• 제목/요약/키워드: Incremental loading test

검색결과 54건 처리시간 0.021초

공업용 플라스틱으로 보강된 비좌굴가새의 실험적 구조성능평가 (Experimental Structural Performance Evaluation of Precast-Buckling Restrained Brace Reinforced With Engineering Plastics)

  • 김유성;김기철;강주원;이준호
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.43-52
    • /
    • 2020
  • In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.

재하속도에 따른 압밀특성에 관한 실험적 고찰 (An Experimental Study on the Consolidation Characteristics with Loading Rate)

  • 채점식;소충섭;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1070-1077
    • /
    • 2005
  • The purpose of this study is to establish a proper criterion for the constant rate of loading consolidation(CRLC) test which is a kind of the continuous loading consolidation(CLC) and widely used as alternative methods to the incremental loading consolidation(ILC)test. With those results, the preconsolidation pressure estimated by the CRLC test turned out to be comparatively larger than that of the ILC test, and it is increased in proportion to the applied loading rates. However, the compression index in the CRLC test is less influenced on by the loading rates. The coefficient of consolidation and permeability in the CRLC test are dependent on excess pore pressure ratio mainly. In other words, if the pore pressure ratios are too low, the coefficient of consolidation and permeability become smaller than those of the ILC test. On the other hand, if the excess pore pressure ratios are too high, the coefficient of consolidation and permeability become so larger than those of the ILC test. Therefore, loading rates should be carefully determined to generate proper excess pore pressure ratio inside the soil specimen. From this study, good results are obtained from the CRLC test if the excess pore pressure ratios were in the range of 2.5 to 6.0 %, performed with loading rates between 0.0015 and 0.005 $kgf/cm^2/min$.

  • PDF

Development of finite element model using incremental endochronic theory for temperature sensitive material

  • Kerh, Tienfuan;Lin, Y.C.
    • Structural Engineering and Mechanics
    • /
    • 제16권2호
    • /
    • pp.115-126
    • /
    • 2003
  • A novel finite element model based on the incremental endochronic theory with the effect of temperature was developed in this study to explore the deformed behaviors of a flexible pavement material. Three mesh systems and two loading steps were used in the calculation process for a specimen of three-dimensional circular cylinder. Computational results in the case of an uni-axial compression test for temperatures at $20^{\circ}C$ and at $40^{\circ}C$ were compared with available experimental measurements to verify the ability of developing numerical scheme. The isotropic response and the deviatoric response due to the thermal effect were presented from deformations in different profiles and displacement plots for the entire specimen. The characteristics of changing asphalt concrete material under a specified loading condition might be seen clearly from the numerical results, and might provide an useful information in the field of road engineering.

포화된 사질토에서 등방재하시험에 의한 비배수 공극수압의 거동분석 (Analysis of the Behavior of Undrained Pore Water Pressure in Saturated Sand by Isotropic Loading Test)

  • 임성훈
    • 한국농공학회논문집
    • /
    • 제47권4호
    • /
    • pp.43-52
    • /
    • 2005
  • It is known in some literatures that the B value is not equal to unity in saturated soil when effective stress is given, in which the B Value is the ratio of measured excess pore water pressure and isometric loading pressure. In this study the B value was measured on various effective stresses and on various incremental loading stresses in various grain size of specimens with saturated sand. The test results showed that the B value was affected largely by grain size of sand in specimen and the amount of effective stress. There was the semi-logarithmic relationship between B value and effective stress, and also there was the linear relationship between the gradient of the former semi-logarithmic relationship and grain size of specimen.

단조 반복하중 하의 탄소섬유시트 보강 RC보의 거동에 관한 연구 (Behavior of RC Beams Strengthened with Carbon Fiber SheetsUnder Repeated Loading)

  • 박정용;김성도;조백순;정진환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권4호
    • /
    • pp.183-193
    • /
    • 2006
  • 본 연구는 탄소섬유시트로 보강된 철근콘크리트 보에 정적하중과 반복하중이 작용할 때의 거동을 다루고 있다. 탄소섬유시트로 보강된 RC보의 정적실험 결과를 기준으로 반복하중 실험을 수행하였다. 반복하중 실험의 변수는 탄소섬유시트 겹수, 단부 U밴드 유무, 반복하중 재하속도 등이 있다. 실험결과를 통해 단조증가하중과 반복하중 하에서의 에너지 소산량과 휨 강성의 변화, 연성특성, 강도특성, 휨 거동 등을 고찰하며, 또한 탄소섬유시트의 파단변형률을 평가하였다. 본 연구에서는 반복하중 실험 결과를 바탕으로 탄소섬유시트로 보강된 RC보의 정적 및 동적 휨 보강 해석 및 설계에 필요한 기초자료를 제시하고자 한다.

