• Title/Summary/Keyword: Inclined Plane

Search Result 207, Processing Time 0.03 seconds

The Characteristics of Stress Distribution on Two-arch Tunnel's Pillar due to Surface Loads in the Discontinuous Rock Mass (불연속성 암반에 위치한 2-아치 터널에서 지표면 하중 작용시 필러에 전달되는 응력 특성)

  • Kim, Hong-Moon;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.5
    • /
    • pp.65-73
    • /
    • 2009
  • Large scale model tests and numerical analyses are performed to investigate the stress distribution of pillar due to surface loading nearby two-arch tunnel which is constructed in the regularly jointed rocks. It is observed that the influence of discontinuities on the stress distribution in the discontinuous rock mass and the underground stresses induced by surface loading are greater than those of linear elastic theory. Especially, lines of equal stresses are developed to the direction of inclination according to the inclined grade. In cases of discontinuities imbedded in parallel with or vertical to the ground, the pressure bulbs are formed symmetrically, however, the inclined ones result in stress distribution in parallel with and vertical to the planes of discontinuities. Results indicated that stress distribution is seriously affected by the angle of discontinuity. When stresses propagating to the pillar need to be estimated, relative location of surface loading, grade of discontinuous plane, and location of two-arch tunnel should be carefully considered.

A study on the occlusal wear patterns in maxillary posterior teeth with palatal side abfractions (구개측 굴곡파절이 있는 상악 구치의 교합면 마모 양상에 대한 연구)

  • Song, Joo-Hun;Kim, Hee-Jung;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.153-159
    • /
    • 2019
  • Purpose: Aims to analyze the occlusal wear patterns in maxillary posterior teeth with palatal side abfractions and study the association between occlusal force and abfractions. Materials and Methods: This study was conducted in a total of 308 teeth from 148 patients with palatal side abfractions in maxillary posterior teeth. The occlusal wears in maxillary premolars and molars with palatal side abfractions were classified and recorded. The classification was done by type of teeth, age, and gender, and in order to evaluate the statistical significance between groups, chi-square test was conducted (${\alpha}=0.05$). Results: Palatal side abfractions in maxillary posterior teeth were observed at the highest frequency in the 1st molars, and in all teeth with palatal side abfractions, more than one occlusal wear was observed. In classification by type of teeth, by age, and by gender, the occlusal wears in teeth with palatal side abfractions were observed at high frequency in cuspal inclined plane, central fossa, and marginal ridge, and there was a statistical significance (P < 0.05). Conclusion: Palatal side abfractions were observed at the highest frequency in maxillary 1st molars, and in all maxillary posterior teeth where palatal side abfractions were found, the occlusal wears were observed. And the occlusal wears were observed at high frequency in cuspal inclined plane, central fossa and marginal ridge. Such results show that abfraction is associated with occlusal force.

The Angulation and Inclination of Individual Tooth to FH Plane in Normal Occlusion (정상교합자의 안이평면에 대한 개개 치아의 순, 협설측경사와 근원심경사)

  • Hwang, Hae-Sang;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.791-802
    • /
    • 1998
  • The purpose of this study was to obtain the angulation and inclination of FACC of all teeth to FH plane. Study models of 31 persons with normal occlusion were selected and mounted on the semiadjustable articulator for this study. Using T.A.R.G. with a little modified method, the angulation and inclination of FACC of all teeth to FH plane were measured and then the measurements were analyzed statistically. The obtained results were as follows. Mean, standard deviation, maximum value, and minimum value of the angulation and inclination of FACC of upper and lower teeth were obtained. $\cdot$The FACC in both upper and lower arch was progressively lingually-inclined from anterior teeth to posterior teeth. $\cdot$In the angulations of FACC of upper teeth, central and lateral incisor showed similar value. Yet, the FACC of the rest was progressively distally-angulated from the canine to posterior teeth. The FACC in lower arch was progressively mesially-angulated from anterior teeth to posterior teeth. $\cdot$The angulation and inclination of FACC of any tooth in both upper and lower teeth correlated strongly and positively with the angulation and inclination of FACC of adjacent tooth.

