome the disadvantages in maintenance and in distribution of air temperature and to improve efficiency of heating system, this experimental study is performed. This experimental study aims to improve the character of uneven temperature distribution in vertical direction and to reduce energy consumption for heating in a greenhouse. The experiment had been performed to investigate change of thermal environment and effects on reducing energy consumption for heating in greenhouse by additional surface insulation and reduction of indoor-air volume that come by installing transparent vinyl membranes with different height in each house. The results show that there is a wide difference in oil-energy consumption between houses according to condition of surface insulation and change of indoor-air volume. Furthermore, the results show that the efficiency of dual surface is higher than that of change of indoor-air volume in terms of energy saving.