• Title/Summary/Keyword: Incident rate

Search Result 333, Processing Time 0.028 seconds

Dynamic Shear Stress of Tough-Pitch Copper at High Strain and High Strain-Rate

  • Moon, Wonjoo;Seo, Songwon;Lim, Jaeyoung;Min, Oakkey
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1412-1419
    • /
    • 2002
  • Dynamic shear tests for the tough-pitch copper at high strain and high strain rate was performed. The Split Hopkinson Pressure Bar (SHPB) compression test system was modified to yield a shear deformation in the specimen. Hat-shaped specimens for the tough-pitch copper were adopted to generate high strain of γ=3~4 and high strain-rate of γ= 10$^4$/s. The dynamic analysis by ABAQUS 5.5/EXPLICIT code verified that shear zone can be localized in hat-shaped specimens. A proper impact velocity and the axial length of the shear localization region wert determined through the elastic wave analysis. The displacement in a hat-shaped specimen is limited by a spacer ring which was installed between the specimen and the incident bar. The shear bands were obtained by measuring the direction of shear deformation and the width of deformed grain in the shear zone. The decrease of specimen length has been measured on the optical displacement transducer. Dynamic shear stress-strain relations in the tough-pitch copper were obtained at two strain-rates.

A Comparison of the Cancer Incidence Rates between the National Cancer Registry and Insurance Claims Data in Korea

  • Seo, Hee Jung;Oh, In-Hwan;Yoon, Seok-Jun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6163-6168
    • /
    • 2012
  • Although much health services research has been conducted using national health insurance claims data in Korea, the validity of this method has not been ascertained. The objective of this study was to validate the use of claims data for health services research by comparing incidence rate of cancers found using insurance claims data against rates of the national cancer registry of Korea. An algorithm to estimate incidence rates using claims data was developed and applied. The claims data from 2005-2008 were acquired and the patients admitted to hospitals due to cancer in 2008 without admission to hospital from 2005-2007 by the same diagnosis code were regarded as incident cases. The acquired results were compared with the values from the National Cancer Registry of Korea. The incidence rate of all cancers found using claims data was 363.1 per 100,000 people, which is very similar to the 361.9 per 100,000 rate of the national cancer registry. Also the age-, gender- and disease-specific rates between the two data sources were similar. Therefore, national health insurance claims data may be a worthwhile resource for health services research if appropriate algorithms are applied, especially considering the cost effectiveness of this method.

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

Ion Flux Assisted PECVD of SiON Films Using Plasma Parameters and Their Characterization of High Rate Deposition and Barrier Properties

  • Lee, Joon-S.;Jin, Su-B.;Choi, Yoon-S.;Choi, In-S.;Han, Jeon-G.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.236-236
    • /
    • 2011
  • Silicon oxynitride (SiON) was deposited for gas barrier film on polyethylene terephthalate (PET) using octamethylycyclodisiloxane (Si4O4C8H24, OMCTS) precursor by plasma enhanced chemical vapor deposition (PECVD) at low temperature. The ion flux and substrate temperature were measured by oscilloscope and thermometer. The chemical bonding structure and barrier property of films were characterized by Fourier transform infrared (FT-IR) spectroscopy and the water vapor transmission rate (WVTR), respectively. The deposition rate of films increases with RF bias and nitrogen dilution due to increase of dissociated precursor and nitrogen ion incident to the substrate. In addition, we confirmed that the increase of nitrogen dilution and RF bias reduced WVTR of films. Because, on the basis of FT-IR analysis, the increase of the nitrogen gas flow rate and RF bias caused the increase of the C=N stretching vibration resulting in the decrease of macro and nano defects.

  • PDF

CQI Action Team Approach to Prevent Pressure Sores in Intensive Care Unit of an Acute Hospital Korea (중환자의 욕창 예방 연구 : 욕창 예방 QI팀을 중심으로)

