• 제목/요약/키워드: In-tube

검색결과 10,236건 처리시간 0.039초

Development of Manufacturing Method of Vessel for Keeping Warm by Hydraulic Bulging

  • Chung, Joon-Ki;Cho, Woong-Shick
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권4호
    • /
    • pp.40-46
    • /
    • 2001
  • Bulging is a forming method to shape die cavity by using hydraulic pressure in tube or vessel. Bulging machine and die were developed in order to produce vessel for keeping warm. Bulging machine is a double type with two horizontal cylinders for bulging of two pieces at the same time. The developed die system has one bulging die and two drawing dies for necking at both ends of the tube. The diameter of tube expands by hydraulic pressure in tube. At the same time, thrust at both ends of the tube pushes tube in the direction of expansion to obtain high expansion rate with no crack. In this study, the bulging properties were investigated to solve tube crack and necking in manufacturing vessel by combining bulging and drawing. As a result, high expanding rate of tube radius without crack, precision necking and high productivity were obtained.

  • PDF

Damage to the pilot balloon of the nasotracheal tube during orthognathic double-jaw surgery: A case report

  • Kim, Eun-Jung;Yoon, Ji-Young;Woo, Mi-Na;Kim, Cheul-Hong;Yoon, Ji-Uk;Jeon, Da-Nee
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제15권2호
    • /
    • pp.101-103
    • /
    • 2015
  • In oral and maxillofacial surgery, many complications associated with nasotracheal tube can be caused. In this case, we reported ballooning tube damage of nasotracheal tube during orthognathic double-jaw surgery and replacement of tube through cut down of tube and tube exchange using airway exchange catheter. The patient scheduled for high Le Fort I osteotomy and bilateral sagittal split osteotomy was intubated nasotracheally with nasal endotracheal tube. During maxilla osteotomy, air bubble was detected in the oral blood. In spite of our repeated ballooning, the results were the same so we changed damaged tube using airway exchange catheter aseptically. Tiny and superficial cutting site was detected in the middle of pilot tube. As we know in our case, tiny injury impeded a normal airway management and prevention is important.

튜브 트레인 공력특성 해석 (Aerodynamic Characteristics of a Tube Train)

  • 김태경;김규홍;권혁빈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.139-150
    • /
    • 2010
  • 최근 한국에서는 세계적인 녹색기술을 맞아 향후 차세대 교통 시스템으로서 튜브 트레인 시스템의 본격적인 연구가 진행되고 있다. 한국 철도기술연구원(KRRI, Korea Railroad Research Institute)에서 튜브 트레인 시스템의 건설을 위한 목적으로 연구가 진행되고 있다. 본 논문에서는 기초연구의 일환으로 축대칭하며 긴 형상의 수송체가 가지는 다양한 튜브(터널) 내부의 압력, 막힘비율, 운행속도를 파라미터로 선정하여 전산해석을 수행하였다. 세부사항으로는 동일 형상의 운송체가 동일 운행속도를 가지고 일반적 압력의 개활지(오픈 시스템, 개활지 운행)를 운행할 때와, 다양한 환경(튜브 내 압력, 막힘비율, 운행속도)의 튜브 내부를 운행할 때에 대하여 튜브 트레인의 공력특성 연구를 수행하였다. 이를 통하여 다양한 운행속도-막힘비율 별로 개활지와 동일 에너지 효율 나오는 튜브 내 압력(P-D 관계)을 계산하였고, 막힘비율 증가에 따른 튜브 내 감압 정도(P-${\beta}$ 관계), 다양한 막힘비율-튜브 내 압력 별로 운행속도에 따른 전체 항력 양상(D-V 관계)을 보여 주었다. 그리고 개활지 운행시와 튜브 내부 운행시의 에너지 효율(주행저항)을 비교하였고, 튜브 내부 운행 시 트레인이 갖는 효율과 관계되는 충격파 발생의 임계속도(critical V-B 관계) 및 한계속도(V-P 관계)를 얻을 수 있었다. 이러한 연구의 결과는 튜브 시스템 설계 및 건설에 꼭 필요한 것이며 가이드라인을 제시했다.

  • PDF

R22 대체 냉매의 마이크로 핀관내 흐름 비등 열전달 특성 (Flow Boiling Heat Transfer Characteristics of R22 Alternative Refrigerants in a Horizontal Microfin Tube)

  • 한재웅;김신종;정동수;김영일
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.692-700
    • /
    • 2001
  • Flow boiling heat transfer coefficients(HTCs) of R22, R134a, R407C, and R410A were measured experimentally for a horizontal plain and a microfin tube. Experimental apparatus was composed of 3 main parts: a refrigerant loop, a water loop and a water-glycol loop. The test section in th refrigerant loop was made of a copper tube of 9.52 mm outer diameter and 1 m length for both tubes. The refrigerant was heated by passing hot water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $5^{\circ}C$ with mass fluxes of 100~300 kg/$m^2$s. Test results showed that at similar mass flux the flow boiling HTCs of R134a were similar to those of R22 for both plain and microfin tube. HTCs of R407C were similar to those of R22 for a plain tube but lower than those of R2 by 25~48% for a microfin tube. And HTCs of R410A were higher than those of R2 by 20~63% for a plain tube and were similar to those of R22 for a microfin tube. In general, HTCs of a microfin tube were 1.8~5.7 times higher than those of a plain tube.

