• Title/Summary/Keyword: Indoor Air Control

Search Result 455, Processing Time 0.031 seconds

Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner (실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율)

  • Park, Sungjae;Park, Geunyoung;Park, Dae Hoon;Koo, Hyunbon;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.16 no.4
    • /
    • pp.73-94
    • /
    • 2020
  • Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

The Air Pollution Prevention and Control Division's Program within U.S. EPA's Office of Research and Development

  • Princiotta, Frank T.
    • Clean Technology
    • /
    • v.2 no.2
    • /
    • pp.30-41
    • /
    • 1996
  • Air pollution problems are serious and present significant challenges to the engineering research community. EPA's engineering research programs have shifted from a primary focus on $SO_2$ and NOx pollution control to more complex and more difficult problems such as indoor air quality, air toxics, and global climate change. EPA research engineers are working closely with other research organizations in both the private sector and other federal research organizations to identify, evaluate, and develop cost-effective engineering solutions. The APPCE works closely with the EPA regulatory and regional offices to ensure that the best engineering information is utilized to formulate and implement the Agency's environmental protection program.

  • PDF

Implementation of Indoor Environment Monitoring and Automatic Control System based on Internet of Things (사물인터넷 기반 실내 환경 모니터링 및 자동제어 시스템 구현)

  • Lee, Sang Hoon;Kim, Jin-Yeop;Kim, Su-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2016
  • Along with the increase in the standard of living, the interest and awareness level of the public about environmental issues have also gradually increased. Recently, time spent on indoor activities have increased and the need for awareness and demand on methods in improving the quality of an indoor environment has been recognized. The purpose of this study is to sense the environment information through real-time monitoring of the room environment by using the IoT based technology and to maintain and improve the indoor environment to an appropriate level through the developed interlocking controller device. This provides an automatic control system in improving the indoor environment at home and other small areas like general offices in place of the traditional passive interior environmental improvement actions or large-scale facility control system. A status analysis with the relative reference values of the air quality and CO2, temperature and humidity and illumination and noise was applied through transmitting a control signal to automatic control module in accordance with the nine indoor environment standards set to improve the indoor environment.

Efficiency of Removal of Indoor Pollutants by Pistia stratiotes, Eichhornia crassipes and Hydrocotyle umbellata

  • Park, Hye-Min;Lee, Ae-Kyung
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • In this study, we compared efficiency of different aquatic plants in removing indoor pollutants and examined their potential to purify indoor air. Two liter of water in chamber was used as the control, while the other chambers containing water lettuce (Pistia stratiotes), water hyacinth (Eichhornia crassipes), and water coin (Hydrocotyle umbellata) were used as treatment groups. Temperatures inside all the chambers were maintained between 20 ℃ and 23 ℃. Humidity in the chambers with aquatic plants increased by 30% and 50% control respectively. The removal of formaldehyde per unit leaf area was examined in each aquatic plant. It turned out that water hyacinth removed the highest amount of formaldehyde, followed by water lettuce and water coin. Both water hyacinth and water lettuce increased the amount of removal of formaldehyde until the end of the experiment. In the case of airborne dust (PM 10) and fine dust (PM 2.5), water coin, which had the highest number of leaves, removed more PM 10 and PM 2.5 than the other aquatic plants, with statistically significant difference. In addition, both water coin and water hyacinth smoothly opened and closed stomata before and after the experiment. Consequently, as the aquatic plants were effective in controlling humidity and removing pollutants, they can be used as air purifying plants.

Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV (PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석)

  • Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.4
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Consideration of Ozone Removal and Control in Built Environment by Building Materials (건축자재에 의한 실내 오존제거 및 제어에 대한 고찰)

  • Chung, Ok-Young;Jeong, Su-Gwang;Kim, Jun-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.467-475
    • /
    • 2012
  • Recently, residents have been spending almost 90% of their time indoors, which presents a higher risk from inhalation of pollutants than when spending time outdoors. Therefore, controlling indoor air quality became important. It is reported that the lung diseases and mortality for occupants are increased when there is high density of ozone which is one of the pollutants among the indoor air. In addition, the reactions between ozone and building materials produce VOCs and formaldehyde. The studies to eliminate the ozone by building materials have been actively investigated. However, ozone removal and secondary pollutants from ozone reactions with building materials have not been reported in Korea. For this reason, the aim of this study is to introduce ozone removal by HVAC filters, various building materials, and eco-friendly building materials including the quantity of secondary pollutant emissions.