• Title/Summary/Keyword: Independent drive

Search Result 160, Processing Time 0.023 seconds

Characteristic of Induction Motor Drives Fed by Three Leg and Five Leg Inverters

  • Talib, Md. Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Hasim, Ahmad Shukri Abu
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.806-813
    • /
    • 2013
  • This paper aims to compare the performance of three phase induction motor drives using Five Leg Inverter (FLI) and Three Leg Inverter (TLI) configurations. An Indirect Field Oriented Control (IFOC) method using a TLI is well established and incorporated for high performance speed drives in various industries. The FLI dual motor drive system on the other hand shows good workability in the independent control of two induction motor drives simultaneously. In this experiment, the IFOC method is utilized for both drive systems, and Space Vector Pulse Width Modulation (SVPWM) is used to generate pulses for both inverters. For the FLI, the Double Zero Sequence (DZS) Injection technique is used to generate the modulation signal. The complete experiment setup is done by using a DSpace 1103 controller board. The individual motor performances are analyzed using similar schemes, equipment setups and controller parameter values. The results show similar speed performance response capability between the single motor operation using a TLI system and the two motor operation using a FLI system based on the variable speed range either in forward or reverse operation. They also show similar load rejection abilities. However, the single motor with a TLI has a better power quality aspect such as ripple current and total harmonics distortion (THD).

A dual-path high linear amplifier for carrier aggregation

  • Kang, Dong-Woo;Choi, Jang-Hong
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.773-780
    • /
    • 2020
  • A 40 nm complementary metal oxide semiconductor carrier-aggregated drive amplifier with high linearity is presented for sub-GHz Internet of Things applications. The proposed drive amplifier consists of two high linear amplifiers, which are composed of five differential cascode cells. Carrier aggregation can be achieved by switching on both the driver amplifiers simultaneously and combining the two independent signals in the current mode. The common gate bias of the cascode cells is selected to maximize the output 1 dB compression point (P1dB) to support high-linear wideband applications, and is used for the local supply voltage of digital circuitry for gain control. The proposed circuit achieved an output P1dB of 10.7 dBm with over 22.8 dBm of output 3rd-order intercept point up to 0.9 GHz and demonstrated a 55 dBc adjacent channel leakage ratio (ACLR) for the 802.11af with -5 dBm channel power. To the best of our knowledge, this is the first demonstration of the wideband carrier-aggregated drive amplifier that achieves the highest ACLR performance.

The Optimal Design of Wear Pads for the Final Reduction Drive in Tactical Vehicles (전술차량용 종감속기 마모패드 최적설계에 관한 연구)

  • Shin, Hunyong;Lee, Yong-Jun;Ryu, Jungmin;Kang, Taewoo;Oh, Dae-san;Sim, Jungwook;Shin, Minsu;Son, Kwon-il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.54-59
    • /
    • 2019
  • The final reduction drive in tactical vehicles has a wear-pad that helps to maintain adequate end floating when the hub assay operates. The input axis and sun gear move repeatedly with the axis when tactical vehicle is operating. The hub assay is designed so that the wear pads won't seize during operation. Seizure of the wear pads during operation results in oil leakage. In our study, the fault mechanism was analyzed to prevent the seizure of the wear pads and an optimal design for the shape and material of the wear-pad was explored. We then observed the changes in temperature, shape, and material of several important parts.

Dual - Drive & - Emission Panel

  • Miyashita, Takuya;Naka, Shigeki;Okada, Hiroyuki;Onnagawa, Hiroyoshi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.707-710
    • /
    • 2004
  • We have proposed on dual-drive & -emission (DDE) panel based on organic light-emitting diodes (OLEDs). The device is composed on independent operation of two OLED structures with two transparent electrodes for data signals and an intermediate reflective electrode for common scan signal. Typical device structure is ITO / organic electroluminescent layer (1) /intermediate reflective electrode / organic electroluminescent layer (2) /transparent electrode. Symmetric bright emission could be obtained by applying AlNd as the intermediate reflective electrode and $MoO_3$ as a hole injection layer for upper device structure. The proposed panel is useful for emissive face-to-face panel exhibited for different images.

