• Title/Summary/Keyword: Indicated efficiency

Search Result 1,319, Processing Time 0.031 seconds

An Analysis of Efficiency in Major University Hospitals in Domestically Capital Area Through DEA Analysis (DEA분석을 통한 국내 수도권 주요 대학병원의 효율성 분석)

  • Park, Byeong-Tae;Lee, Dong-Hyeon
    • Korea Journal of Hospital Management
    • /
    • v.16 no.4
    • /
    • pp.35-66
    • /
    • 2011
  • This study analyzed efficiency by utilizing DEA analytical technique centering on materials for 2009 of 20 major university hospitals in capital area. Input variables were utilized professor & full-time doctor, resident, nurse & number of bed hospitals. Output variables were analyzed by dividing number of annual outpatients & number of annual inpatients, and annually total outpatient profit & inpatient profit into a model of the standard for number of patients and the standard for medical profit. DEA analysis was elicited efficiency score by applying CCR, BCC, BFG, scale profit, and SE model. Through t-test after eliciting efficiency score, the implications were suggested by comparing efficiency between DMU in Seoul and DMU in capital area, by comparing between high-class general hospitals and general hospitals, and by comparing between high-class general hospitals in Seoul and 5 big hospitals. As a result of analysis, the major university hospitals in capital area showed high efficiency as a whole close to "1," but indicated low efficiency relatively in CCR field. Thus, the expansion in scale within capital area was indicated to reach the limit. Second, in a model of analyzing the standard for number of patients, the medical institutions, which are being operated efficiently, were indicated to be 10 DMUs. In the standard for medical profit, 12 DMUs were analyzed to be operated efficiently. Third, the efficiency in general hospital was higher than high-class general hospital. Thus, the efficiency of operation was indicated to be more important than scale. Also, large high-class hospitals(big 5) where are located in downtown Seoul showed the higher efficiency than other general high-class general hospitals, but were indicating very low efficiency in some DMUs. Fourth, as a result of generalizing and evaluating the number of patients and the medical profit, the efficient DMU was indicated to be more when analyzing on the basis of medical profit than the standard for number of patients. Thus, major university hospitals in capital area were indicated to make more effort for section in medical profit. Based on the analytical results of efficiency, a strategy for reinforcing efficiency in inefficient DMU was indicated to be needed a strategy of creating customers for promoting number of patients and a strategy for making operation efficient for increasing profitability.

  • PDF

Application of $A^2$/O Process for Removal of Nitrogen and Phosphorus in Sewage (하수중의 질소.인 제거를 위한 $A^2$/O공정의 적용)

  • 안철우;박진식;문추연
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.9-14
    • /
    • 2000
  • In this study, the removal efficiencies of organics, nitrogens and phosphorus from municipal wastewater using $A^2$/O process were investigated. BO $D_{5}$ removal efficiencies were indicated 95% and 94% with HRT of 12 hr and 10 hr, respectively. CO $D_{Cr}$ average removal efficiency and concentration of effluent were indicated 87% and 34mg/$\ell$. SS average removal efficiency and concentration of effluent were indicated 93% and 4~17mg/$\ell$. T-N removal efficiency and concentration of effluent were shown as 60~80% and below 15mg/$\ell$. In aerobic basin, removal efficiency of N $H_4$-N was shown over 97% with N $H_4$-N volume load 0.16kg N $H_4$-N/㎥.d and in anoxic basin, denitrification efficiency was indicated over 80% with return sludge rate 0.5Q and internal recirculation rate 2.5Q. Removal efficiency and effluent concentration of phosphorus were shown over 80% and below 2 mg/$\ell$ with return sludge rate 0.5Q.Q.

  • PDF

A Study on the Performance Analysis of Francis Hydraulic Turbine

  • Ha, Jin-Ho;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.1052-1059
    • /
    • 2009
  • The effects of varying the inlet flow angle on the output power of a Francis hydraulic turbine were studied numerically and the result was compared to the experimental results conducted at Korea Institute of Energy Research to determine the brake power of the turbine for each set of operating conditions. The loss of mechanical power of the model turbine was determined by comparing the numerical and experimental results, and thus the turbine efficiency or energy conversion efficiency of the model turbine could be estimated. From the result, it was found that the maximum brake efficiency of the turbine is approximately 46% at an induced angle of 35 degrees. The maximum indicated mechanical efficiency of the turbine is approximately 93% at an induced angle of 25~30 degrees.