제하-재재하 시 CRS 압밀 시험의 최적 변형률 속도 (Optimal Strain Rate of Unloading-Reloading Cycle in Constant Rate of Strain Consoildation Test)

  • 박가현;윤찬영;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1156-1167
    • /
    • 2010
  • The constant rate of strain (CRS) consolidation test has been widely used to evaluate consolidation characteristics of soils instead of the standard Incremental Loading Test. In practical problems, after the ground improvement, the condition of the soil is over-consolidated. Therefore, it is important to determine the recompression indices and the coefficient of consolidation(or the coefficient of swelling) of unloading-reloading cycle to predict the settlement behavior. However, since standard testing procedures or studies related with strain rate are insufficient especially in unloading-reloading cycle, it is difficult to predict the settlement field behavior accurately from the CRS consolidation test results in spite of its lots of strengths. The several CRS consolidation tests were performed changing the unloading strain rate from 0.2%/hr to 20%/hr with vertical drainage condition using the reconstituted kaolinite sample. For the reconstituted kaolinite sample in CRS consolidation test, the recompression indices are insensitive to the strain rate. It is revealed that the coefficient of consolidation of reloading is affected by the developed pore pressure during unloading. Additionally, the test should be conducted in the positive pore pressure ratio range (3~15%) to obtain the reasonable coefficient of consolidation in the whole range(loading, unloading and reloading).

  • PDF

피로 하중을 받는 철근콘크리트 구조물의 안전성에 관한 연구 (A Study on the Safety of Reinforced Concrete Structures under Fatigue Load)

  • 채원규
    • 한국안전학회지
    • /
    • 제9권2호
    • /
    • pp.18-25
    • /
    • 1994
  • In this thesis, the fatigue tests were performed on a series of reinforced concrete to Investigate the variation of strength and the safety of reinforced concrete structures under fatigue load. The specimens were of the same rectangular cross-section, of effective height 24cm and width 30cm and their span was 330cm. The three point loading system is used in the fatigue tests. In these tests, the fracture mode of reinforced concrete structures under fatigue load, relationship between the repeated loading cycles and the mid-span displacement of the specimens were observed. According to the test results, the following fatigue behavior of reinforced concrete specimens were observed. By increasing of the number of repeated loading cycles, the mid-span displacement became greater, however the Incremental amounts of the displacement were reduced. It could be also known that the inelastic strain energy of the doubly reinforced rectangular beams was larger than that of the singly reinforced rectangular beams as increasing the number of repeated loading cycles. Compliance of reinforced concrete structures tended to be reduced as increasing the repeated loading cycles, and the compliance of the doubly reinforced rectangular beams was generally smaller than that of the singly reinforced rectangular beams. Based on the above investigation, it could be concluded that the doubly reinforced rectangular beams under fatigue load were more efficient to resist the brittle fracture than the singly reinforced rectangular beams.

  • PDF

소성지수에 따른 점성토의 압밀특성에 관한 연구 (A study on the Consolidation Characteristic of Cohesive Soil by Plastic Index)

  • 김찬기;조원범;이승련;최우정
    • 한국지반공학회논문집
    • /
    • 제24권8호
    • /
    • pp.99-109
    • /
    • 2008
  • 본 연구는 군산 새만금지역의 점성토를 소성지수 15%, 30%, 45%, 60%가 되도록 벤초나이트를 첨가한 인공의 시료를 이용하여 하중재하기간을 1일, 2일, 4일, 8일 등으로 달리한 표준압밀시험을 실시하였다. 그리고 인천, 광양, 울산지역의 불교란 시료에 대한 압밀시험도 같이 수행하여 소성지수와 압밀하중재하기간이 2차 압밀에 어떤 영향이 있는지를 밝혔다. 그리고 각 소성지수에 따른 하중과 침하특성, 압밀계수특성, 압축지수 및 2차 압축지수특성, 간극수압특성을 밝히고 압축지수, 압밀계수, 2차 압축지수 등을 소성지수, 하중에 관하여 정식화하였다. 또한 정식화한 식을 이용한 1차 및 2차 압밀침하량 예측결과와 탄소성 구성모델인 수정 Cam-Clay모델과 탄 점소성 모델인 Sekiguchi모델을 이용한 예측결과를 모형시험 결과와 같이 비교하였다. 그 결과, 2차 압밀특성을 고려한 Sekiguchi모델이 매우 정도 높게 결과를 예측할 수 있음을 알 수 있었다.

Numerical and experimental study of large deflection of symmetrically laminated composite plates in compression

  • Chai, Gin Boay;Hoon, Kay Hiang
    • Structural Engineering and Mechanics
    • /
    • 제2권4호
    • /
    • pp.359-367
    • /
    • 1994
  • The stability behaviour of symmetrically laminated rectangular composite plates with loaded ends clamped and unloaded edges simply-supported, and subjected to uniform in-plane compression is investigated. A numerical and experimental investigation is presented in this contribution. The stacking sequence of the laminated glass/epoxy composite plates is symmetric about the middle surface and consists of 8-ply [0, 90, +45, -45]s lamination. Numerical predictions were obtained through the use of the finite element method. The above plates were modelled with 8-noded isoparametric layered shell elements. The effect of the input parameters such as the degree and forms of prescribed initial imperfection and the incremental step size required for incremental loading, on the convergence of the solution is thoroughly examined. Experimental results are presented for 10 test panels. All test panels were made from glass/epoxy unidirectional prepregs and have aspect ratio of 5.088. The laminate thicknesses were found to vary from 1.054 mm to 1.066 mm. Comparison of experimental data with predicted results show good correlation and give confidence in the finite element model.

고감쇠고무와 강재슬릿의 복합 댐퍼로 보강한 건축물의 해석적 성능평가 (Analytical Performance Evaluation of Structure Reinforced with HRS Damper)

  • 김유성;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.