  • PDF

A Study on the Parallel Drive of Cold Cathode Fluorescent Lamp (CCFL) (냉음극 형광램프의 병렬구동에 관한 연구)

  • Kim, Cherl-Jin;Park, Hyun-Cherl;Park, Jung-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.149-151
    • /
    • 2008
  • This paper presents an architecture for driving multiple parallel cold cathode fluorescent lamps (CCFLs) for back lighting applications. The key to the architecture is a proposed capacitive coupling approach for lamp ignition. This system is consist of a flyback converter, a single inverter to drive multiple lamps and conductive floating reflector. The topology is capable of driving a number of parallel lamps with independent accurate lamp, current regulation and improving cost effectiveness with significant reduction in size and weight, compared to typical high frequency ac ballast. Experimental demonstration results for ten of parallel CCFLs with simultaneous ignition.

  • PDF

Dead Time Compensation Scheme Independent of Parameter Variations in an Inverter-fed PMSM Drive (파라미터 변화에 무관한 인버터 구동 PMSM의 데드타임 보상 기법)

  • Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.124-134
    • /
    • 2011
  • A new dead time compensation scheme that can exactly estimate the dead time and inverter nonlinearity under parameter variations is proposed for a PWM inverter-fed PMSM drive. The proposed scheme uses the fact that the sixth harmonic component in total disturbance estimated under the presence of various uncertainties is mainly caused by the dead time and inverter nonlinearity. The total disturbance due to the parameter variations as well as the dead time and inverter nonlinearity is estimated by the adaptive scheme. The sixth harmonic component is extracted from this total disturbance through harmonic analysis. The obtained sixth harmonic is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity in the stationary reference frame. The effectiveness of the proposed scheme is verified. Without requiring an additional hardware, the proposed scheme can effectively compensate the dead time and inverter nonlinearity even under the parameter variations.

A Real-Time Method for the Diagnosis of Multiple Switch Faults in NPC Inverters Based on Output Currents Analysis

  • Abadi, Mohsen Bandar;Mendes, Andre M.S.;Cruz, Sergio M.A.
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1415-1425
    • /
    • 2016
  • This paper presents a new approach for fault diagnosis in three-level neutral point clamped inverters. The proposed method is based on the average values of the positive and negative parts of normalized output currents. This method is capable of detecting and locating multiple open-circuit faults in the controlled power switches of converters in half of a fundamental period of those currents. The implementation of this diagnostic approach only requires two output currents of the inverter. Therefore, no additional sensors are needed other than the ones already used by the control system of a drive based on this type of converter. Moreover, through the normalization of currents, the diagnosis is independent of the load level of the converter. The performance and effectiveness of the proposed diagnostic technique are validated by experimental results obtained under steady-state and transient conditions.

DC/AC converters for the power generating system using fuel cell (연료전지 발전 시스템의 직류/교류 변환기)

  • Kim, Y.H.;Kwon, G.H.;Kim, J.S.;Jung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1035-1037
    • /
    • 1992
  • Generally, fuel cell has characteristics of low voltage, large current and voltage variation under load change. Therefore, DC output voltage of fuel cell is too low to convert into AC with high efficiency and good performance. For this reason, fuel cell generating system is composed of DC-DC converter and inverter in cascade. This paper used 2-phase boost DC-DC converter to obtain low distortion waveform and reduce input-output current ripple, and discussed inverter which can be operated in independent drive mode and utility line interface drive mode. Then, the change of modes can be achived smoothly.

  • PDF

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.

Feed and spindle motor currents as monitoring parameters in cutting process (절삭공정 모니터링을 위한 이송모터의 주축모터 전류)

  • 오영탁;김기대;주종남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.555-559
    • /
    • 2001
  • Feed and spindle motor currents are used toi monitor the cutting process practically. The sensitivity of spindle drive system is lower than that of feed drive system, but the cutting torque is represented well by the spindle motor current. During multi-axis cutting, it is difficult to calculate the resultant cutting force using feed motor currents, because each feed force is reflected by each axis feed motor current with different time delay. It is also difficult to compensate the frictional torque using the feed motor current, because the magnitude of the frictional torque is dependent of the feedrate, table position, and cutting direction. On the other hand, cutting torque can be estimated well using spindle motor current which is independent of the cutting direction.

  • PDF