• Title/Summary/Keyword: Index ion

Search Result 197, Processing Time 0.033 seconds

Comparison of Sampling and Analytical Methods for Determining Airborne Hexavalent Chromium -Limit of Detection, Accuracy and Precision of Analytical Procedures (공기중 6가 크롬 측정 방법 비교 -검출한계, 정확도 및 정밀도-)

  • 신용철;이병규;이지태
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.1
    • /
    • pp.39-49
    • /
    • 2002
  • In this study, limits of detection (LOD), accuracy and precision of four sampling/ analytical methods were evaluated and compared for the determination of airborne hexavalent chromium, Cr (VI). The methods include : (1) a combination of the National Institute for Occupational Safety and Health (NIOSH) Method 7600/U. S. Environmental Protection Agency (EPA) Method 218.6 (NIOSH/EPA Method) proposed by Shin and Paik, 2) two impinger methods using 2% NaOH/3% Na$_2$CO$_3$. (3) same as (2) but with 0.02 N NaHCO$_3$absorbing solution, and (4) the Occupational Safety and Health (OSHA) Method ID-215. An ion chromatograph/visible absorbance detector was used for the analysis of Cr (VI) in sample solution. Limit of detection (LOD) , analytical accuracy, and precision were also tested using Cr (VI) spike samples. Recoveries (as index of accuracy) and coefficient of variation (CV) (as a index of precision) were determined. Two-way ANOVA and Turkey's test were performed to test the significance in differences among recoveries and CVs of the methods. In all the methods, the peaks of Cr (VI) were separated sharply on chromatograms and exhibited a strong linearity with Cr (VI) concentrations in solution. The correlation coefficients of calibration curves typically ranged from 0.9997 to 0.9999, and the analytical LODs from 0.025 to 0.1$\mu\textrm{g}$/sample. All the method had good sensitivities and linearities between Cr (VI) levels and peak areas. The accuracies (% mean recoveries) of the methods ranged from 80.1 to 104.2%, while the precisions (pooled coefficient of variation) ranged from 3.16 to 4.43%. The impinger methods showed higher recoveries ( > 95%) than those of the PVC filter methods (the OSHA Method and the NIOSH/EPA Method). It was assumed that Cr (VI) on PVC filter was exposed to air and reduced to trivalent chromium, Cr (III), whereas it was stabilized in alkali solution contained in impinger. Thus, a special treatment of Cr (VI) samples collected on PVC filters may be required.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

Effects of Oral Taurine Supplementation on Plasma Total and Phospholipid Fatty Acid Patterns in Healthy Female Adults (타우린 복용이 정상 성인여성의 혈장 총지방산 및 인지질 지방산패턴에 미치는 영향)

  • 박태선
    • Journal of Nutrition and Health
    • /
    • v.31 no.8
    • /
    • pp.1315-1323
    • /
    • 1998
  • Effect of oral taurine supplementation on plasma total and phospholidpid -fatty acid profiles and their metabolism were evaluated in healthy female adults. Among twenty five female volunteers(23.6$\pm$0.3 years old ) participated in the taruine supplementation program(6g taurine /day), twenty four subjects succesfully completed the 2 week program , and only nine subjects continued to take taurine for another 2 weeks. Levels of plasma fatty acids and taruine were measured by gas-liquid chromatobraphy and an automated amino acid analyzer based on ion exchange chromatography, respectively. Plasma taurine concentration s of the subjects were 108. 7$\pm$3.4 , 184.2$\pm$8.2 and 235.9$\pm$77.0$\mu$emol/L at 0 , 2 and 4 weeks of taurine supplementation. Fatty acid compositions and elongation and desaturation indices of polyunsaturated fatty acids (PUFA) in plasma total lipids were not influenced by oral taurine supplementation. However, fatty acid compositions and their metabolism in plasma phospholipids were significantly affected by taurine supplementation in female adults. Compared to the values for 0 week, the percentage of saturated fatty acids (SFA) in plasma phospholipid was significantly lowered at 2 weeks, but elevated at 4 weeks of taurine supplementation. In contrast , the percentage of phospholipid PUFA significantly increased at 2 weeks and decreased at 4 weeks of taurine supplementation from to the values for 0 weeks. Foru weeks of oral taurine supplementation signifinatly elevated the eongation index(20 : 4$\omega$6 ⇒22 : 4 $\omega$6, p<0.01), and decreased the desaturation index (20 : 3 $\omega$6 ⇒20 : 4 $\omega$6 , p<0.01) of $\omega$6 fatty acids in plasma phospholipids. Plasma taurine concentration was positively correlated with the percentage of 14 : 0 fatty acids and the enlongation index o f$\omega$3 fatty acids(20 : 5 $\omega$3 ⇒22 : 5 $\omega$3), and thenegatively correlated with the percentage of 20 : 0 in plasma phospholipids. These results indicate that oral taurine supplementation for 4 weeks signidicantly elelvated the percentage of SFA, and lowered the percentage of PUFA in plasma phospholipids with no influence on plasm total fatty aicd composition in healthy female adults.

