• Title/Summary/Keyword: In-house power system

Search Result 216, Processing Time 0.031 seconds

A Study on the Soft Starting Switch of Single Phase Condenser Induction Motor Using TRIAC (트라이액을 이용한 단상 유도전동기의 Soft Starting Switch에 관한 연구)

  • 강응석;신대철;최종문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.97-103
    • /
    • 2004
  • In general the starting current of single phase induction motor is 3 to 6times of the rated current It make flickering an electric lamp, dispersion a TV screen, insulation destructing an electric motor and momentary blazing of house wiring. Thus it happens losing an electric power loss and reducing an efficiency and a life of home electrical apparatus. In this paper, we proposed the method of reducing staring current with 3.7(%) using TRIAC and ACCT(alternated current transformer) in order to improve the above problem And also we verified semipermanent system with using semiconductor element.

Study on the Development of Battery Energy Storage Device Using Mid night Power (축전식 심야전력기기의 개발에 관한 연구)

  • Kim, Ho-Yong;Kim, Jae-Eon;Rho, Dae-Seok;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.63-66
    • /
    • 1991
  • With the diversity of life patterns and the improvement of level in life which have been resulted from the economic development, people have showed the tendency to pursue the comfortable life as well as the home automation or intelligent house. Furthermore, the clean energy supply and management system have been introduced for the solution of environmental problem on earth and the effective utilization of energy. This study is to describe the battery energy storage device, which is one of the clean energy supply and management systems that are economically efficient in both sides of supply and demand. and able to solve the problem of energy crisis.

  • PDF

A Design of Line-fuse Melting Zone Using by Different Union Metal (이종접합 금속재료를 이용한 퓨즈 용단부의 설계)

  • Kim, D.K.;Youn, Y.J.;Park, Y.B.;Lee, S.H.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1525-1527
    • /
    • 1998
  • The line-fuse which one of device most widely used in distributed line system has a ability to cut off the fault current flow into the house. But this device can be used only one time. So there are many waste of human power and money to exchange acted line-fuse. In this paper, we designed new type of line-fuse melting zone using by different union metal, so line-fuse can be reused after once operated.

  • PDF

Decision making for CDMA HPA Bias used Fuzzy Logic Controller (퍼지제어기를 이용한 CDMA중계기의 최적동작점 결정)

  • 김성식;홍광진;조현찬;오창헌;김두용;이규영
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.05a
    • /
    • pp.283-286
    • /
    • 2003
  • Generally, the repeater in CDMA(Code Division Multiple Access) included HPA(HI-Power Amplifier) to amplifier communication signals. Also, HPA contained PD(Predistortor) to maintain the linearization of amplifier characteristics A configuration component of PD have been used electricity nonlinear devices such that diode. But this diode takes many influences at the circumstance temperature. Consequently, st can't maintain output linearization, and drop the communication Duality. The manufacturer set bias of the circuit to the manual at the first out of ware-house low. But the Q-point changes according to the change of the high temperature or low temperature. Therefore, we designed a system to maintain the Q-point by FDM(Fuzzy Decision Maker) in this paper.

  • PDF

Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.

Development of monitoring system for demonstration test of solar energy system (태양에너지 시스템의 실증시험을 위한 모니터링 시스템 개발)

  • Yang, Dong-Jo;Kim, Jae-Yeol;Oh, Yool-Kwon;Kim, Jin-Heung;Chung, Nak-Kyu;Cho, Guem-Bae
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.723-726
    • /
    • 2005
  • The application of solar energy, in the field of alternative energy, was on the increase tendency. In the case of advanced nations, through continuous R&D, solar hot water heater with high efficiency has been used for the house and the industrial process on business, advanced nations were reached up the experimental stage of solar generation system. But, the actual circumstance of the domestic has been not accomplished the popularization of solar hot water heater and the settlement of it which is the fundamental stage of the solar energy usage. This trouble, the domestic was flooded with small enterprise for producing solar hot water heater, was caused by the popularization and the production without verification of performance. To supply the monitoring program for evaluating solar hot water heater, this research was purpose to improve the technical development of the enterprise for producing solar-heat hot-water-boiler and served as an aid for the enlargement and the popularization on solar energy.