  • PDF

삼차원 재건 기술을 이용한 맞춤형 몽고메리 T-Tube의 제작에 관한 예비 연구 (Custom-Made T-Tube Designed by 3-D Reconstruction Technique, a Preliminary Study)

  • 유영삼
    • 대한기관식도과학회지
    • /
    • 제16권2호
    • /
    • pp.131-137
    • /
    • 2010
  • Background: Montgomery T-tube is widely used to maintain airway in many cases. Market-available tubes are not always fit to the trachea of each patient and need some modification such as trimming. Complications do happen in prolonged use like tracheostomy tubes. To overcome above limitations, we designed custom-made T-tube using CT data with the aid of 3D reconstruction software. Material and Method: Boundaries were extracted from neck CT data of normal person and processed by surface rendering methods. Real laryngotracheal model and tracheal inner surface-mimicking tube model were made with plaster and rubber. The main tube was designed by accumulation of circles or simple closed curves made from boundaries. Stomal tube was made by accumulation of squares due to limitation of software. Measurement data of tracheal lumen were used to custom-made T-tubes. Tracheal lumen residing portion (vertical limb) was made like circular cylinder or simple closed curved cylinder. Stomal portion (horizontal limb) was designed like square cylinder. Results: Custom made T-tube with cylindric vertical limb and horizontal limb of square cylinder was designed. Conclusion: CT data was helpful in making custom made T-tube with 3D reconstruction technique. If suitable materials are available, commercial T-tube can be printed out from 3D printers.

  • PDF

MF증발기 기초 형상 설계에 관한 연구 (A Study on the Basic Shape of an MF Evaporator)

  • 박용석;성홍석;서정세
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성 (Axial Crush and Energy Absorption Characteristics of Aluminum/GFRP Hybird Square Tubes)

  • 김구현;이정주;신금철
    • 한국자동차공학회논문집
    • /
    • 제8권6호
    • /
    • pp.208-219
    • /
    • 2000
  • In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tube. Glass/Epoxy prepregs were wrapped around an aluminum tube and co-cured. The failure of the hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to the maximum of 33% in comparison with the aluminum tube. Effective energy absorption is possible for an inner aluminum tube because a wrapped composite tube constrains the deflection of an aluminum tube. The failure of a hybrid composite tube was stable without trigger mechanism because the inner aluminum tube could play the role of the crack initiator and controller. Mean crushing load could be calculated by modifying the plastic hinge collapse model for hybrid materials. The predicted results by this analytical model showed good agreement with the experimental results. It can be said that Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure because this hybrid tube shows effective energy absorption, easy production, and simple application capability for RTM process.

  • PDF

하부폐쇄 환상공간의 외부 튜브길이가 풀비등에 미치는 영향 (Effects of Outer Tube Length on Pool Boiling in an Annulus with Closed Bottoms)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.749-755
    • /
    • 2006
  • To improve pool boiling heat transfer in an vertical annulus with closed bottoms, the length of an outer tube has been changed from 0.2m to 0.6m. For the test, a heated tube of 19.1mm diameter and water at atmospheric pressure have been used. Annular conditions are made using glass tubes fabricated around the heated tube. The gap size of the annulus is 3.65mm. To elucidate effects of the outer tube length on heat transfer results of the annulus are compared with the data of a single unrestricted tube and the annulus with wider gap size of 6.35mm. Throughout the tests much higher heat transfer coefficients are observed for the annulus of 3.65mm gap size comparing to the other two cases. The change in the outer tube length results in much variation in heat transfer coefficients. Moreover, with shortening the length of outer tube the possibility of the CHF occurrence can be removed.

Simulation and Analysis of ECT Signals Obtained at Tubesheet and Tube Expansion Area

  • Song, Sung-Chul;Lee, Yun-Tai;Jung, Hee-Sung;Shin, Young-Kil
    • 비파괴검사학회지
    • /
    • 제26권3호
    • /
    • pp.174-180
    • /
    • 2006
  • Steam generator (SG) tubes are expanded inside tubesheet holes by using explosive or hydraulic methods to be fixed in a tubesheet. In the tube expansion process, it is important to minimize the crevice gap between expanded tube and tube sheet. In this paper, absolute and differential signals are computed by a numerical method for several different locations of tube expansion inside and outside a tubesheet and signal variations due to tubesheet, tube expansion and operating frequencies are observed. Results show that low frequency is good for detecting tubesheet location in both types of signals and high frequency is suitable for sizing of tube diameter as well as the detection of transition region. Also learned is that the absolute signal is good for measuring tube diameter, while the differential signal is good for locating the top of tubesheet and both ends of the transition region. In the case of mingled anomaly with tube expansion and tubesheet, low frequency inspection is found to be useful to analyze the mixed signal.

나선코일 튜브 내에서의 압력손실에 관한 연구 (A Study on the Pressure Loss in Helically Coiled Tubes)

  • 한규일;박종운
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF