A Study on the Fluid Flow of Vortex Nozzle for Generating Micro-bubble (미세버블 발생용 보텍스 노즐의 유체유동에 대한 연구)

  • Yu, Seong-Hun;Park, Sang-Hee;Kang, Woo-Jin;Han, Seung-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.4_2
    • /
    • pp.637-644
    • /
    • 2022
  • In this study, the flow characteristics according to the shape of the vortex nozzle was studied by numerical analysis and the amount of microbubble generation was measured experimentally. The shape of the vortex nozzle is cylindrical, diffuser, and conical type. The axial fluid velocity in the induced tube gradually increased from the inlet to the outlet. In particular, the fluid velocity in the nozzle part increased rapidly. The velocity distribution of the fluid at the inlet of the induced tube showed that the flow rotates counterclockwise in the outer region and the inner center of the induced tube. At the outlet of the induced tube, the cylindrical and conical type showed rotational flow, and the diffuser type showed irregular turbulent flow. The dimensionless pressure ratio 𝜂 of the inner region of the induced tube was lower than that of the outer region. Also, 𝜂 near the outlet of the induced tube in cylindrical and conical type showed a similar tendency to the inlet area. At the outer region of inlet of induced tube, intense vorticity was observed on the wall and in lower region. At the inner region of inlet of induced tube, intense vorticity was observed on the inner wall of the induced tube and in the central region of the inlet of the induced tube. At the outlet of induced tube, in the case of the cylindrical and conical type, intense vorticity was observed near the inner wall, the diffuser type showed irregular strong vorticity inside the tube. The total number of bubbles measured was the most in the cylindrical type, and the microbubbles less than 50mm occurred the most in the conical type.

A study on the reduction of fuel consumption for fish farm during winter season (월동시 양식장의 연료 절감 대책)

  • Park, Jong-Un;Han, Kyu-Il
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.7 no.1
    • /
    • pp.31-43
    • /
    • 1995
  • For the fuel saving in the fish farm, the heat transfer performances of various tubes, XL-tube, copper-tube, copper-Nikel-tube and Al-brass-tube, were compared. The XL-tube, which is most commonly used for heating water, showed the poorest heater transfer performance, while the Al-Brass tube shows the best performance. As far as average temperature difference of four tubes concerns, XL-tube is $3.34^{\circ}C$, Copper tube is $10.34^{\circ}C$, Copper-Nikel tube is $11.3^{\circ}C$, Al-Brass-tube is $12^{\circ}C$, The best heat transfer performance of Al-Brass tube results from the enhancement of heat transfer coefficient caused by fin effect and good conductivity of the material.

  • PDF

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.

Anatomizing Popular YouTube Channels of English-speaking Countries

  • Han, Sukhee
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.42-47
    • /
    • 2020
  • YouTube, the online video streaming platform, has become popular and influential around the globe. Due to the development of science and technology, people without expertise in filming can now easily produce their videos with unique content. Many people are more eager to become a popular YouTube creator because they can earn money by placing commercials or Products in Placement (PPL) in their video clips. However, it is yet unknown what genres of YouTube videos are popular. YouTube creators have their channels where they upload videos of a certain type of genre. This study investigates video genres of the top 250 YouTube channels in English-speaking countries (United States, Canada, United Kingdom, and Australia) using Social Blade, which is a research website. The ranking is set based on the number of times people watched a video ("Video Views"). We handsomely analyze popular genres of the channels and also the YouTube ecosystem, and it will be meaningful for today's new media era.

An Experimental Study on the 1st Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (개방관형과 밀폐관형 열음향 냉동기의 1차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;정철진
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.189-192
    • /
    • 2002
  • In this study, The experimental open-tube-type and close-tube-type thermoacoustic refrigerator were constructed. The resonant characteristics of a thermoacoustic refrigerator were investigated. In order to determine the optimum resonant tube length and frequency, We changed the length of resonant tube from 400mm to 850mm and the frequency from 100Hz to 1000Hz. In case of first harmonic, the temperature difference of open-tube-type (1/4 wave) refrigerator was $41^{\circ}C$(resonator length :500mm). The temperature difference of close-tube-type (1/2 wave) refrigerator was $43^{\circ}C$(resonator length :850mm). In this experiments, the experimental 1/2 wave refrigerator is slightly cooler than the experimental l/4 wave refrigerator.

