• Title/Summary/Keyword: Individual room control

Search Result 52, Processing Time 0.024 seconds

A study for finding human non-habitual behavior in daily life

  • Shimada, Yasuyuki;Matsumoto, Tsutomu;Kawaji, Shigeyasu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.491-496
    • /
    • 2003
  • This paper proposes modeling of human behavior and a method of finding irregular human behavior. At first, human behavior model is proposed by paying attention to habitual human behavior at home. Generally, it is difficult to obtain the information of individual life pattern because of high cost for setting sensors such as cameras to observe human action. Therefore we capture turning on/off consumer electronic equipments as actual human behavior action, where some or many consumer electric equipments were used such as television, room light, video and so on in our daily life. Noting that are some relations between turning on/off those consumer electric equipments and our action, we proposes how to construct a human behavior knowledge by analyzing human behavior based on observation of human habitual life. Also an algorithm to identify on find irregular behavior different from habitual life behavior are described. Finally, the significance of the proposed method is shown by some experimental results.

  • PDF

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

A study on the state of infection control in dental clinic (치과진료실에서의 감염관리 실태 조사)

  • Kim, Kyung-Mi;Jung, Jae-Yeon;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.3
    • /
    • pp.213-230
    • /
    • 2007
  • The purpose of this study was to examine the state of infection control provided to members of Korean Dental Hygienists Association. The subjects in this study were dental hygienists who attended a symposium on July 1. 2006. after a survey was conducted, the answer sheets from 489 participants were analyzed, and the findings of the study were as follows: 1. Possession of disinfection room was being(72.7%), and person of infection control was zero(52.9%). Number of sterilizer was one(62.2%). 2. As a repetition choice, type of sterilizer was autoclave(97.9%), UV sterilizer(67.4%) and EO gas sterilizer(21.4%). As a repetition choice, infection materials was ethanol(84.1%). 3. Water tube of unit and chair was using of sterilized water(42.9%). Sterilizing of compressed air was no(69.0%). 4. Re-using of disposal was not using(62.5%), re-using disposal was suction tip(28.2%)(repetition choice) 5. In sterilization of instruments, hand-piece was every using time(28.4%), and reamer-file, bur, mirror, pincette, explorer, hand scaler and ultrasonic scaler were high in every using time. 6. Individual protection was high of using, cleaning of hands before treatment was every treatment(87.0%). Type of soap was liquid type in dental clinic(48.2%), infection soap in dental hospital(41.2%) and solid soap in public health center(50.6%). Answered that they need regular oral health education, and 82.9% respondents answered that they need oral health technicians in school. And 87.8% respondents needed individual oral health education for the benefit of better oral health.

  • PDF

Design of Central and Local Control of Air-conditioning System (중앙 및 국부 제어 가능한 에어컨 제어시스템 설계)

  • Park, Cha-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.68-73
    • /
    • 2011
  • In this study, a group of home bus system(HBS) is used to manage difference types of household appliances or many household appliance of the same type. The existing central controller is analyzed, and an independent control system is built to devise new methods to design the PC HBS. The newly designed system is installed in an air-conditioned building; the system can be monitored and controlled from a control room or from an office. By using the system, we can efficiently manage future energy needs and control large-scale integrated electronics and home automation system to an individual manage to build large is expected to contribute.

Gender Differences in Problematic Online Behavior of Adolescent Users over Time (남녀 청소년 소비자의 온라인 문제행동 차이에 대한 종단 분석)

  • Kim, Jung Eun
    • Human Ecology Research
    • /
    • v.53 no.6
    • /
    • pp.641-654
    • /
    • 2015
  • This study identifies and tracks changes gender differences in adolescent users' problematic online behavior. This study used Korea Youth Panel Survey (KYPS), which has tracked respondents over 7 years, with self-control theory and social learning theory applied as a theoretical framework. The model included individual-level variables such as self-control and respondent's experience of problematic behavior (offline), as well as socialization variables such as the number close friends who engaged in problematic offline behavior, parent-child relationships, and parental monitoring. Dependent variables included problematic online behavior, unauthorized ID use (ID theft) and cyberbullying (cursing/insulting someone in a chat room or on a bulletin board). Control variables consisted of academic performance, time spent on a computer, monthly household income, and father's educational attainment. Random and fixed effects models were performed by gender. Results supported self-control theory even for the within-level analysis (fixed effects models) regardless of gender, while social learning theory was partially supported. Only peer effects were found significant (except for unauthorized ID use) among girls. Year dummy variables showed significant negative associations; however, academic performance and time spent using computers were significant in some models. Father's educational attainment and monthly household income were found insignificant, even in the random effects models. We also discuss implications and suggestions for future research and policy makers.

