• Title/Summary/Keyword: In-grid Condition

Search Result 592, Processing Time 0.026 seconds

Performance Test of MGT Combined Heat & Power System (마이크로 가스터빈 열병합 발전시스템 성능평가)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.313-316
    • /
    • 2006
  • As Decentralized Generation(DG) becomes more reliable and economically feasible, it is expected that a higher application of DG units would be interconnected to the existing grids. This new market penetration of DG technologies is linked to a large number of factors like technologies costs and performances, interconnection issues, safety, market regulations, environmental issues or grid connection constrains. Korea Electric Power Corporation (KEPCO) has researched performance characteristics of the 60k W class 1) basic start-up & shutdown operation analysis 2) interconnection test 3) MGT -absorption chiller-heater system in the local condition. Variations of heat recovery from exhaust gas has measured according to micro gas turbine output of 15, 30, 45, 60kW. From those results, the performance of the MGT-absorption chiller/heater system has been evaluated. The suggested strategy and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

A Numerical Study on the Extinction of Methane/Air Counterflow Premixed Flames (대향류 메탄/공기 예혼합화염의 소염특성에 관한 수치해석적 연구)

  • 정대헌;정석호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1982-1988
    • /
    • 1995
  • Methane/Air premixed flames are studied numerically, using a detailed chemical model, to investigate the flame strech effects on the extinction in a counterflow. The finite difference method, time integration and modified Newton iteration are used, and adaptive grid technique and grid smoothing have been employed to adjust the grid system according to the spatial steepness of the solution profiles. Results show that the flame stretch, or the conventional nondimensionalized stretch having the tangential flow characteristics of the stretched flame alone cannot adequately describes the extinction phenomena. On the other hand, the local flame stretch having both the normal and tangential flow characteristics of the stretched flame can give a proper explanation to the extinction of the symmetric planar premixed flames stabilized in a counter flow. The extinction condition were found to be a constant local stretch regardless of the equivalence ratio.

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

Statistical Reliability Analysis of Numerical Simulation for Prediction of Model-Ship Resistance (선체 저항에 대한 수치 해석의 통계적 신뢰도 분석)

  • Lee, Sang Bong;Lee, Youn Mo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.321-327
    • /
    • 2014
  • A wide scope of numerical simulations was performed to predict model-ship resistances by using STAR-CCM+ and OpenFOAM. The numerical results were compared with experimental measurements in towing tank to analyze statistical reliability of the present simulations. Based on the normal distribution of resistance errors in 113 cases of container carriers, tankers and very large crude-oil carriers, the confidence intervals of numerical error were estimated as [-2.64%,+2.32%] and [-1.82%, +1.87%] with 95% confidence in STAR-CCM+ and OpenFOAM, respectively. The resistance errors of liquefied natural gas carriers with single- and twin-skeg were confident in the ranges of [-2.51%,+2.64%] and [-2.29%, +1.46%], respectively. The grid uncertainty of resistance coefficients for KCS was also quantitatively analyzed by using a grid verification procedure. The grid uncertainty of OpenFOAM (5.1%) was larger than 4.4% uncertainty of STAR-CCM+ although OpenFOAM provided statistically more confident results than those of STAR-CCM+. It means that a grid system verified under a specific condition does not automatically lead to statistical reliability in general cases.

Optimization of a Nuclear Fuel Spacer Grid Spring Using Homology (호몰로지 설계를 이용한 원자로 핵연료봉 지지격자 스프링의 최적설계)

  • Lee Jae-Jun;Song Ki-Nam;Park Gyung-Jin
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.828-835
    • /
    • 2006
  • Spacer grid springs support the fuel rods in a nuclear fuel system. The spacer grid is a part of a fuel assembly. Since a spring has repeated contacts with the fuel rod, fretting wear occurs on the surface of the spring. Design is usually performed to reduce the wear. The conceptual design process for the spring is defined by using the Independence of axiomatic design and the design is carried out based on the direction that the design matrix indicates. For detailed design an optimization problem is formulated. In optimization, homologous design is employed to reduce fretting wear. The deformation of a structure is called homologous if a given geometrical relationship holds for a given number of structural points before, during, and after the deformation. In this case, the deformed shape of the spring should be the same as that of the fuel rod. 1bis condition is transformed to a function and considered as a constraint in the optimization process. The objective function is minimizing the maximum stress to allow a local plastic deformation. Optimization results show that the contact occurs in a wide range. Also, the results are verified by nonlinear finite element analysis.

  • PDF

The Quantitative Evaluation of Aging State of Field Composite Insulators Based on Trap Characteristics and Volume Resistivity-Temperature Characteristics

  • Liang, Ying;Gao, Li-Juan;Dong, Ping-Ping;Gao, Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1355-1362
    • /
    • 2018
  • In order to obtain a better understanding of the ageing process of the field composite insulators, it is necessary to explore a quantitative-valuation method for the aging state evaluation. And the linear relationship between volume resistivity and temperature is proposed. In this paper, the composite insulators with different lengths of operating lives from two manufacturers were tested. The relationship between trap characteristics and volume resistivity-temperature characteristics were analyzed based on Thermal Stimulated Current (TSC), volume resistivity-temperature test, Scanning Electron Microscope (SEM) and Fourier Transform Infrared Spectroscopy (FTIR). Furthermore, the application of trap characteristics in the quantitative evaluation of aging state of composite insulators was discussed. The results showed that there was a general negative correlation between the relative variation ratio of trap charges and the volume resistivity-temperature characteristics. Meanwhile, the physicochemical properties would change with the aging time, which would result in the increasing of electron traps. Combined with the TSC and volume resistivity test results, the trap characteristic thresholds which indicated the serious age of the composite insulators had been proposed.