Design and Development of Fluidized Bed Cleaning System for on Heat Treatment Parts (I) - Design and Development the Experimental Fluidized Bed Cleaner and Experiments on its Cleaning Efficiency - (유동층을 이용한 열처리부품의 세정 시스템 설계 및 개발 (I) -유동층 이용 세정 실험장치 설계, 개발 및 실험 -)

  • Kim C.S.;Kim K.D.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.376-384
    • /
    • 2006
  • This study was conducted to perform for comparative analysis of the cleaning efficiency on 3 kinds of cleaning liquid state, 3 steps of cleaning temperature $(45^{\circ}C,\;60^{\circ}C,\;70^{\circ}C,\;)$ and 6 steps of cleaning time (2.5, 5, 7.5, 10, 12.5, 15 minute). 3 kinds of cleaning liquid state are the non fluidized bed, liquid fluidized bed and liquid/solid fluidized bed. UV spectrophotometer was used in estimation of cleaning efficiency, which it is experimental equipment using the absorptiometric analysis method. Cleaning efficiency by cleaning time was increase from 2.5 minutes to 15 minutes, liquid/siolid fluidized bed was indicated the highest cleaning efficiency among the 3 kinds of cleaning liquid state and $70^{\circ}C$ of cleaning temperature at liquid/solid fluidized bed was indicated the highest cleaning efficiency as 98% among the 3 steps of cleaning temperature.

A Study on Management Efficiency of Korean Ship Component Part Manufacturers

  • Kim, Myung-Jae
    • Journal of Navigation and Port Research
    • /
    • v.34 no.7
    • /
    • pp.577-585
    • /
    • 2010
  • This paper analyzes the efficiency of Korean Ship Component Part Manufacturer firms using DEA model. We evaluated the CCR, BCC efficiency and RTS of 30 Korea Ship Component Part Manufacturer firms. We also suggested the Korean Ship Component Part Manufacturer firms that can be benchmarked based on analyzed information. The result showed five enterprises whose values of CCR efficiency are 1, and eleven enterprises whose values of BCC efficiency are 1. RTS indicated IRS of 1 firms, DRS of 24 firms and CRS of 5 firms.

Efficiency and Productivity on ICT Industry (ICT 제조업과 서비스업의 효율성과 생산성)

  • Jeong, Boon-Do
    • International Commerce and Information Review
    • /
    • v.16 no.4
    • /
    • pp.55-75
    • /
    • 2014
  • Non-parametric method such as technology efficiency, DEA/Window model and Malmquist Productivity Index (MPI) are used to measure efficiency and productivity of ICT (Information and Communication Technology) manufacturing industry and service industry over the period 2007-2011. The results of this paper indicate following: (1) Technology efficiency of the ICT manufacturing industry were found as the range of 0.34 and 0.39 over the sample period. Technology efficiency of the ICT service industry were found as the range of 0.16 and 0.20 over the sample period. (2) The geometric average of the Malmquist TFP indexes on ICT manufacturing industry indicated the productivity improvement an average of 8.3 percent. The geometric average of the Malmquist TFP indexes on ICT service industry indicated the productivity improvement an average of 1.6 percent. (3) TIER analysis result on ICT manufacturing industry showed that optimal bench marking made by storage devices${\rightarrow}$wireless communication equipment${\rightarrow}$broadcasting equipment${\rightarrow}$radio, recording and playback devices${\rightarrow}$computers, printers, video and audio-visual equipment path. TIER analysis result on ICT service industry indicated that optimal bench marking made by computers and packaged software${\rightarrow}$wired communication${\rightarrow}$communication, information, detection equipment${\rightarrow}$consulting and construction for computer systems integration${\rightarrow}$industrial machinery and equipment rental${\rightarrow}$telecommunications reseller${\rightarrow}$system software development and delivery${\rightarrow}$hosting path.

  • PDF

Differences in liver microRNA profiling in pigs with low and high feed efficiency

  • Miao, Yuanxin;Fu, Chuanke;Liao, Mingxing;Fang, Fang
    • Journal of Animal Science and Technology
    • /
    • v.64 no.2
    • /
    • pp.312-329
    • /
    • 2022
  • Feed cost is the main factor affecting the economic benefits of pig industry. Improving the feed efficiency (FE) can reduce the feed cost and improve the economic benefits of pig breeding enterprises. Liver is a complex metabolic organ which affects the distribution of nutrients and regulates the efficiency of energy conversion from nutrients to muscle or fat, thereby affecting feed efficiency. MicroRNAs (miRNAs) are small non-coding RNAs that can regulate feed efficiency through the modulation of gene expression at the post-transcriptional level. In this study, we analyzed miRNA profiling of liver tissues in High-FE and Low-FE pigs for the purpose of identifying key miRNAs related to feed efficiency. A total 212~221 annotated porcine miRNAs and 136~281 novel miRNAs were identified in the pig liver. Among them, 188 annotated miRNAs were co-expressed in High-FE and Low-FE pigs. The 14 miRNAs were significantly differentially expressed (DE) in the livers of high-FE pigs and low-FE pigs, of which 5 were downregulated and 9 were upregulated. Kyoto Encyclopedia of Genes and Genomes analysis of liver DE miRNAs in high-FE pigs and low-FE pigs indicated that the target genes of DE miRNAs were significantly enriched in insulin signaling pathway, Gonadotropin-releasing hormone signaling pathway, and mammalian target of rapamycin signaling pathway. To verify the reliability of sequencing results, 5 DE miRNAs were randomly selected for quantitative reverse transcription-polymerase chain reaction (qRT-PCR). The qRT-PCR results of miRNAs were confirmed to be consistent with sequencing data. DE miRNA data indicated that liver-specific miRNAs synergistically acted with mRNAs to improve feed efficiency. The liver miRNAs expression analysis revealed the metabolic pathways by which the liver miRNAs regulate pig feed efficiency.

