• 제목/요약/키워드: In-plane Test

검색결과 1,250건 처리시간 0.028초

Ellipsometry에서의 Calibration 및 입사면 고정형 Ellipsometer (Calibration and a Plane of Incidence Fixed Ellipsometer)

  • 경재선;오혜근;안일신;김옥경
    • 반도체디스플레이기술학회지
    • /
    • 제2권4호
    • /
    • pp.23-26
    • /
    • 2003
  • The general users find difficulties in using ellipsometers. Thus, the object of this study is to construct an ellipsometer with simple operation principle. We developed an ellipsometer which does not require alignment and calibration before measuring sample. A basis structure model after rotating a compensator spectroscopic ellipsometry, the fixed incidence angle at $70^{\circ}$. This ellipsometer does not demand calibration, because the plane of incidence is not changed due to the novel sample holder structure. The results for various standard samples were compared with those from conventional RCSE to test the performance of this instrument. Also repeated measurements were performed to test the precision of the calibration coefficient in a plane of incidence fixed.

  • PDF

Multiloop edgewise Archwire 기법으로 치료된 전치 개교 증례의 두부방사선사진 계측학적 평가 (A CEPHALOMETRIC EVALAUATION OF ANTERIOR OPENBITE MALOCCLUSIONS TREATED BY MULTILOOP EDGEWISE ARCHWIRE TECHNIQUE)

  • 문성철;장영일
    • 대한치과교정학회지
    • /
    • 제23권4호
    • /
    • pp.565-606
    • /
    • 1993
  • The purpose of this study was to evaluate the change of before and after treatment of anterior openbite malocclusions treated by Multiloop Edgewise Archwire technique. The openbite sample consisted of 4 male and 12 female adults, treated with nonextraction or third molar extraction. The normal sample consisted of 58 subjects, which have pleasing facial profile and normal occlusion and no experience of orthodontic or prosthodontic treatment. The 58 subjects of normal sample were subdivided by cephalemetric vertical relationship of face. The 40 subjects, cephalometric vertical relationship of face was in normal range, classified as Normal Sample group 1. The 18 subjects, increased cephalometric vertical relationship of face, classified as Normal Sample group 2. The computerized cephalometric analysis was accomplished with 50 reference points for 22 skeletal measurements, 46 dentoalveolar measurements, 8 soft tissue measurements. Statistical analysis of the data was carried out with paired t-test, Student's t-test, and DUNCAN test using SAS(PC version), The results were as follows : 1. There were no statistically significant differences in skeletal measurement between before and after treatment. The major changes were in dentoalveolar region. 2. After treatment, the long axis of maxillary and mandibular posterior teeth were distally tipped-back, and uprighted to bisected occlusal plane. The interincisal angle was increased. 3. There were no statistically significant increase in the upper posterior dental height and statistically significant decrease in the lower posterior dental height. The upper anterior dental height was increased, but there was no statistically significant increase in the absolute upper anterior dental hight. The lower anterior dental height was increased. 4. After treatment, the maxillary occlusal plane to palatal plane angle and the mandibular occlusal plane to mandibular plane angle were statistically significant increased. Then, there were no statistically significant difference between after treatment group and normal sample group 2. 5. After treatment, the percentage of upper lip length to upper anterior dental height was decreased. Then, There were no statistically significant difference between after treatment group and normal sample group 2.

  • PDF

NC선반의 직선 사이클 평면 위치결정 정도 측정에 관한 연구 (A Study on Measurement of Linear Cycle Plane Positioning Accuracy of NC Lathe)

  • 김영석;송인석;정정표;한지희;윤원주
    • 한국공작기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.53-58
    • /
    • 2003
  • It is very important to measure linear cycle plane positioning accuracy of NC lathe as it effects all other parts of machines machined by them in industries. If the plane positioning accuracy of NC lathe is bad, the dimension accuracy and the change-ability of works will be bad in the assembly of machine parts. In this paper, computer software systems are organized to measure linear cycle plane positioning displacement of ATC(Automatic tool changer) on zx plane of NC lathe using two linear scales. And each sets of error data obtained from the test is descriptions to plots and the results of linear cycle plane positioning errors are expressed as nutriments by computer treatment.