A study on the moving picture transmission method between the accident sites and control center (사고현장과 사령실간 화상전송기술에 관한 연구)

  • 장석각;조봉관
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.484-489
    • /
    • 2002
  • Whenever the accidents occur in the railway areas, their prompt recovery is very important. The individual way has been used to resolve these accidents by direct visiting the site and reporting to others who cares for these cases. As a result, we are planning to operate the MTS (Moving picture Transmission System) for a timely information's transmission to the related peoples in the central control center by transforming the picture information on the accident-site to the digital information. The proposed system is not a transmission system using exclusive lines, but utilizing the existing railway computer network. We construct a network server device so that a dispatcher can easily connect with the server through the railway intranet. In some railway environments such as disturbed field situations and geographical condition(in tunnels and bridges, etc) building up the wired network is difficult. Solving this problem, we reviewed the wireless network. Finally we proposed the mixed wireless network that is able to cover the wired network. We then installed and tested the wired network and wireless network respectively in wayside of a railway field. Through the testing, we identified many detailed matters for some network construction approaches to the control room and many field device-connecting schemes. This research will contribute to minimize the number of staff dispatched to a disturbed field, decrease the accident recovery time and improve the quality of service to the passenger.

  • PDF

Study on Daylight Inflow Environment Consequent on the Length of Light Shelf and Slat Angle Control for Fostering Visual Environment in Patient Rooms of Hospital - By Dynamic Daylight Simulation Using Weather Data - (종합병원 병실 내 시환경 조성을 위한 광선반 길이 및 Slat각 제어에 따른 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Cho, Ju Young;Lee, Ki Ho;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.113-121
    • /
    • 2012
  • A hospital is the most important infra-facility of the places which take care of people's body in social environment. There exist several environmental factors in the ways to heal the human body in hospital ward, but this study tried to look into the improvable pleasant sickroom environment with focus on light environment among the factors. In other words, this study aims at the research on proper daylight inflow into sickroom space as basic data for understanding the link between healing environment and natural lighting. In the simulation analysis through this research, this study completed the initial simulation using Autodesk Revit 2011 with focus on two types of individual multi-bed room units of the two general hospitals located in Gwangju City. This study made a simulation analysis of The two multi-bed rooms looking to the west using the weather data on Gwangju district, which is the strong point of ECOTECT2011. Conclusively, looking into the analysis of the simulation model in time of attaching the length of in & outside light shelf, the angle controlling of light shelf, the daylight factor and DA were found to show the tendency to decrease in the numerical value due to the decrease in sunlight inflow as the simulation model moved more toward the room from the window in comparison with the existing analysis of multi-bed rooms. Particularly, this study was able to read that the daylight factor and DA were more decreasing to improve at the light shelf than the existing bedrooms; conclusively, this study judges that the natural lighting simulation analysis could be helpful in improving the healing environment as basic data.

An Efficient Method of Workflow Management using a Dispatching Rule (우선순위규칙을 이용한 워크플로우의 효율적 운영 방안)

  • 이승현;유우식;배혜림;김영호;박용태
    • Korean Management Science Review
    • /
    • v.20 no.2
    • /
    • pp.17-31
    • /
    • 2003
  • A workflow management system is a software system to support accurate execution, control and management of business processes. It has been known that the system automatically executes complex processes and effectively manages them to improve the productivities. However though existing systems assure the automatic execution of an individual process, there is a room for enhancement from the view of efficient execution of all the processes. In this paper, we propose a method of executing business processes efficiently by introducing the PERT/CPM techniques in the workflow management systems. We first consider the differences between workflow process models and PERT/CPM models, and then develop a method of calculating the critical path and slack time in workflow processes. This leads us to develop a dispatching rule that can guide task performers to prioritize their tasks to increase the efficiency of ail the processes. We have carried out a set of simulation experiments and analyzed the results to demonstrate the effectiveness of the proposed method.

Development of HVAC System to Lower the Conveyance Energy and Building Height (반송동력과 건물층고 저감형 공조시스템 개발)

  • 김정엽;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.