• Title/Summary/Keyword: In-stent restenosis

Search Result 63, Processing Time 0.027 seconds

Intracoronary Radiation Therapy (관동맥혈관 내 방사선 근접 치료)

  • Moon, Dae-Hyuk;Park, Seong-Wook;Hong, Myeong-Ki;Oh, Seung-Jun;Bom, Hee-Seung;Lee, Hee-Kyung
    • 대한핵의학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.24-34
    • /
    • 2001
  • Restenosis remains a major limitation of percutaneous coronary interventions. Numerous studios including pharmacological approaches and new devices failed to reduce the restenosis rate except coronary stenting. Since the results of $BENESTENT^{1)}\;and\;STRESS^{2)}$ studies came out, coronary stenting has been the most popular interventional strategy in the various kinds of coronary stenotic lesions, although the efficacy of stenting was shown only in the discrete lesion of the large coronary artery. The widespread use of coronary stenting has improved the early and late outcomes after coronary intervention, but it has also led to a new and serious problem, e.g., in-stent restenosis. Intravascular radiation for prevention of restenosis is a new technology in the field of percutaneous coronary intervention. Recent animal experiments and human trials have demonstrated that local irradiation, in conjunction with coronary interventions, substantially diminished the rate of restenosis. This paper reviews basic radiation biology of intracoronary radiation and its role in the inhibition of restenosis. The current status of intracoronary radiation therapy using Re-188 liquid balloon is also discussed.

  • PDF

A Study on Optimal Shape of Stent by Finite Element Analysis (유한요소 해석을 이용한 스텐트 최적형상 설계)

  • Lee, Tae-Hyun;Yang, Chulho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.1-6
    • /
    • 2017
  • Stents are widely used as the most common method of treating coronary artery disease with implants in the form of a metal mesh. The blood flow is normalized by inserting a stent into the narrowed or clogged areas of the human body. In this study, the mechanical characteristics of a stent are investigated according to the variations of its design parameters by the Taguchi method and finite element analysis. A stent model of the Palmaz-Schatz type was used for the analysis. In the analysis, an elasto-plastic material model was adopted for the stent and a hyper-elastic model was used for the balloon. The main interest of this study is to investigate the effects of the design parameters which reduce the possibility of restenosis by adjusting the recoil amount. A Taguchi orthogonal array was constructed on the model of the stent. The thickness and length and angle of the slot were selected as the design parameters. The amounts of radial recoil and longitudinal recoil were calculated by finite element analysis. The statistical analysis using the Taguchi method showed that optimizing the shape of the stent could reduce the possibility of restenosis. The optimized shape showed improvements of recoil in the radial and longitudinal directions of ~1% and ~0.1%, respectively, compared to the default model.

Diagnostic Usefulness of High Resolution Cross Sectional MRI in Symptomatic Middle Cerabral Arterial Dissection

  • Lee, Hai-Ong;Kwak, Hyo-Sung;Chung, Gyung-Ho;Hwang, Seung-Bae
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.370-372
    • /
    • 2011
  • Dissection of the middle cerebral artery (MCA) is less frequent compared with dissection of the vertebrobasilar system or carotid artery. Recently, high-resolution cross sectional MR imaging (HRMRI) has emerged as a potential technique for atherosclerotic plaque imaging in MCA, We introduce the findings of HRMRI in a 56-year-old woman with traumatic MCA dissection, HRMRI showed an intimal flap and tapered pseudolumen with intra-luminal hemorrhage, We performed stent deployment about MCA dissection after failed medical treatment Three months later, there was no in-stent restenosis and no further neurological deficit were noted.

Hemodynamic Characteristics Affecting Restenosis after Percutaneous Transluminal Coronary Angioplasty with Stenting in the Angulated Coronary Stenosis

  • Lee, Byoung-Kwon;Kwon, Hyuck-Moon;Roh, Hyung-Woon;Cho, Min-Tae;Suh, Sang-Ho
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Backgrounds: The present study in angulated coronary stenosis was to evaluate the influence of velocity and wall shear stress (WSS) on coronary atherosclerosis, the changes of hemodynamic indices following coronary stenting, as well as their effect of evolving in-stent restenosis using human in vivo hemodynamic parameters and computed simulation quantitatively and qualitatively. Methods: Initial and follow-up coronary angiographies in the patients with angulated coronary stenosis were performed (n=80). Optimal coronary stenting in angulated coronary stenosis had two models: < 50 % angle changed(model 1, n=43), > 50% angle changed group (model 2, n=37) according to percent change of vascular angle between pre- and post-intracoronary stenting. Flow-velocity wave obtained from in vivo intracoronary Doppler study data was used for in vitro numerical simulation. Spatial and temporal patterns of velocity vector and recirculation area were drawn throughout the selected segment of coronary models. WSS of pre/post-intracoronary stenting were calculated from three-dimensional computer simulation. Results: Follow-up coronary angiogram demonstrated significant difference in the percent of diameter stenosis between two groups (group 1: $40.3{\pm}30.2$ vs. group 2: $25.5{\pm}22.5%$, p<0.05). Negative WSS area on 3D simulation, which is consistent with re-circulation area of velocity vector, was noted on the inner wall of post-stenotic area before stenting. The negative WSS was disappeared after stenting. High spatial and temporal WSS before stenting fell into within physiologic WSS after stenting. This finding was prominent in Model 2 (p<0.01) Conclusions: The present study suggests that hemodynamic forces exerted by pulsatile coronary circulation termed as WSS might affect on the evolution of atherosclerosis within the angulated vascular curvature. Moreover, geometric change, such as angular difference between pre / post-intracoronary stenting might give proper information of optimal hemodynamic charateristics for vascular repair after stenting.