  • Kang, So Young;Choi, Eun-Kyung;Kim, Jin-Ju;Ju, Mi-Jung
    • Quality Improvement in Health Care
    • /
    • v.4 no.1
    • /
    • pp.50-63
    • /
    • 1997
  • Background : A pressure sore was defined as any skin lesion caused by unrelieved pressure and resulting in damage to underlying tissue. The health care institutions in the United States were reported the incident rate of pressure sores ranging from 6 to 14 %. Intensive Care Unit needed highest quality of care has been found over 40% incidence rate of pressure sore. Also, Annual expenditures for the care of pressure sores in patients in the United States have been estimated to be $7.5 billion; furthermore, 50 percent more nursing time is required to care for patients with pressure sore in comparison to the time needed to implement preventive measures against pressure sore formation. However, In Korea, there were little reliable reports, or researches, about incidence rates of pressure sore in health care institution including intensive care unit and about the integrated approach like CQI action team for risk assessment, prevention and treatment of pressure ulcers. Therefore, this study was to develop pressure sore risk assessment tool and the protocol for prevention of pressure sore formation through CQI action team activities, to monitor incident rate of pressure sore and the length of sore formation for patients at high risk, and to approximately estimate nursing time for sore dressing during research period as the effect of CQI action team. Method : CQI action team in intensive care unit, launched since early 1996, reviewed the literature for the standardized risk assessment tool, developed the pressure sore assessment tool based on the Braden Scale, tested its validity, compared on statistics including incidence rate of pressure sore for patients at high risk. Throughout these activities, CQI action team was developed the protocol, called as St. Marys hospital Intensive Care Unit Pressure Sore Protocol, shifted the emphasis from wound treatment to wound prevention. After applied the protocol to patients at high risk, the incident rate and the period of prevention against pressure development were tested with those for patients who received care before implementation of protocol by Chi-square and Kaplan-Meier Method of Survival Analysis. Result : The CQI action team found that these was significant difference of in incidence rate of pressure sores between patients at high risk (control group) who received care before implementation of protocol and those (experimental group) who received it after implementation of protocol (p<.05). 25% possibility of pressure sore formation was shown for the patients with 6th hospital day in ICU in control group. In experimental group, the patients with 10th hospital day had 10% possibility of pressure sore. Therefore, there was significant difference(p<.05) in survival rate between two groups. Also, nursing time for dressing on pressure sore in experimental group was decreased as much as 50% of it in control group. Conclusion : The collaborative team effort led to reduced incidence, increased the length of prevention against pressure sore, and declined nursing care times for sore dressing. However, there have had several suggestions for future study. The preventive care system for pressure sore should be applied to patients at moderate, or low risk throughout continuous CQI team activities based on Bed Sore Indicator Fact Sheet. Hospital-wide supports, such as incentives, would be offered to participants for keeping strong commitment to CQI team. Also, Quality Information System monitoring incidents and estimating cost of poor quality, like workload (full time equivalence) or financial loss, regularly in a hospital has to be developed first for supporting CQI team activities as well as empowering hospital-wide QI implementation. Being several limitations, this study would be one of the report cards for the CQI team activities in intensive care unit of an acute hospital and a trial of quality improvement of health care in Korea.

  • PDF

Development of Incident Detection Model Using Compression Wave Test Module (압축파 검사 모듈을 이용한 돌발상황 검지 모형의 개발)

  • Lee, Hwan-Pil;Kim, Nam-Sun;Oh, Young-Tae;Kim, Soo-Hee
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.6
    • /
    • pp.77-88
    • /
    • 2004
  • This study aims at developing the model that is able to detect the compression wave, which is included as a similar situation in incidents, that causes false applicable to the similar character such as incidents in the incident detection model for expressways. In this study, it has been checked whether the number of false alarms is decreased or not by modularizing this model for being able to applicable to other models such as DES and DELOS, etc. which do not perform the compression wave test based on the compression wave test process of APID model which has been being used in the expressway traffic management system currently. The evaluation in this study focuses on the sensitivity of the model and the results analysis is performed classified by each polling cycle. And how well these models are working is evaluated by each polling cycle. In addition to this, the detection rate, the false alarm rate and the average detection time in both the existing models and the model in this study are calcuated. As a result of appling the model in this study, it is found that the false alarm rate is improved through the reasonable decrease in the number of false alarm frequencies and there are not remarkable changes concerning the detection rate and the average detection time. To sum up, it is expected that a good number of improvement effects will be occurred when this model is applied to the actual expressway traffic management system.

