• 제목/요약/키워드: Indirect radiation

검색결과 110건 처리시간 0.021초

Indirect assessment of internal irradiation from tritium decay on Lemna Minor duckweed

  • Ifayefunmi, O.S.;Mirseabasov, O.A.;Synzynys, B.I.
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1991-1999
    • /
    • 2021
  • The response changes of the specific growth rate of Lemna minor duckweed was modeled using the logarithms of frond numbers on tritium activity concentration and gamma radiation dose from cobalt 60. The concept of average specific growth rate depends on the general exponential growth pattern, where toxicity is estimated based on the effect on the growth rate. One of the main questions of the effect of the radiation dose on duckweed is how to correlate the effect of beta radiation with the effect of any other radiation for modeling radiation on Lemna minor. Experimental data were extrapolated by utilizing the OECD guidelines. A linear relationship of absorbed dose and activity concentration was obtained for the average dependency growth rate of Lemna minor as D = (0.1257)·A0.585. The dose rate of gamma irradiation from 60Co increases with tritium activity dependence, on the specific growth rate of the Lemna minor duckweed. An increase in the tritium activity causes a decrease in the specific growth rate of the Lemna minor duckweed. It indicates that as the quantity of the beta radiation dose increase in Lemna minor duckweed, a higher quantity of gamma radiation will be required to cause the same effect in the specific growth rate of Lemna minor duckweed. The relation between the inhibition of the Lemna minor seedling growth and gamma and beta radiation dosage agrees roughly with that between the decrease of survival rate or fertility and dosage.

WRF-Chem 모델을 활용하여 장마 기간 황해에서 발달하는 한랭운과 에어로졸 미세물리 과정 분석: 2017년 7월 15일 사례 (Cold Cloud Genesis and Microphysical Dynamics in the Yellow Sea using WRF-Chem Model: A Case Study of the July 15, 2017 Event)

  • 이범중;조재희;김학성
    • 한국지구과학회지
    • /
    • 제44권6호
    • /
    • pp.578-593
    • /
    • 2023
  • 2017년 7월 15일 서울과 수도권에 집중호우를 발생시킨 깊은 대류운과 강수 발달에 대한 종관 기상 메커니즘을 규명하고 중국 동부지역으로부터의 PM2.5 에어로졸의 간접효과를 WRF-Chem 실험을 통해 분석하였다. WRF-Chem 모델에 에어로졸과 복사의 피드백, 구름 화학 과정, 습식 세정을 모두 포함한 ARI (Aerosol Radiation Interaction) 실험과 에어로졸과 복사의 피드백을 제외하고 구름 화학 과정, 습식 세정만을 포함한 ACR (Aerosol Cloud Radiation interaction) 실험 결과의 차이로부터 PM2.5 에어로졸 간접효과를 산출하였다. 2017년 7월 15일 새벽에 황해와 한반도에서는 동아시아 대륙에서 저기압-북서 태평양의 고기압 분포로 인해 중국 남동 지역과 동중국해로부터 덥고 습한 기류가 수렴하고 있었다. 이러한 황해의 종관 기상에 의해 발달하는 대류운은 높이 12 km 이상이며 고체 수상체를 형성하고 있었는데, 이는 주로 대륙 위에서 발달하는 한랭운(많은 빙정을 형성하며 운정고도가 8 km 이상)의 특성을 나타내고 있었다. 특히, WRF-Chem 모델 실험을 통해 중국 동부지역으로부터 확산하는 PM2.5 에어로졸이 구름물 형성에 5.7%, 고체 수상체 형성에 10.4%, 그리고 액체 수상체 형성에 10.8%로 대류운이 한랭운으로 발달하는 데 기여하고 있었다. 본 연구는 황해 위에서 깊은 대류운이 발달하는 과정에 대한 기상적 메커니즘과 더불어 중국 동부지역으로부터 에어로졸에 의한 간접효과의 영향을 제시하였다.

직.간접디지털 파노라마 방사선촬영시 흡수선량과 유효선량 (Absorbed and effective dose in direct and indirect digital panoramic radiography)

  • 이근선;김진수;김재덕
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.9-14
    • /
    • 2010
  • Purpose : We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. Materials and Methods : The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), $^nLi_2B_4O_7$ TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. Results : The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p<0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. Conclusion : The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

Comparison Study on Changes of Antigenicities of Egg Ovalbumin Irradiated by Electron Beam or X-Ray