  • PDF

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

An Experimental Study of Ice-Making Performance on the Ice Storage System using Spiral Tube (관외착빙형 빙축열조의 제빙성능에 관한 연구)

  • Park, Yong-Joo;Yim, Kwang-Bin;Cho, Nam-Cheol
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • An experimental investigation was performed to compare ice making characteristics of ice storage system with smooth and spiral tube. During the freezing processes in the shell and tube type ice storage tank with smooth tube, heat resistance of the ice layer caused a decrease in freezing rate. Also, the phenomena of bridging made the increasing rate of ice making less. In order to improve the ice making rate, spiral tube(pitch=6mm) was used in the present study. The ice making rate and the decreasing of bridging for the spiral tube were higher than those for the smooth tube.

An Experimental Study on the Characteristics for Open-Tube and Close-Tube Thermoacoustic Effects(1) - The 1st Harmonic (개방관과 밀폐관의 열음향 효과에 관한 하모닉 특성 연구(1) - 1차 하모닉)

  • 송규조;이성노
    • Progress in Superconductivity and Cryogenics
    • /
    • v.4 no.1
    • /
    • pp.129-134
    • /
    • 2002
  • In this study, the experimental open-tube and close-tube thermoacoustic apparatuses were constructed. In order to determine the optimum length of resonant tube, frequency and the optimum length of stack, the resonant characteristics of thermoacoustic apparatuses were investigated, The length of resonant tube varies from 400mm to 850 mm. The experimental frequency varies from 100 Hz to 1000 Hz. In case of first harmonic, the maximum temperature difference of the open-tube thermoacoustic apparatus is 41$^{\circ}C$)resonator length: 500 mm), and the maximum temperature difference of the close-tube thermoacoustic apparatus is 42$^{\circ}C$ (resonator length : 850 mm).

A Method for Prediction of Tube Wear by Relative Displacement in the case of Inclined Contact between Tube & Support of Steam Generator (증기발생기에서 지지대와 세관의 경사면 접촉시 상대변위에 의한 세관 마모량 예측 방법)

  • Lee, Yong-Son;Park, Moon-Ghu;Kim, Tae-Soon;Park, Chi-Yong;Boo, Myung-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1168-1173
    • /
    • 2003
  • When the tube contacted to support and antivibration bar of the steam generator in unclear power plant, the contact area is worn out by their relative displacement. In the study, wear depths of the tube inclined to tube support and antivibration bar are approximately predicted by a method using the contact load and relative displacement. In the case of the inclined contact, the results show wear depths of the steam generator tube predicted by the impact model are larger than those by the sliding model.

  • PDF

Study on Transient Flow in Pipeline with Flexible Tube (탄성관을 삽입한 관로에서의 비정상류에 관한 연구)

  • Kim, Young-Joon;Tsukamoto, Hiroshi
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.825-828
    • /
    • 2005
  • Experimental and numerical study was done to confirm the effect of the flexible tube in pipeline on transient flow oscillation. Experiment was made for a pipeline with and without deformable flexible tube using a single pumping system of main stainless pipe. The wave speeds of main pipe and flexible tube were calculated from the pipe material properties, structures, and boundary conditions. Time dependent pressure fluctuations were calculated for the pipeline using the simple and the Kelvin-Voigt viscoelastic models for the deformation of main pipe and flexible tube. Pressure calculated by the Kelvin-Voigt viscoelastic model showed better agreement with measured one than pressure by the simple model. Experimental and numerical results show that the maximum pressure as well as amplitude of pressure oscillation was decreased by inserting short flexible tube in pipeline. Hence, inserted short flexible tube to pipeline was found to be effective for the suppression of strong pressure oscillation. Moreover, the wave speed in pipe was discussed based on numerical and experimental results.

  • PDF