Tendency of Kindergarten Teachers' Work Performance and the Reality and Efficiency of their Working Hours (유치원 교사의 업무수행 경향성과 업무시간 운영의 실제 및 효율성에 대한 인식)

  • Ahn, Hye Jung;Lee, Seung Yeon
    • Korean Journal of Child Care and Education Policy
    • /
    • v.12 no.3
    • /
    • pp.3-27
    • /
    • 2018
  • The purposes of this study were to examine a tendency of kindergarten teachers' daily work performance and to explore their perceptions on the reality and efficiency of working hours. 273 public and private kindergarten teachers completed questionnaires. The findings of the study are as follows. First, kindergarten teachers carried out an average of 1.41 duties per a 30-minute segment, and there were some differences in their duties between public and private teachers. Second, as a key reason of their lack of preparation time for class, public teachers indicated much administrative work, whereas private teachers indicated many events and common work. In addition, for the work duties that require supporting staff, public teachers pointed out clerical work, whereas private teachers named event-related duties. Third, in terms of efficiency of their working hours, both public and private teachers highlighted excessive workload as a key obstacle; public teachers also indicated the shortage of supporting staff, while private teachers indicated many event-related duties and lack of directors' leadership. These findings imply that it is important to maintain an optimum level of workload for kindergarten teachers, to secure preparation time for class, to increase work efficiency, and to provide support specific to kindergarten types.

Effect of Distance between Finger Tip and Root Width on Compressive Strength Performance of Finger-Jointed Timber (핑거공차가 핑거접합재의 압축강도 성능에 미치는 영향)

  • Ryu, Hyun-Soo;Ahn, Sang-Yeol;Park, Han-Min;Byeon, Hee-Seop;Kim, Jong-Man
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.66-73
    • /
    • 2004
  • Three species of Italian poplar (Populus euramericana), red pine (Pinus densiflora) and oriental oak (Quercus variabilis) were selected for this study. They were cut so that the distances between each of tips and roots for a pair of fingers were 0, 0.15, 0.30 and 0.45 mm. Poly vinyl acetate (PVAc) and resorcinol-phenol resin (RPR) were used for finger-jointing. Compressive test parallel to the grain was conducted for the finger-jointed specimens. The results were as follows: The efficiency of compressive Young's modulus of finger-jointed timber to solid wood indicated low values, whereas the efficiency of compressive strength indicated high values of more than 90% in all species, especially, it was found that those of red pine indicated markedly high values of more than 97%. The efficiency of compressive displacement of Italian poplar finger-jointed timber was 2 times higher than solid wood, and it was 1.2 and 1.3 times higher than solid woods in red pine and oriental oak, respectively. Also, it was found that 0, the distance between each tip and root for the fingers, indicated the highest efficiency of compressive strength performance in Italian poplar finger-jointed timber, and for red pine and oriental oak finger-jointed timbers, the distances of 0.15 and 0.30 were found to indicate the highest efficiency.

An Experimental Study on RCCI(Reactivity Controlled Compression Ignition) Combustion of Dual-fuel due to Injector Characteristics (인젝터 특성에 따른 2중 연료의 RCCI 연소에 관한 실험적 연구)

  • Sung, Ki-An
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.110-115
    • /
    • 2012
  • This study describes the characteristics of combustion and exhaust emission in the special engine applying a fuel reactivity controlled compression ignition (RCCI) concept with two different energizing type (solenoid and piezoelectric) injectors for diesel injection. A diesel-gasoline mixed dual-fuel reactivity controlled compression ignition concept is demonstrated as a promising method to achieve high thermal efficiency and low emission in internal combustion engines for transportation vehicles. For investigating the combustion characteristics of RCCI, engine experiments were performed in a light-duty diesel engine over a range of injection timing and mixing rate of gasoline in mass. It was investigated that by increasing the nozzle hole diameter, increasing the combustion pressure and the net indicated mean effective pressure. $NO_x$ and soot can be reduced by advancing start of injection in 84 mixing rate of gasoline in mass. The resulting operation showed that light duty engine could achieve 48 percent net indicated efficiency and 191[g/kW-hr] net indicated specific fuel consumption with lower levels of nitrogen oxides and soot.