  • PDF

Optical properties of $SiO_2$ and $TiO_2$ thin films deposited by electron beam process with and without ion-beam source (전자빔 증착시 이온빔 보조증착 장비의 사용에 따른 $SiO_2 & TiO_2$ 박막의 광학적 특성)

  • Song, M.K.;Yang, W.S.;Kwon, S.W.;Lee, H.M.;Kim, W.K.;Lee, H.Y.;Yoon, D.H.;Song, Y.S.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.17 no.4
    • /
    • pp.145-150
    • /
    • 2007
  • The $SiO_2$ and $TiO_2$ thin films for the multilayer interference filter application were manufactured by electron beam process. In case of electron beam process with ion source, the anode current was controlled by gas volume ratio of $O_2$ and Ar. Substrate temperature of electron beam deposition without ion source was increased from 100 to $250^{\circ}C$ with $50^{\circ}C$ increment. The surface roughness values of $SiO_2$ thin films was most low value at $200^{\circ}C$ substrate temperature and 0.2 A anode current respectively. And the surface roughness values of $TiO_2$ thin films was most low value at room temperature and 0.2 A anode current repectively. The refractive index of $SiO_2$ and $TiO_2$ thin films to be deposited with ion source was usually lower than that of thin films without ion source.

Mineral Components of Water Supply Plants and Spring Waters in Northern Gyeonggi Area (경기북부지역 정수장 및 약수터의 미네랄 성분 분포 연구)

  • Song, Hee-Il;Lim, Han-Su;Park, Gyoung-Su;Park, Hyun-Goo;Lee, Hyun-Jin;Jo, Mi-Hyun;Kim, Young-Yeon;Oh, Jo-Gyo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.238-246
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the distribution of mineral components, health and taste index for water supply plants, spring water located in northern Gyeonggi area and bottled waters in market to analyze Ca, K, Mg Na, Si, $F^-$ and $SO_4{^{2-}}$. Method: The samples were source and tap water in 15 water supply plants over 9 river basin, 172 spring water and 20 bottled water. The Ca, K, Mg Na and Si were analyzed by ICP-OES. The $F^-$ and $SO_4{^{2-}}$ were determined by Ion Chromatograph. Then, taste and health index were calculated using Hashimoto equation. Results: The average concentration of major minerals showed in same order of Ca > Na > Mg > K for all kinds of drinking water from water supply plants, spring waters and bottled waters. Total concentration of major minerals (Ca, K, Mg, Na) was calculated that showed 26.79 mg/L of tap water, 21.81 mg/L of spring water, 32.94 mg/L of bottled water on average. So, the spring waters indicated the lowest minerals sum. The tap water from water supply plants was categorized to Group I, II for 33.3, 44.4% according to K-index and O-index. Otherwise, spring water was classified as Group I, II for 44.0, 46.3%. Conclusion: According to the results of K and O-index, water from water supply plant showed higher K-index which means good for the health. Otherwise, spring water indicated higher O-index that people can feel more delicious than tap water. Futhermore, the mineral distribution of source water from water supply plants and spring water had indicated high correlation with geological effect.

Characteristics of silver ion-exchanged glass waveguides at 633nm and $1.5{\mu}m$ (은 이온 교환법으로 만든 유리 도자로의 633nm와 $1.5{\mu}m$에서의 특성 연구)

  • 유건호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.198-202
    • /
    • 1992
  • Silver ion-exchanged glass waveguide with its large surface index difference and shallow depth is suitable to be used for the hybrid integration of semiconductor device and glass waveguide using the semiconductor film grafting technique. We report characteristics of the planar and channel glass waveguides exchanged in the diluted silver nitrate melt in the visible and infrared spectral region. Especially, we determined the fabrication parameters for single-mode channel waveguide at 1.5.$\mu$m, an important wavelength in the optical communication. Directional couplers with several different configurations were fabricated, and their 3 dB coupling length was determined as a function of wavelenGh and polarization.

  • PDF

Heat sensitivity on physiological and biochemical traits in chickpea (Cicer arietinum)