Thermomechanical Properties of Thermal-Stress Relief Type of Functionally Gradient Materials

  • Watanabe, Ryuzo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 1993년도 추계학술강연 및 발표대회강연 및 발표논문 초록집
    • /
    • pp.2-2
    • /
    • 1993
  • The present status of the thennomechanica1 evaluation of functionally gradient materials(FGMs) for space plane application was reviewed, in which research activities and the cooperation of the national project team organized to study FGM science were demonstrated. The project team was divided into three working groups; de singing, processing and evaluation, each of which had their own tasks in the project cooperation. The testings details of the various thennomechanical tests for the FGM samples fabricated by the processing groups were described, along with their corresponding heating conditions of the real environments in the space plane application. For small-sized samples, laser beam heating test and burner heating test were well applied to study the heat shielding and heat resisting properties. Arc-heated wind tunnel test and high temperature!high velocity gas flow test were used for large-sized panel assemblies having cooling structures. The criteria for the evaluation of the heat shielding and heat resisting properties of the FGMs, as well as a crack activation mechanism in their differential temperature heating, were proposed on the basis of the observation in the burner heating test.

  • PDF

입방체형 삼축시험에 의한 다짐화강토의 전단강도 특성 (Strength Characteristics of Decomposed Granite Soil in Cubical Triaxial Test)

  • 정진섭;김찬기;박승해;김기황
    • 한국농공학회지
    • /
    • 제38권6호
    • /
    • pp.64-73
    • /
    • 1996
  • The three-dimensional strength behavior of compacted decomposed granite soil was studied using cubical triaxial tests with independent control of the three principal stresses. All specimens were loaded under conditions of principal stress direction fixed and aligned with the directions of compacted plane. For comparable test conditions, the major principal strain and volume strain to failure were smallest when the major principal stress acted perpendicular to the compacted plane. The opposite extremes were obtained when the major principal stress acted parallel to the compacted plane. In cubical triaxial tests with same b values and with ${\theta}$ values in one of three sectors of the octahedral plane, independent of the range of ${\theta}$, higher friction angles are obtained in tests with b greater than in triaxial compression tests in which b 0.0, Comparison between the results of the drained cubical triaxial tests on lksan compacted decomposed granite soil and the cross section of the Mohr-Coulomb failure surface as well as the cross section of the Mohr-Coulomb failure surface were made. Lade's isotropic failure criterion based on vertical specimens overestimates the strengths for tests performed with values of 0 between 90˚ and 1 50˚ the Mohr-Coulomb criterion generally underestimates the strengths of tests performed with values of ${\theta}$ between $0^{\circ}$ and $180^{\circ}$ except around the $120^{\circ}$.

  • PDF

철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구 (A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection)

  • 황경민;이경진;이종보;원덕희
    • 대한토목학회논문집
    • /
    • 제32권5A호
    • /
    • pp.267-275
    • /
    • 2012
  • 본 연구에서는 철근 콘크리트 벽과 강판 콘크리트 벽이 이질접합 형태로 만나는 구조물의 휨 및 전단거동 특성을 검토하기 위하여 L형과 I형 타입의 실험체를 제작하고 구조실험을 수행하였다. 실험 시, 지진하중 등에 대한 실험체의 동적특성을 확인하기 위하여 Push 및 Pull을 반복하는 싸이클 하중을 구현하고자 하였다. L형 실험체에 대한 면외 휨 실험결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, 강판 콘크리트 벽 내에 수평철근의 배근 유무를 변수로 구성한 두 개의 I형 실험체에 대한 면내 전단 실험결과, 수평철근의 배근 유무에 상관없이 공칭강도를 초과하는 전단 성능을 보였다.

관성측정장치를 이용한 경추관절 가동범위 측정의 검사 내 반복성 및 검사-재검사 신뢰도 연구 (Test-retest Reliability and Intratest Repeatability of Measuring Cervical Range of Motion Using Inertial Measurement Unit)