  • PDF

A ROENTGENOCEPHALOMETRIC STUDY ON MANDIBULAR PROGNATHISM (하악(下顎) 전돌증(前突症)에 관(關)한 방사선(放射線) 두부계측학적(頭部計測學的) 연구(硏究))

  • Lee, Ki Soo
    • The korean journal of orthodontics
    • /
    • v.9 no.1
    • /
    • pp.85-98
    • /
    • 1979
  • This investigation was designed to compare the craniofacial and dental morphology of class III malocclusion with that of normal occlusin in children, and to determine the incidence of various class III craniofacial skeletal patterns. The material selected for this study consisted in standard lateral cephalograms of eighty two Korean children, forty one boys and forty one girls, aged 10 through 12 years, having class III malocclusion, and forty two Korean children, twenty boys and twenty two girls, with normal occlusion in the same age. Using the tracings of the standard lateral cephalograms, various angular and linear measurements were recorded, tabulated and statistically analyzed, and then the class III craniofacial skeletal morphology was divided into various patterns by the degree of SNA and SNB, which respectively were below, within or beyond the normal range of those of normal occlusion. The following characteristics of the craniofacial and dental morphology of class III malocclusion were observed. 1. The cranial base length of class III malocclusion was smaller than that of normal occlusion, and the small saddle angle was a characteristic figure of class III malocclucion. 2. Maxillary length of class III malocclusion was smaller than that of normal occlusion, and point A was retropositioned relative to cranial base but not PNS in class III malocclusion. Maxillary base inclination was not significantly different between the two, but occlusal plane to palatal plane was small in class III malocciusion. 3. The mandibular body length shown no difference between the two, but the mandibular body positioned anteriorly relative to cranial base in class III malocclusion. Ramus height, gonial angle, and mandibular effective length were large in class III malocclusion. Mandibular plane angle and joint angle had no difference between the two, and occlusal plane to mandibular plane angle was large in class III malocclusion. 4. Maxillary incisor inclination was not significantly different between class III malocclusion and normal occlusion, but mandibular incisors positioned and inclined lingually and consequently interincisal angle was large in class III malocclusion. 5. Class III malocclusion was divided into six categories of craniofacial skeletal pattern. The most common class III pattern was found to be one in which the maxilla was within the normal range of prognathism while the mandible extended beyond this range. The pattern in which the maxilla was below the normal range of prognathism while the mandible was within this range was approximately one fifth of the class III sample.

  • PDF

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

Natural frequency of a composite girder with corrugated steel web

  • Moon, Jiho;Ko, Hee-Jung;Sung, Ik Hyun;Lee, Hak-Eun
    • Steel and Composite Structures
    • /
    • v.18 no.1
    • /
    • pp.255-271
    • /
    • 2015
  • This paper presents the natural frequency of a composite girder with corrugated steel web (CGCSW). A corrugated steel web has negligible in-plane axial stiffness, due to the unique characteristic of corrugated steel webs, which is called the accordion effect. Thus, the corrugated steel web only resists shear force. Further, the shear buckling resistance and out-of-plane stiffness of the web can be enhanced by using a corrugated steel web, since the inclined panels serve as transverse stiffeners. To take these advantages, the corrugated steel web has been used as an alternative to the conventional pre-stressed concrete girder. However, studies about the dynamic characteristics, such as the natural frequency of a CGCSW, have not been sufficiently reported, and it is expected that the natural frequency of a CGCSW is different from that of a composite girder with flat web due to the unique characteristic of the corrugated steel web. In this study, the natural frequency of a CGCSW was investigated through a series of experimental studies and finite element analysis. An experimental study was conducted to evaluate the natural frequency of CGCSW, and the results were compared with those from finite element analysis for verification purpose. A parametric study was then performed to investigate the effect of the geometric characteristics of the corrugated steel web on the natural frequency of the CGCSW. Finally, a simplified beam model to predict the natural frequency of a CGCSW was suggested.