Occupational Injury Statistics in Korea

  • Kang, Seong-Kyu;Kwon, Oh-Jun
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.52-56
    • /
    • 2011
  • Objectives: The occupational accident rate was officially reported to be 0.77 per 100 workers in 2001 and 0.70 in 2009. The stagnant decrease in accident rate raises a question about the effectiveness of prevention activity because there have been active prevention efforts in the past 10 years. It is also necessary to know the exact status of occupational injuries to direct a prevention strategy. Methods: The author re-analyzed occupational injury statistics to find the reason for stagnant decreases in occupational injuries. Compensated occupational injuries cases were used to calculate fatal and non-fatal injury rates. Injuries from commuting accidents and sports activities were excluded as well as occupational diseases. The number of workers was adjusted to that of full time equivalent employees. Results: The fatal injury rate excluding injuries associated with commuting accidents, sports activities, and occupational diseases decreased from 12.59 in 2001 to 8.20 in 2009. In 2007, 67.5% of accidents that involved being caught in objects, which are mostly caused by machines and equipment, occurred in the manufacturing industry; this type of incident has decreased since 2001. The fatal and non-fatal injury rates in the manufacturing industry have continuously decreased while the rates in the service industry have not changed from 2001 to 2009. Non-fatal injuries might not be reported in many cases. The number of insured workers was underestimated as long working hours were not adjusted for in the reporting system. Conclusion: The occupational fatal injury rate has decreased and the non-fatal injury rate might have decreased during the last 10 years, although the statistics show stagnancy. The decrease of the injury rate was countervailed by various factors. Hence, the current accident rate does not reflect the actual situation of accidents in Korea. Korea needs to develop an improved system to more accurately calculate occupational fatal and non-fatal injury rates.

Developing a Smart Pillbox to Improve the Medication Adherence of the Patients Requiring a Long-term administration (장기 투약대상자의 약물순응도를 높이기 위한 스마트 약상자의 구현)

  • Kim, Beom-Joon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.4
    • /
    • pp.611-617
    • /
    • 2013
  • Although tuberculosis can be recovered if patients take medicine consistently, Korea shows significantly high rate in terms of incident rate and death rate of the tuberculosis patients. Considering such a situation, this paper has developed a smart pillbox that facilitates for patients requiring a long-term administration to take medicine in a regular and consistent manner. The developed smart pillbox is equipped with a load cell that can measure the weight in unit of 0.1g so that it can determine whether or not the medicine is dispensed out of itself. In addition, a software has been developed to determine the status of patient's taking medicine based on the measurement result.

High Cell Density Culture of Anabaena variabilis with Controlled Light Intensity and Nutrient Supply

  • Yoon, Jong-Hyun;Shin, Jong-Hwan;Ahn, Eun-Kyung;Park, Tai-Hyun
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.5
    • /
    • pp.918-925
    • /
    • 2008
  • Controlling the light energy and major nutrients is important for high cell density culture of cyanobacterial cells. The growth phase of Anabaena variabilis can be divided into an exponential growth phase and a deceleration phase. In this study, the cell growth in the deceleration phase showed a linear growth pattern. Both the period of the exponential growth phase and the average cell growth rate in the deceleration phase increased by controlling the light intensity. To control the light intensity, the specific irradiation rate was maintained above $10\;{\mu}mol/s/g$ dry cell by increasing the incident light intensity stepwise. The final cell density increased by controlling the nutrient supply. For the control of the nutrient supply, nitrate, phosphate, and sulfate were intermittently added based on the growth yield, along with the combined control of light intensity and nutrient concentration. Under these control conditions, both final cell concentration and cell productivity increased, to 8.2 g/l and 1.9 g/l/day, respectively.

Experiment Research of Autonomous Driving Valve for Pulse Detonation Rocket Engine

  • Matsuoka, Ken;Yamaguchi, Hiroyuki;Nemoto, Toyoshi;Yageta, Jun;Kasahara, Jiro;Yajima, Takashi;Kojima, Takayuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.419-426
    • /
    • 2008
  • As pulse detonation engine(PDE) does not need compression mechanisms such as compressors because self-sustained detonation waves are able to compress propellant gases by their incident shock waves, the PDE can have a simple straight-tube structure. In this study, we propose an autonomous driving valve system of the PDE, which fill premixed gases into the PDE tubes at high frequency with high mass flow rate. The proposed valve is composed of only three parts: a piston, a cylinder, and a spring. This valve system can produce intermittent flow at high mass flow rate, and also can keep stable reciprocal motion by using the propellant-gas enthalpy. When the cylinder content product is assumed to be constant, experimental results of the mass flow rate were approximately equal to the calculation model. We confirmed the autonomous driving valve performance by experiments, and concluded that this extremely simple valve with no electrical power and controller can be used as the PDE propellant supply system.

  • PDF