  • PDF

Curcumin-Loaded PLGA Nanoparticles Coating onto Metal Stent by Electrophoretic Deposition Techniques

  • Nam, So-Hee;Nam, Hye-Yeong;Joo, Jae-Ryang;Baek, In-Su;Park, Jong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.397-402
    • /
    • 2007
  • Restenosis after percutaneous coronary intervention (PCI) continues to be a serious problem in clinical cardiology. To solve this problem, drug eluting stents (DES) with antiproliferative agents have been developed. Variable local drug delivery systems in the context of stenting require the development of stent manufacture, drug pharmacology and coating technology. We have worked on a system that integrates electrophoretic deposition (EPD) technology with the polymeric nanoparticles in DES for local drug delivery and a controlled release system. The surface morphology and drug loading amount of DES by EPD have been investigated under different operational conditions, such as operation time, voltage and the composition of media. We prepared poly-D,L-lactide-co-glycolic acid (PLGA) nanoparticles embedded with curcumin, which was done by a modified spontaneous emulsification method and used polyacrylic acid (PAA) as a surfactant because its carboxylic group contribute negative charge to the surface of CPNPs (?53.5 ± 5.8 mV). In the process of ‘trial and error' endeavors, we found that it is easy to control the drug loading amount deposited onto the stent while keeping uniform surface morphology. Accordingly, stent coating by EPD has a wide application to the modification of DES using various kinds of nanoparticles and drugs.

The clinical Experience of Tracheal Stenosis (기관협착의 임상적 고찰)

  • 명창률
    • Journal of Chest Surgery
    • /
    • v.27 no.2
    • /
    • pp.136-139
    • /
    • 1994
  • Tracheal stenosis is relatively common complication after tracheal intubation or tracheostomy for a long time. We experienced 10 cases of tracheal stenosis with various causes, prolonged intubation or tracheostomy caused the tracheal stenosis in seven, one after advanced cancer of the lung, one after inhalation burn, and the other was palliative management for tracheal stenosis by Gianturco type tracheal stent. We tried to correct this stenosis applying three tracheal stent and one Montgomery T-tube as a palliative approach, but failed in two, one restenosis due to regrowing of granulation tissue with scarring or another metastatic spread of cancer to systemic organs after 3 months of placing the stent. Tracheal circumferential resection and end to end anastomosis were done in seven, and obtained one postoperative complication as subglottic stenosis was followed by Montgomery T-tube and reoperation later. With the brief review of references, we report the cases.

  • PDF

Retrievable Nitinol Stent for Treatment of Tuberculous Tracheobronchial Stenosis -A case report- (결핵성 기관-기관지 협착에서 제거형 니티놀 스텐트 삽입요법 -1례-)

  • Chung, Bong-Kyu;Kim, Kwang-Taik;Park, Sung-Min;Sun, Kyung;Kim, Hyoung-Mook;Lee, In-Sung
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.107-111
    • /
    • 2000
  • Although a tracheal stent can be an option for inoperable tracheal stenoses there still are some troublesome side effects including overgranulation from foreign body irritation restenosis and patient's discomfort associated with the procedure. We report a successful case of a retrievable stent made of self-expandable 'shape memory' metal and polyurethane in a 24 year old female patient with respiratory distress and tight stenosis in the trachea and left main bronchus, The stent was inserted following a balloon dilatation and was successfully removed on the 7th days after the procedure. She regained a normal active life without any repiratory symptoms and a follow-up of 8 months showed satisfactory results.

  • PDF

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

Material Design and Analysis of Coronary Artery Stents (관상동맥혈관용 스텐트의 구조해석과 재료설계)

  • Park, Joong-Gwun;Kang, Tae-Won;Lee, Kee-Sung;Kim, Tae-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.7
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

Improved Biocompatibility of Intra-Arterial Poly-L-Lactic Acid Stent by Tantalum Ion Implantation : 3-Month Results in a Swine Model

  • Kim, Kangmin;Park, Suhyung;Park, Jeong Hwan;Cho, Won-Sang;Kim, Hyoun-Ee;Lee, Sung-Mi;Kim, Jeong Eun;Kang, Hyun-Seung;Jang, Tae-Sik
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.853-863
    • /
    • 2021
  • Objective : Biodegradable poly-L-lactic acid (PLLA) with a highly biocompatible surface via tantalum (Ta) ion implantation can be an innovative solution for the problems associated with current biodegradable stents. The purpose of this study is to develop a Taimplanted PLLA stent for clinical use and to investigate its biological performance capabilities. Methods : A series of in vitro and in vivo tests were used to assess the biological performance of bare and Ta-implanted PLLA stents. The re-endothelialization ability and thrombogenicity were examined through in vitro endothelial cell and platelet adhesion tests. An in vivo swine model was used to evaluate the effects of Ta ion implantation on subacute restenosis and thrombosis. Angiographic and histologic evaluations were conducted at one, two and three months post-treatment. Results : The Ta-implanted PLLA stent was successfully fabricated, exhibiting a smooth surface morphology and modified layer integration. After Ta ion implantation, the surface properties were more favorable for rapid endothelialization and for less platelet attachment compared to the bare PLLA stent. In an in vivo animal test, follow-up angiography showed no evidence of in-stent stenosis in either group. In a microscopic histologic examination, luminal thrombus formation was significantly suppressed in the Ta-implanted PLLA stent group according to the 2-month follow-up assessment (21.2% vs. 63.9%, p=0.005). Cells positive for CD 68, a marker for the monocyte lineage, were less frequently identified around the Ta-implanted PLLA stent in the 1-month follow-up assessments. Conclusion : The use of a Ta-implanted PLLA stent appears to promote re-endothelialization and anti-thrombogenicity.