  • PDF

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

Effects of Pipe Network Materials and Distance on Unused Energy Source System Performance for Large-scale Horticulture Facilities (배관 재질 및 길이에 따른 대규모 시설원예단지용 미활용 에너지 시스템의 성능 평가)

  • Lee, Jae-Ho;Yoon, Yeo-Beom;Hyun, In-Tak;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.119-125
    • /
    • 2014
  • This study investigated the effects of pipe network materials and distance on system performance utilizing unused energy sources in large-scale horticulture facility. For this, the modeling was performed with a 100 m long and 100 m wide rectangular shaped glass house having an area of 1ha ($10,000m^2$) using EnergyPlus software. The heat sources considered were air source, geothermal heat, power plant waste heat, sea water heat, and river water. The temperature variation of the fluid with regard to pipe material and distance from the heat source and the resultant heat pump electricity consumptions were calculated. It turned out that the fluid temperature reaching the heat pump increased as the distance from the heat source increased in case of sea water and river water, which have higher temperatures than the surrounding soil, improving the heat pump efficiency. It was vice versa in case of the power plant waste heat. In addition, pipe material of PVC showed the smallest effect on the system performance variation due to the lowest thermal conductivity, compared to PB and HDPE.

Studies on the Rubber House for the Use of a Power Sprayer (동력분무기용 고무호오스에 관한 연구)

  • 고학균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.3
    • /
    • pp.2697-2702
    • /
    • 1972
  • Controlling insects and diseases is an important factor for increasing yields of agricultural products. Power sprayer is widely used in cooperative controlling of insects and diseases for the production of rice and fruits. However, farmers need a long hose to use the power sprayer and that presently most of the farmers have hose made abroad. This study was designed to test the change of outside diameter and unit Iength, and to measure the pressure Ioss for three different kinds of hoses made domestically and one made in Japan. The resulte are as follows; 1. The three kinds of Korean-made hoses showed an increase in the length and a decrease in the outside diameter as the spraying pressure increase. The rate of change of the length ranged from 3.5% to 1.6% and the rate of change of the outside diameter from 3.5% to 1.4% respectively. 2. As the length of hose increases, the pressure loss was $3kg/cm^2$ at the end of a 100m of the hose made in Japan, while it was $7-10kg/cm^2$ for Korean-made hoses. 3. The Korean-made hoses were not broken under $27-28kg/cm^2$ of spraying pressure. 4. As a conclusion, the Korean-made hoses can safely be used under continuous rated pressure of the power sprayer, but they can not properly be used for the case of cooperative controlling system where a long hose is reguired because of the heaviness of the hoses and the narrowness of the inside diametar. Hence, it is highly recommended to improve the Korean-made hoses to be used for such a situation.

  • PDF

A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction (온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구)

  • Lee, Wongoo;KIM, Kang-Won;KIM, Balho H.
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2016
  • ESS(Energy Storage System) is an important source that keeps power supply stable and utilizes electricity efficiently. For example, ESS contributes to resolve power supply imbalance, stabilize new renewable energy output and regulate frequency. ESS is predicted to be expanded to 55.9GWh of installed capacity by 2023, which is 30 times more than that of 2014. To raise competitiveness of domestic ESS industry in this increasing world market, we have disseminated load-shift ESS for continuous power supply imbalance with FR ESS, and also necessity to secure domestic track record is required. However in case of FR ESS, utility of installing thermal power plant is generally generated within 5% range of rated capacity, so that scalability of domestic market is low without dramatic increase of thermal power plant. Necessity of load-shift ESS dissemination is also decreasing effected by surplus backup power securement policy, raising demand for new dissemination model. New dissemination model is promising for $CO_2$ reduction effect in spite of intermittent output. By stabilizing new renewable energy output in connection with new renewable energy, and regulating system input timing of new renewable energy generation rate, it is prospected model for 'post-2020' regime and energy industry. This research presents a policy alternatives of REC multiplier calculation method to induce investment after outlining PV-connected ESS charge/discharge mode to reduce GHG emission, This alternative is projected to utilize GHG emission reduction methodology for 'Post-2020' regime, big issue of new energy policy.