  • Jain, Amit Kumar
    • Advances in environmental research
    • /
    • v.3 no.4
    • /
    • pp.307-319
    • /
    • 2014
  • Four chickpea cultivars viz. kabuli (Pusa 1088 and Pusa 1053) and desi (Pusa 1103 and Pusa 547) differing in sensitivity to high temperature conditions were analyzed in earthern pot (30 cm) at different stages of growth and development in the year of 2010 and 2011. Pusa-1053 (kabuli type) showed maximum photosynthetic rate and least by Pusa-547 (desi type), whereas maximum cell membrane thermostability were recorded in Pusa-1103 and minimum in Pusa-1088. Among the treatments, the plants grown under elevated temperature conditions had produced 13.01% more significant data in comparison to plants grown under continuous natural conditions. Stomatal conductance were reduced 44.25% under elevated temperature conditions than natural conditions, whereas 35.56%, when plants grown under initially natural conditions upto 30DAS, then 30-60DAS elevated temperature and finally shifted to natural conditions till harvest. In case of Pusa-1103, stomatal conductance was maximum as compared to rest of 2.7% from Pusa-1053, 8.9% from Pusa-1088, and 10.3% in Pusa-547 throughout the study. Plants grown under continuous elevated temperature conditions had produced 15.30% and 15.32% more significant membrane thermostability index in comparison to continuous natural conditions at vegetative stage and 19.40% and 18.44% at flowering stage, while the better response was recorded at pod formation stage. Pusa-1053 had given 2.8% more membrane thermostability index than Pusa-1088 and Pusa-1103 had given 1.6% more membrane thermostability index than Pusa-547 in the present study. The membrane disruption caused by high temperature may alter water ion and inorganic solutes movement, photosynthesis and respiration. Thus, thermostability of the cell membrane depends on the degree of the electrolyte leakage.

Additive Noise Reduction Algorithm for Mass Spectrum Analyzer (질량 스펙트럼 분석기를 위한 부가잡음제거 알고리즘)

  • Choi, Hun;Lee, Imgeun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • An additive noise reduction algorithm for a mass spectrum analyzer is proposed. From the measured ion signal, we first used an estimated threshold from the mode of the measured signal to eliminate background noises with the white Gaussian characteristics. Also, a signal block corresponding to each mass index is constructed to perform a second order curve fitting and a linear approximation to signal block. In this process, the effective signal block composed of only the ion signal can be reconstructed by removing the impulsive noises and the sample signals which are insufficient to be viewed as normal ion signals. By performing curve fitting on the effective signal block, the noise-free mass spectrum can be obtained. To evaluate the performance of the proposed method, a simulation was performed using the signals acquired from the development equipment. Simulation results show the validity of the threshold setting from the mode and the superiority of the proposed curve fitting and linear approximation based noise canceling algorithm.

Synthesis and Crystal Structure of Zinc Iodide in the Sodalite Cavities of Zeolite A (LTA)

  • Kim, Seok-Han;Park, Man;Son, Young-Ja;Lee, Hyung-Joo;Jeong, Gyo-Cheol;Bae, Myung-Nam;Lim, Woo-Taik
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.567-573
    • /
    • 2007
  • The crystal structure of ZnI2 molecule synthesized in zeolite A (LTA) has been studied by single-crystal X-ray diffraction techniques. A single crystal of |Zn6|[Si12Al12O48]-LTA, synthesized by the dynamic ion-exchange of |Na12|[Si12Al12O48]-LTA with aqueous 0.05 M Zn(NO3)2 and washed with deionized water, was placed in a stream of flowing 0.05 M KI in CH3OH at 294 K for four days. The resulting crystal structure of the product (|K6Zn3(KI)3(ZnI2)0.5|[Si12Al12O48]-LTA, a = 12.1690(10) A) was determined at 294 K by single-crystal X-ray diffraction in the space group Pm3m. It was refined with all measured reflections to the final error index R1 = 0.078 for 431 reflections which Fo > 4σ (Fo). At four crystallographically distinct positions, 3.5 Zn2+ and nine K+ ions per unit cell are found: three Zn2+ and five K+ ions lie on the 3-fold axes opposite 6-rings in the large cavity, two K+ ions are off the plane of the 8-rings, two K+ ions are recessed deeply off the plane of the 8-rings, and the remaining a half Zn2+ ion lie on the 3-fold axes opposite 6-rings in the sodalite cavity. A half Zn2+ ion and an I- ion per unit cell are found in the sodalite units, indicating the formation of a ZnI2 molecule in 50% of the sodalite cavities. Each ZnI2 (Zn-I = 3.35(5) A) is held in place by the coordination of its one Zn2+ ion to the zeolite framework oxygens and by the coordination of its two I- ions to K+ ions through 6-rings (I-K = 3.33(8) A). Three additional I- ions per unit cell are found opposite a 4-ring in the large cavity and form a K3I2+ and two K2ZnI3+ ionic clusters, respectively.

GIS technology for geotechnical estimation of ground foundation (지반의 지질공학적 특성분석을 위한 GIS 활용 연구)

  • 김윤종;김원영;유일현
    • Spatial Information Research
    • /
    • v.2 no.1
    • /
    • pp.39-46
    • /
    • 1994
  • GIS technique was applied to identify the geotechnical characte¬ristic of subsurface in a study area, and has produced a Geotechnical Esti¬mat ion Index(GEI) map. Groundwater level, soi I depth & weathered zone, and engineering properties of soils & rocks, were incorporated in the map through GIS. EGIS(Environmental Geologic Information System), developed by ARC/INFO GIS system, was used for this work. Environmental geologic database by EGIS was verified to be effective in analysis of engineering geological properties of the subsurface. Quantitative analysis of environmental and geotechnical information enable to develop a scoring system of GEI model, which was developed through evaluation of each goelogical factor with respect to the other factors.

  • PDF