• Title/Summary/Keyword: In-Situ NaI 검출기

Search Result 4, Processing Time 0.02 seconds

MDA Assessment of NaI(Tl), LaBr3(Ce), and CeBr3 Detectors for Freshly Deposited Radionuclides on the Soil (지표면 침적 방사성핵종에 대한 NaI(Tl), LaBr3(Ce) 및 CeBr3 검출기의 MDA 비교 평가)

  • Lee, Jun-Ho;Kim, Bong-Gi;Lee, Dong Myung;Byun, Jong-In
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.321-328
    • /
    • 2019
  • The detection performances of the NaI(Tl), $LaBr_3$(Ce) and $CeBr_3$ scintillation detectors, which can be used to rapidly evaluate the major artificial radionuclides deposited on the soil surface in a nuclear accident or radiological emergency, were compared. Detection performance was assessed by calculating the minimum detectable activity (MDA). The detection efficiency of each detector for artificial radionuclides was semi-empirically determined using mathematical modelling and point-like sources having certified radioactivity. The background gamma-ray energy spectrum for MDA evaluation was obtained from relatively wide and flat grassland, and the MDA values of each detector for the major artificial radionuclides that could be released in nuclear accidents were calculated. As a result, the relative MDA values of each detector regarding surface deposition distribution at normal environmental radiation level were evaluated as high in the order of the NaI(Tl), $LaBr_3$(Ce), and $CeBr_3$ detectors. These results were compared based on each detector's intrinsic and measurement environment background, detection efficiency, and energy resolution for the gamma-ray energy region of the radionuclide of interest.

Study on the Dosimetry and Assessment of Terrestrial Radiation Exposure (지각 방사선에 의한 피폭선량측정 및 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.87-100
    • /
    • 1990
  • For the quantitative evaluation and assessment of radiation exposure from terrestrial component of natural environmental radiation, successive thermoluminescence dosimetry and periodical in-situ gamma ray spectrometry were carried out for a period of 24 months. LiF PTFE dise TLDs and $3&{\phi}{\times}3'$cylindrical NaI(Tl)scintill ation detector in association of portable multichannel analyzer (4096 ch) were used in this study. The doses measured were evaluated and assessed in terms of effective dose equivalent. As a concomitant output, the dose equivalent due to ionizing component of cosmic ray was able to be evaluated. According to the results obtained in terms of variance weighted mean, the annual effective dose equivalents of terrestrial gamma ray and cosmic ray ionizing component in Taejeon area came out to be $564{\pm}4\;{\mu}Sv(64.8{\pm}0.5nSv{\cdot}h^{-1}$ and $300{\pm}2\;{\mu}Sv(34.3{\pm}0.2nSv{\cdot}h^{-1}$, respectively, which are reasonable comparably with that appeared in UNSCEAR Report[28]as per caput annual effective dose equivalent in 'areas of normal background radiation'.

  • PDF

Assessment of Natural Radiation Exposure by Means of Gamma-Ray Spectrometry and Thermoluminescence Dosimetry (감마선분광분석(線分光分析) 및 열형광검출법(熱螢光檢出法)에 의한 자연방사선(自然放射線)의 선량측정연구(線量測定硏究))

  • Jun, Jae-Shik;Oh, Hi-Peel;Choi, Chul-Kyu;Oh, Heon-Jin;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.2
    • /
    • pp.96-108
    • /
    • 1985
  • A study for the assessment of natural environmental radiation exposure at a flat and open field of about $10,000m^2$ in area in CNU Daeduk campus has been carried out by means of gamma-ray scintillation spectrometry and thermoluminescence dosimetry for one year period of time from October 1984. The detectors used were 3'${\phi}{\times}$3' NaI(T1) and two different types of LiF TLD, namely, chip sealed in plastic sheet which tightly pressed on two open holes of a metal plate and Teflon disk. Three 24-hour cycles of in-situ spectrometry, and two 3-month and one 1-month cycles of field TL dosimetry were performed. All the spectra measured were converted into exposure rate by means of G(E) opertaion, and therefrom exposure rate due to terrestrial component of environmental radiation was figured out. Exposure rate determined by the spectrometry was, on average, $(10.54{\pm}2.96){\mu}R/hr$, and the rates of $(12.0{\pm}3.4){\mu}R/hr$ and $(11.0{\pm}3.6){\mu}R/hr$ were obtained from chip and disk TLD, respectively. Fluctuations in diurnal variation of the exposure rate measured by the spectrometry were noticeable sometime even in a single cycle of 24 hours. It is concluded that appropriately combined use of TLD with iu-sitn gamma-ray spectrometry system can give more accurate and precise measure of environmental radiation exposure, and further study for more adequate and sensitive TLD for environmental dosimetry, including improvement and elevation of accuracy in data assessment through inter-laboratory or international intercomparison is necessary.

  • PDF