  • 김현호;김경욱;박지민;김은석;이민준;강중원;이상훈;박영배
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.25-33
    • /
    • 2013
  • Objectives : To assess the test-retest reliability and the intratest repeatability in measuring the cervical range of motion of healthy subjects with wireless microelectromechanical system inertial measurement unit(MEMS-IMU) system and to discuss the feasibility of this system in the clinical setting to evaluate the cervical spine musculoskeletal. Methods : 12 healthy people who were evaluated as no- or mild-disability with neck disability index were participated. Their cervical motion were measured with IMU twice in consecutive two days for the test-retest reliability study. Intratest repeatability was calculated in the two tests separately. The calculated intraclass correlation coefficients(ICC) were discussed and compared with the those of the previous studies. Results : Cervical range of motion data were acquired and statistically processed: left rotation($61.64^{\circ}$), right rotation($65.12^{\circ}$), extension($61.98^{\circ}$), flexion($52.81^{\circ}$), left bending($39.31^{\circ}$), right bending($41.08^{\circ}$). ICCs were 0.77~0.98(intratest repeatability) and 0.74~0.93 (test-retest reliability) in the primary motion. In the coupling motion, intratest repeatability ICCs were 0.93~ 0.99(transverse primary plane), 0.88~0.97(saggital primay plane), and 0.77~0.93(coronal primary plane). Test-retest reliability of coupling motion were 0.90~0.97(transverse primary plane), 0.00~0.72(saggital primary plane), and 0.04~0.76(coronal primary plane). Conclusions : Several types of range-of-motion devices are now on use in many fields including medicine, but the practicality of the devices in clinical use is questionable for the convenient and economical aspects. In this study, we presented the reliability of cervical range of motion test with the developed wireless MEMS-IMU system and discussed its potential utility in clinical use.

LiDAR 데이터의 3D Hough 변환을 이용한 건물 지붕 평면의 세그멘테이션 및 정밀 평면방정식 추출 (The Segmentation and the Extraction of Precise Plane Equation of Building Roof Plane using 3D Hough Transformation of LiDAR Data)

  • 이영진;오재홍;신성웅;조우석
    • 한국측량학회지
    • /
    • 제26권5호
    • /
    • pp.505-512
    • /
    • 2008
  • LiDAR 점 데이터에서 3D Hough 변환을 이용하여 건물 지붕의 평면을 추출할 경우, 추출하고자 하는 평면에 포함되지 않는 LiDAR 점 데이터로 인하여 잘못된 평면이 추출될 수 있다는 문제점과, 누적배열에서 최대값을 갖는 누적배열인자가 여러 개 발생할 수 있다는 문제점이 발생할 수 있다. 본 논문에서는 최다평면(peak plane), 정확평면(exact plane), 최확평면(LESS plane)을 정의하고 이를 이용하여 위의 문제점들을 해결하는 방법을 제안하였다. 또한, 위의 문제점이 발생할 수 있는 데이터를 제작하여 본 논문에서 제안한 알고리즘을 테스트하였다.

Performance and functionality of SRI detector array and focal plane electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Chang, Young-Jun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.804-807
    • /
    • 2006
  • The SRI(Super Resolution Imager) with 800mm aperture primary mirror is the ground development model of the high resolution satellite camera. The SRI focal plane electronics including detector array generates the data for high-resolution images by converting incoming light into digital stream of pixel data. Since the focal plane including a detector is the basic building block of the camera system, the main system performances is directly determined by its performance. This paper measures the SRI focal plane electronics’ performance such as the dark signal, the dark signal noise, the linearity, the PRNU(Photo Response Non-Uniformity), the SNR(Signal to Noise Ratio) and the sensor saturation capability. In addition, this paper verifies the various functionalities of the SRI focal plane electronics. The electrical test equipment with the specialized software and the optical test equipments such as the integrating sphere, the rotation stage and the target are implemented and used to verify these functionalities and performances.

  • PDF

하이브리드 복합재료의 전단 물성치 측정에 관한 연구 (A study of the shear properties for hybrid composites)

  • 백운철;조맹효;황재석
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.96-99
    • /
    • 2002
  • In order to determine the in-plane shear properties of unidirectional carbon fiber reinforced aluminum laminate composites, a new Iosipescu shear test fixture was developed, by using a fixture undergoing tensile force for the specimen edge to be subjected to compressive loads assumption, under plane stress. Also, to compare the results, Iosipescu shear test method by the modified Wyoming fixture and the off-axis tensile test were performed to determine the shear properties. Off-axis tension test was performed by using new oblique-shaped tabs proposed by Sun and Chung. [5] The oblique tabs reduced remarkably end-constraint effects of off-axis specimens with a aspect ratio of about eight. It is observed through the experimental results show that there is no significant difference between off-axis test results and those of Iosipescu shear test.

  • PDF