Effects of interface delay in real-time dynamic substructuring tests on a cable for cable-stayed bridge

  • Marsico, Maria Rosaria
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1173-1196
    • /
    • 2014
  • Real-time dynamic substructuring tests have been conducted on a cable-deck system. The cable is representative of a full scale cable for a cable-stayed bridge and it interacts with a deck, numerically modelled as a single-degree-of-freedom system. The purpose of exciting the inclined cable at the bottom is to identify its nonlinear dynamics and to mark the stability boundary of the semi-trivial solution. The latter physically corresponds to the point at which the cable starts to have an out-of-plane response when both input and previous response were in-plane. The numerical and the physical parts of the system interact through a transfer system, which is an actuator, and the input signal generated by the numerical model is assumed to interact instantaneously with the system. However, only an ideal system manifests a perfect correspondence between the desired signal and the applied signal. In fact, the transfer system introduces into the desired input signal a delay, which considerably affects the feedback force that, in turn, is processed to generate a new input. The effectiveness of the control algorithm is measured by using the synchronization technique, while the online adaptive forward prediction algorithm is used to compensate for the delay error, which is present in the performed tests. The response of the cable interacting with the deck has been experimentally observed, both in the presence of delay and when delay is compensated for, and it has been compared with the analytical model. The effects of the interface delay in real-time dynamic substructuring tests conducted on the cable-deck system are extensively discussed.

Evaluation of Masseter Muscle Activity by Occlusal tooth Contact Patterns (교합접촉 형태에 따른 교근활성의 평가)

  • Kim, Hee-Jung;Kim, Jin-A;Min, Jeong-Bum;Oh, Sang-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.11-19
    • /
    • 2007
  • There are have been reports that the distribution of electromyographical(EMG) activity is determined in a predictable manner by both the location and number of occlusal contacts. However, these reports placed an emphasis on whole dentition. Inclined plane contacts in the frontal plane are classified as A-, B- or C-types. Objectives: The aim of this study was to evaluate the relation between occlusal tooth contact patterns and EMG activity of masseter muscle during maximum voluntary clenching. Methods: Fifteen healthy human subjects(Mean age; 25.3 years) volunteered to participate in this study. Acrylic resin overlays were fabricated for upper 2nd premolars and 1st molars bilaterally, and offered 3 types(A-, B- and AB- type contact). EMG activity of the masseter muscles was recorded bilaterally during maximum voluntary clenching. Statistical analysis was performed using the one-way ANOVA. Results: The group with a A-type contact showed a statistically lower EMG activity of masseter muscle than that of natural group(p<0.05) and that of B- and AB- type groups(p<0.01) on both upper 2nd premolars and upper 1st molars. Conclusions: These results suggest that occlusal tooth contact patterns have an influence on EMG activity of masseter muscle during maximum voluntary clenching.

THE BEAM POINTING OF COMMUNICATIN SATELLITE IN GEOSYNCHRONOUS INCLINED ORBIT (궤도경사각을 가진 통신위성의 빔 포인팅에 대한 연구)

  • 김방엽;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.112-122
    • /
    • 1995
  • We assume that the KOREASAT fails the entry of the geostationary orbit due to the error at the apogee kick motor firing. A simulation is done for the satellite that has a geosynochronous orbit with a non-zero degree inclination angle due to the failure at the apogee kick motor firing caused by the unbalance of the fuel storage and the spin of the thrust vector, etc. We analyzed the evolution of the orbit using the perturbation theory and calculated the changes of the eccentricity and the inclination. WHen a communication satellite has the figure eight trajectory, the beam point also traces the satellite. In this paper, We develope an algorithm to attack the above problem by stabilizing the beam point using the adjustment of the roll angle of the satellite. The spin action on the polarization plane that occurs when a satellite passes the ascending node and descending node affects the efficiency of the communication a lot, so we did another simulation for the better yaw angle adjustment for the KOREASAT to reduce the spin actino on the polarization plane.

  • PDF

Full mouth rehabilitation of a patient with occlusal plane discrepancy with milling machine for clinic (진료실용 밀링머신을 이용한 교합평면 부조화 환자의 완전 구강 회복술)

  • Park, Ji-Man
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.68-78
    • /
    • 2016
  • Recently, digital technology has become increasingly prevalent in the dental clinic. Using a milling machine for clinic, it is possible to produce provisional restoration inside the clinic. This can promote large clinical cases such as full mouth rehabilitation with the help of a tabletop scanner, which is capable of semi-adjustable articulator equipment, and a powerful dental CAD software with excellent user convenience. In this case report, a full-mouth rehabilitation was done with digital technology to a 55 year-old female patient, who has lost vertical dimension through the attrition, and has got inclined occlusal plane with unplanned and repeated dental reconstruction. Through the design and milling of the provisional restoration in the clinic and the duplication of these provisionals by double scanning technique, a good functional and esthetic result could be achieved.