  • Kim, Mi-Jung;Lee, Ju-Woon;Sung, Nak-Yoon;Kim, Su-Min;Hwang, Young-Jung;Kim, Jae-Hun;Song, Beom-Seok
    • 한국축산식품학회지
    • /
    • 제34권5호
    • /
    • pp.570-575
    • /
    • 2014
  • This study was conducted to compare the effects of two forms of radiation (electron and X-ray; generated by an electron beam accelerator) on the conformation and antigenic properties of hen's egg albumin, ovalbumin (OVA), which was used as a model protein. OVA solutions (2.0 mg/mL) were individually irradiated by electron beam or X-ray at the absorbed doses of 0 (control), 2, 4, 6, 8, and 10 kGy. No differences between the two forms of radiation on the structural properties of OVA were shown by spectrometric and electrophoretic analyses. The turbidity of OVA solution increased and the main OVA bands on polyacrylamide gels disappeared after irradiation, regardless of the radiation source. In competitive indirect enzyme-linked immunosorbent assay, OVA samples irradiated by electron beam or X-ray showed different immunological responses in reactions with monoclonal and polyclonal antibodies (immunoglobulin G) produced against non-irradiated OVA. The results indicate that electron beam irradiation and X-ray irradiation produced different patterns of structural changes to the OVA molecule.

방사선치료 안내동영상 제작 (Producing Radiotherapy Guidance Movie for patients)

  • 왕철환;강승희;문봉기;박동욱;원영진;박광현;김주현;방승미
    • 한국의료질향상학회지
    • /
    • 제19권1호
    • /
    • pp.56-61
    • /
    • 2013
  • Objectives: This video has been produced to provide better awareness for our patients about radiotherapy treatment for anxiety and stress. This video will give inexperienced patients a better understanding of the processes and expectations of the radiotherapy. We have produced a radiotherapy guidance video regarding work flow and a method of radiotherapy to relieve anxiety and stress. It also improves patients satisfaction and understanding of radiotherapy to provide a high-quality health care for radiotherapy patients with indirect experience. Methods: We have evaluated the effectiveness of the video compared to our existing verbal method. See below for the evaluation criteria; 1) Patients satisfaction rate of guidance 2) a comparison of understanding of radiotherapy 3) a comparison of a time of education for patients 4) a researching of an incidence rate of radiotherapy. Results: When compared to the verbal explanation the patients had a increased level of understanding of the radiotherapy treatment. The time to educate patient was decreased and the level of incidents during the treatment was decreased due to the patient having a better understanding of the whole process. Conclusion : In conclusion, the audiovisual education increased the understanding of radiotherapy for patients compared to verbal education. The video also helped patients to cooperate in treatment room so we can provide premium radiotherapy treatment. By reducing the treatment time and education processa we improved the patients overall experience.

  • PDF

$BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교 (Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor)

  • 최장용;박지군;공현기;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Parecoxib: an Enhancer of Radiation Therapy for Colorectal Cancer

  • Xiong, Wei;Li, Wen-Hui;Jiang, Yong-Xin;Liu, Shan;Ai, Yi-Qin;Liu, Rong;Chang, Li;Zhang, Ming;Wang, Xiao-Li;Bai, Han;Wang, Hong;Zheng, Rui;Tan, Jing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권2호
    • /
    • pp.627-633
    • /
    • 2015
  • Background: To study the effect of parecoxib, a novel cyclooxygenase-2 selective inhibitor, on the radiation response of colorectal cancer (CRC) cells and its underlying mechanisms. Materials and Methods: Both in vitro colony formation and apoptosis assays as well as in vivo mouse xenograft experiments were used to explore the radiosensitizing effects of parecoxib in human HCT116 and HT29 CRC cells. Results: Parecoxib sensitized CRC cells to radiation in vitro with a sensitivity enhancement ratio of 1.32 for HCT116 cells and 1.15 for HT29 cells at a surviving fraction of 0.37. This effect was partially attributable to enhanced apoptosis induction by parecoxib combined with radiation, as illustrated using an in vitro apoptosis assays. Parecoxib augmented the tumor response of HCT116 xenografts to radiation, achieving growth delay more than 20 days and an enhancement factor of 1.53. In accordance with the in vitro results, parecoxib combined with radiation resulted in less proliferation and more apoptosis in tumors than radiation alone. Radiation monotherapy decreased microvessel density (MVD) and microvessel intensity (MVI), but increased the hypoxia level in xenografts. Parecoxib did not affect MVD, but it increased MVI and attenuated hypoxia. Conclusions: Parecoxib can effectively enhance radiation sensitivity in CRC cells through direct effects on tumor cells and indirect effects on tumor vasculature.