A Study on the Transient Operation Algorithm in Micro-grid based on CVCF Inverter (CVCF 인버터 기반의 Micro-grid에 있어서 과도상태 운용알고리즘에 관한 연구)

  • Lee, Hu-Dong;Choi, Sung-Sik;Nam, Yang-Hyun;Son, Joon-Ho;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.526-535
    • /
    • 2018
  • Recently, in order to reduce the $CO_2$ emission in the island area, countermeasures to operate power system in a stable manner are being researched due to decrease of the operation rate in diesel generators and the increase of renewable energy sources. The phenomenon of energy sinking can be occurred if the output of renewable energy sources is larger than customer loads. Voltage of CVCF(constant voltage & constant frequency) battery could be increased rapidly according to the condition of SOC(state of charge) and blackout could be occurred due to shut-down of CVCF inverter, at carbon free island micro-grid based on the CVCF inverter. In order to overcome these problems, this paper proposes a transient operation algorithm in CVCF based micro-grid which in advance prevents shut-down of CVCF inverter during the energy sinking. And also this paper proposes the modeling of micro-grid including CVCF inverter, PV system, customer load using PSCAD/EMTDC S/W. From the results of micro-grid modeling based on the proposed algorithm, it is confirmed that CVCF based micro-grid can properly prevent shut-down of CVCF inverter according to SOC and battery voltage of CVCF inverter when energy sinking is occurred.

An Experiment on Scattered-ray Content Ratio and Skin Dose according to the Exposure Condition for Chest Radiography (흉부 X선촬영조건의 변화에 따른 산란선 함유율과 피부선량에 관한 연구)

  • Park, Young-Sun;Ahn, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.3-9
    • /
    • 1992
  • In an experiment using chest radiography, the authors measured the scattered ray content ratio and exposed skin dose giving varieties to the object thickness, tube voltage, additional filters and gird. The result was as follows, In the 80 kV the required mAs for the density 1.8 was $10{\sim}20$ times as much as in the 140 kV, and when 10 : 1 grid was used the required mAs was $3{\sim}5$ times as much as when grid was not used. Under the same tube voltage the scattered ray content ratios were increased as the additional filter thickness became thicker. And when 10 : 1 grid was used the ratio could be decreased $2{\sim}5$ times as much as when grid was not used. Skin doses exposed to the patients were increasing as the thickness of the object became thicker, and were decreasing as filters became thicker while showing slow the decreasing effects above the 1/8 VL. And when the grid was used skin doses were increased $2{\sim}4$ times as much as when not used. In order to improve the image qualities while reducing the exposures in the chest radiography, the authors suggest followings. The additional filters up to the 1/2 VL will be suitable according to the thickness of the objects in the 80kv, while the 10 : 1 grid and additional filter of 1/8 VL will be suitable in the 140 kV.

  • PDF

Grid-Connected Photovoltaic System Applying the Step Variable MPPT Control and DVR (Step 가변형 MPPT 제어기법과 DVR을 적용한 계통연계형 태양광 발전 시스템)

  • Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.42-49
    • /
    • 2012
  • Grid-connected photovoltaic generator system requires high performance PCS(Power Conditioning System) according to the standard of 'Distributed Generation Grid-Connected Technology Standards'. This paper presents the MPPT control method which improves output efficiency through fast tracking to the maximum power point of PV and a reduced self-excited vibration. Secondly, in this paper DVR function was applied to PCS to compensate the voltage sag frequently happening for a power system. The proposed PCS control is analyzed and compared to conventional PCS operating characteristic, the various insolation and loads, and voltage sag condition through PSIM tool. It proves the utility.

Noise Reduction of Blade Vortex Interaction Using Tip Jet Blowing

  • Yang Choongmo;Baek Jehyun;Saito Shigeru;Aoyama Takashi
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.172-174
    • /
    • 2003
  • Nnumerical investigations of the tip vortical characteristics were conducted with lateral tip blowing to reduce Blade-Vortex Interaction (BVI) noise. The predictions of BVI noise were performed using a combined method of an unsteady Euler code with an aeroacoustic code based on Ffowcs- Williams and Hawkings formulation. A moving overlapped grid system with three types of grids (blade grid, inner and outer background grid) was used to simulate BVI of helicopter with two OLS-airfoil blades in forward/ descending flight condition. The calculated waveform of BVI noise, which is characterized by the distinct peaks caused during blade vortex interaction, clearly shows the effect of lateral blowing at tip to reduce BVI noise

  • PDF