전리방사선이 세포질 소기관의 미세구조변화와 기전에 미치는 영향 (The Effect of Ionizing Radiation on the Ultrastructural Changes and Mechanism on the Cytoplasmic Organelles)

  • 이무석;이종규;남지호;하태영;임영현;길상형
    • 생명과학회지
    • /
    • 제27권6호
    • /
    • pp.708-725
    • /
    • 2017
  • 전리방사선은 물질과 상호작용하여 원자내의 중성자나 양성자, 궤도전자를 충분히 제거시킬 수 있는 에너지이다. 이와 같은 전리방사선은 DNA이나 세포질 소기관과 세포질의 방사선 분해 생성물을 통해 직접적, 간접적으로 상호작용하여 분자구조를 변화시키는 산화적 대사를 일으킨다. 이러한 전리 현상은 분자수준에서 조직을 손상시키고, 세포 기능을 파괴할 수 있다. 따라서, 전리방사선에 의해 유도된 이온채널과 수송 변형이 보고되고 있다. 이러한 현상이 항상성을 유지하기 위한 생화학적 과정을 무너뜨리면, 유도된 생물학적 변화가 지속되고 후대로 영향을 미친다. 또한, 전리방사선의 영향으로 형성된 활성산소는 세포연접을 통해 인접세포로 퍼져 나갈 수 있다. 방사선량, 선량률, 선질에 따라 이러한 메커니즘이 충분히 방어할 수도 있고 그렇지 않을 수도 있다. 본 총설에서는 방사선생물학의 개념을 뒷받침하는 전리방사선의 세포수준에서 생물학적 효과에 대한 보고서를 간략히 알아보았다. 전리방사선의 생물학적 효과를 잘 이해하면 방사선을 잘 이용할 수 있고, 방사선피폭으로부터 더 나은 방호를 할 수 있을 것이다.

디지털방사선사진과 구내방사선사진의 인접면 인공우식진단능에 관한 비교연구 (COMPARATIVE STUDY OF DIGITAL AND CONVENTIONAL RADIOGRAPHY FOR THE DIAGNOSTIC ABILITY OF ARTIFICIAL PROXIMAL SURFACE CARIES)

  • 조영곤;박시승
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.113-121
    • /
    • 2002
  • Conventional intraoral radiography continues to be the most widely used image modality for the diagnosis of dental caries. But, conventional intraoral radiography has several shortcomings, including the difficulty of exposing and processing intraoral film of consistently acceptable quality. In addition, radiographic retaking that was the result of processing errors, may result in increased discomfort and radiation dose to the patient. Recently, various digital radiographies substitute for conventional intraoral radiography to overcome these disadvantages. The advantages of digital radiography are numerous. One of advantages Is the elimination of processing errors. In addition, the radiation dose for digital system is approximately 20% to 25% of that required for conventional intraoral radiography Another potential advantage of digital imaging is the ability to perform image quality enhancements such as contrast and density modulation, which may increase diagnostic accuracy. The purpose of this study was to compare the diagnostic ability of artificial proximal defects to conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). Artificial defects were made in proximal surfaces of 60 extracted human molars using #1/2, #1, #2 round bur. Five dentists assessed proximal defects on conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital image(Digora$^{\circledR}$). ROC(Receiver Operating Characteristic) analysis and Two-way ANOVA test were used for the evaluation of detectability, and following results were acquired. 1. The mean ROC area of conventional intraoral radiography, direct digital image(CDX2000HQ$^{\circledR}$) and indirect digital Image(Digora$^{\circledR}$) were 0.6766, 0.7538, 0.6791(Grade I), 0.7176, 0.7594, 0.7361(Grade II), and 0.7449, 0.7608, 0.7414(Grade III), respectively. 2. Diagnostic ability of direct digital image was higher than other image modalities. But, there was no statistically significant difference among other imaging modalities for Grade I, II, III lesion(p>0.05). In conclusion, when direct and indirect digital system are comparable with conventional intraoral radiography. these systems may be considered an alternative of conventional intraoral radiography for the diagnosis of proximal surface caries.

로터리 킬른 스케일 업을 위한 열전달 특성 고찰 (The Heat Transfer Characteristics Analysis of Rotary Kiln for Scale Up)

  • 엄민제;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.97-98
    • /
    • 2012
  • The rotary kiln is one of the most widely used industrial reactors for contacting gases and solids. Kilns are mainly used for drying, calcining and reducing solid materials. In an indirected fired rotary kiln, heat is supplied to the outside of the kiln wall. Heat transfer in indirected fired rotary kilns encompasses all the modes of transport mechanisms, that is, conduction, convection and radiation. This paper deal with the heat transfer characteristics of indirect fired rotary kiln for scale up.

  • PDF